1. Important Safety Instructions
- ⚠️ Please mind potential fire risk and strictly follow the instruction manual for charging and storage.
- This charger can only charge cylindrical lithium-ion batteries and nickel-metal hydride batteries; do not charge lithium iron phosphate batteries.
- Before use, carefully refer to this manual and ensure the charging current does not exceed the recommended value for rechargeable batteries.
- Do not use other power adapters.
- The charger may generate heat during charging and discharging. Avoid burns.
- When not in use, unplug the power and remove the battery.
- It can only be used in normal indoor settings.
- The test data of this product is for reference only. For actual conditions, please refer to professional instruments.
2. Product Overview
Thank you for choosing the LiitoKala Lii-500 Smart Charger. This high-end device offers advanced functionalities for efficient and safe battery management.
Key Features:
- 4-channel independent charging
- Battery capacity detection (Fast Test & Normal Test)
- Internal resistance monitoring
- Multiple protections: Anti-reverse connection, short-circuit, overcharge, temperature control, voltage restriction (1.65V-2.2V)
- USB 5V output (power bank function)
- Zero-voltage activation
- Real-time monitoring of battery status on LCD display
- Compatible with various cylindrical lithium-ion and nickel-metal hydride batteries (e.g., 18650, 26650, AA, AAA)


3. Package Contents
- 1 x LiitoKala Lii-500 Smart Charger Unit
- 1 x 12V/2A Power Adapter
- 1 x User Manual (This document, also available as PDF: View PDF)
4. Setup
4.1 Connecting Power
- Connect the provided 12V/2A power adapter to the 'DC: 12V' input port on the side of the charger.
- Plug the power adapter into a standard electrical outlet.

4.2 Initial Power-On
Upon connecting the power, all segments of the LCD screen will briefly light up, indicating the charger is ready for use.
4.3 External View Diagram

5. Operating Instructions
5.1 Key Description
- MODE Button: Used to select the operating mode (CHARGE, FAST TEST, NOR TEST). Press and hold for 3 seconds to switch between modes.
- CURRENT Button: Used to select the charging or discharge current (300mA, 500mA, 700mA, 1000mA).
- 1, 2, 3, 4 Buttons: These buttons correspond to each independent charging channel. They are used to select a specific channel for individual settings or to view detailed data for that channel.
5.2 Inserting Batteries
- Ensure the charger is powered on.
- Insert compatible cylindrical lithium-ion (3.7V) or nickel-metal hydride (Ni-MH/Ni-Cd) batteries into any of the four slots.
- Observe the correct polarity (+ and -) as indicated in the battery slots.
- If no battery is inserted or a faulty battery is detected, the LCD will display 'Null'.

5.3 Charging Mode (CHARGE)
- After inserting a battery, the charger will automatically measure its internal resistance (approx. 3 seconds) and then enter CHARGE mode.
- The default charging current is 500mA. Within 8 seconds of battery insertion, you can press the CURRENT button to select your desired charging current (300mA, 500mA, 700mA, or 1000mA). If no selection is made, it will default to 500mA.
- Each channel operates independently. You can set different charging currents for different batteries or mix battery types.
- To view detailed information (Voltage, Current, Time, Capacity, Internal Resistance) for a specific channel, press its corresponding button (1, 2, 3, or 4).
5.4 Capacity Detection Modes
The Lii-500 offers two modes to test battery capacity:
5.4.1 FAST TEST (Rapid Capacity Testing Mode)
This mode quickly determines battery capacity through a discharge-then-charge cycle.
- After inserting batteries, press the MODE button within 8 seconds to select 'FAST TEST'.
- Press the CURRENT button to select the desired charging current (300mA, 500mA, 700mA, or 1000mA).
- The charger will first discharge the battery. The discharge current is 250mA for selected charging currents of 300mA/500mA, and 500mA for 700mA/1000mA.
- After discharge, the battery will be fully charged, and the recorded charge quantity will be displayed as the battery's capacity.
5.4.2 NOR TEST (Normal Capacity Testing Mode)
This mode provides a more accurate capacity measurement through a charge-discharge-charge cycle.
- After inserting batteries, press the MODE button within 8 seconds to select 'NOR TEST', or press and hold the MODE button for 2 seconds in any state to enter NOR TEST mode.
- Press the CURRENT button to select the desired charging current (300mA, 500mA, 700mA, or 1000mA).
- The charger will first fully charge the battery, then discharge it, recording the discharge capacity. Finally, it will fully recharge the battery. The recorded discharge capacity is the battery's measured capacity.
5.5 USB 5V Output (Power Bank Function)
The Lii-500 can function as a power bank to charge external USB devices.
- Ensure at least one 3.7V lithium-ion battery is inserted into any slot. (Ni-MH batteries are not supported for USB output).
- Connect your USB device (e.g., smartphone, tablet) to the 'OUT: 5V' USB port on the side of the charger.
- The charger will provide a 5V/1000mA output.
- Note: The USB output function is active only when the charger is not connected to its own power adapter.

6. Maintenance
- Keep the charger clean and dry. Use a soft, dry cloth to wipe the surface.
- Avoid exposing the charger to extreme temperatures, direct sunlight, or high humidity.
- Unplug the charger from the power outlet when not in use for extended periods.
- Do not attempt to disassemble or modify the charger, as this will void the warranty and may cause damage or injury.
7. Troubleshooting
- LCD displays 'Null': This indicates either no battery is inserted, or a faulty/incompatible battery has been placed in the slot. Check battery type and condition.
- Charger gets warm during operation: It is normal for the charger to generate some heat during charging and discharging cycles. However, ensure proper ventilation and avoid covering the charger. If it becomes excessively hot, discontinue use and contact support.
- No USB 5V output: Ensure that at least one 3.7V lithium-ion battery is correctly inserted. Ni-MH batteries do not support the USB output function. Also, ensure the charger is not connected to its own power adapter when attempting to use the USB output.
- Charger not responding: Check if the power adapter is securely connected to both the charger and the power outlet. Try a different outlet if necessary.
8. Specifications
| Parameter | Value |
| DC Input Voltage | 12V/2.0A |
| Li-ion Charging Current | 4.2V, 300mA/500mA/700mA/1000mA |
| Ni-MH Charging Current | 1.48V, 300mA/500mA/700mA/1000mA |
| Compatible Batteries | 18650, 26650, 14500, AA, AAA, etc. |
| Discharge Current | 250mA, 500mA |
| USB Output | 5V/1000mA |
| Termination Method | Intelligent Voltage Monitoring |
| Dimensions (L x W x H) | 162mm x 96mm x 36mm |
| Output Power | ≤37.5W |
| Voltage Range | USB (5-20V DC) |
| Certifications | RoHs, CE, FCC, KC |
9. User Tips
- Battery Management: Utilize the 'FAST TEST' or 'NOR TEST' functions to determine the real capacity of your batteries. This helps in sorting and managing your battery collection effectively, ensuring you use cells with similar capacities together.
- Optimal Charging: For general charging, especially if you're not in a hurry, a 500mA current is often a safe and recommended choice to prolong battery life.
- Power Bank Use: When using the USB output function, always ensure you have 3.7V Li-ion batteries inserted for proper operation, as Ni-MH batteries are not supported for this feature.
10. Warranty and Support
For any warranty claims, technical support, or inquiries regarding your LiitoKala Lii-500 Smart Charger, please contact the seller or the manufacturer directly. Keep your purchase receipt as proof of purchase.