1. Introduction
Thank you for choosing the Tuya Zigbee Smoke Detector KRD001. This smart device is designed to provide reliable smoke detection and fire hazard alerts, integrating seamlessly with your Tuya-compatible smart home system. With remote monitoring capabilities and a loud alarm, it helps ensure the safety of your home or office.
For a detailed PDF version of this manual, please refer to the official user manual (PDF).
2. Safety Information
- This device is for indoor use only.
- Do not paint the smoke detector, as this may interfere with its proper operation.
- Test the smoke detector regularly as described in this manual.
- Keep the device clean and free from dust.
- Do not attempt to repair the device yourself; refer to qualified personnel.
- Ensure the battery is inserted correctly according to polarity markings.
3. Package Contents
Upon unboxing, please verify that all items are present:
- Tuya Zigbee Smoke Detector KRD001
- Mounting Screws and Wall Plugs
- User Manual (this document and/or a printed version)
- CR2 Battery (may be pre-installed or included separately)
Video: Unboxing and demonstration of the smoke detector's alarm function and physical features.
4. Product Overview
The Tuya Zigbee Smoke Detector KRD001 is a compact and intelligent device designed for early smoke detection. It features:
- Zigbee Connectivity: Seamless integration with Tuya smart home platforms via a Zigbee gateway.
- Remote Monitoring: Receive alerts and monitor status via the mobile app.
- Acoustooptic Alarm: Emits a loud audible alarm (85-95dB) and flashes an LED light upon smoke detection.
- Low Power Reminder: Notifies you when the battery is low.
- Mute Function: Allows temporary silencing of the alarm via the app.
- Self-Test Button: For regular functional checks.

Image: The Tuya Zigbee Smoke Sensor highlighting remote monitoring, microparticle detection, low power reminder, and mute function.
5. Specifications
| Feature | Specification |
|---|---|
| Model Number | KRD001 |
| Wireless Connection | Zigbee (2.4G) |
| Operation Voltage | DC3V |
| Battery Type | CR2 |
| Battery Life | Approximately 3 years |
| Operation Temperature | -10°C to +50°C |
| Alarm Sound Level | 85dB - 95dB |
| Product Dimensions | Φ51mm x H55mm |
| Smart Home Platform | Tuya |
| Certification | CE |
| Origin | Mainland China |

Image: Diagram showing the dimensions of the smoke detector (51mm diameter, 55mm height).
6. Setup
6.1. Installation Location
Choose a suitable location for your smoke detector. It is recommended to install smoke detectors in every sleeping area, hallways leading to sleeping areas, and on every level of your home, including the basement. Avoid installing near kitchens, bathrooms, or garages where steam or fumes might cause false alarms.

Image: The smoke detector is suitable for various scenarios including homes, hotels, office buildings, factories, and warehouses.
6.2. Mounting the Detector
- Select a wall or ceiling location.
- Use the mounting bracket (if detachable) as a template to mark the screw positions.
- Drill two holes at the marked positions.
- Insert the wall plugs into the drilled holes.
- Secure the mounting bracket to the wall/ceiling using the provided screws.
- Attach the smoke detector to the mounting bracket by twisting it clockwise until it locks into place.
- Alternatively, for temporary or non-drilling installation, a strong adhesive pad can be used on a clean, flat surface.

Image: A detailed view of the smoke detector, showing its design and mounting points.
6.3. Battery Installation
If the CR2 battery is not pre-installed, open the battery compartment (usually by twisting the back cover) and insert the CR2 battery, observing the correct polarity (+/-). Close the compartment securely.
6.4. Pairing with Tuya Smart Life App
To integrate the smoke detector into your smart home system, you will need a Tuya-compatible Zigbee gateway (sold separately).
- Ensure your Zigbee gateway is powered on and connected to the Tuya Smart Life app.
- Open the Tuya Smart Life app on your smartphone.
- Tap the "+" icon to add a new device.
- Select "Sensor" or "Security & Video Surveillance" and then "Smoke Detector (Zigbee)".
- Follow the on-screen instructions to put the smoke detector into pairing mode. This usually involves pressing and holding the self-test button for a few seconds until an indicator light flashes.
- The app will search for the device. Once found, confirm the pairing.
- You can rename the device and assign it to a specific room for easier management.
7. Operating Instructions
7.1. Alarm Function
When smoke is detected, the device will emit a loud audible alarm (85-95dB) and its LED indicator will flash red. Simultaneously, if paired with your Tuya system, you will receive an instant notification on your smartphone via the Tuya Smart Life app.

Image: Mobile app remote monitoring showing an alarm status.
7.2. Mute Function
In case of a false alarm (e.g., from cooking fumes), you can temporarily mute the alarm through the Tuya Smart Life app. Look for the mute option on the device's control panel within the app. The alarm will typically silence for a short period and then reset.

Image: Demonstrates the low power reminder and the remote mute function via the app.
7.3. Self-Test
It is crucial to test your smoke detector regularly (e.g., monthly) to ensure it is functioning correctly.
- Press and hold the self-test button located on the device.
- The detector should emit a loud alarm sound and the LED light should flash.
- Release the button. If the alarm sounds, the device is working. If not, check the battery or refer to the troubleshooting section.
7.4. Low Power Reminder
When the battery level is low, the smoke detector will typically emit a short chirp periodically and/or send a low battery notification to your Tuya Smart Life app. Replace the battery promptly when this occurs.
8. Maintenance
8.1. Battery Replacement
When you receive a low power reminder, replace the CR2 battery immediately. To replace:
- Twist the detector counter-clockwise to remove it from its mounting bracket.
- Open the battery compartment.
- Remove the old CR2 battery and insert a new one, ensuring correct polarity.
- Close the battery compartment and reattach the detector to its mounting bracket by twisting clockwise.
- Perform a self-test to confirm proper operation.
8.2. Cleaning
Dust and debris can accumulate on the smoke detector and interfere with its performance. Clean your smoke detector at least once every six months:
- Gently vacuum the exterior of the detector, especially around the sensing chamber openings, using a soft brush attachment.
- Wipe the exterior with a clean, damp cloth. Do not use cleaning sprays or solvents.
9. Troubleshooting
| Problem | Possible Cause / Solution |
|---|---|
| Detector does not alarm during self-test. |
|
| Detector chirps periodically. |
|
| False alarms. |
|
| Cannot pair with Tuya app. |
|
| No app notifications. |
|
10. User Tips
- Regular Testing: Make it a habit to press the self-test button monthly to ensure your detector is always ready.
- Strategic Placement: Consider placing detectors not just in hallways, but also inside bedrooms for enhanced safety, especially if doors are often closed at night.
- Battery Check: Pay attention to the low battery chirps and replace the CR2 battery promptly to maintain continuous protection.
- Cleanliness: A quick vacuum around the detector every few months can prevent false alarms caused by dust accumulation.
11. Warranty and Support
For warranty information and technical support, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your proof of purchase for warranty claims.