1. Safety Brief
Congratulations on your purchase of the adjustable programmable DC power supply. To fully utilize this power supply, please keep this manual for reference carefully, especially on the safety contents, to avoid personal injury or damage on the power supply.
Safety Symbols
The following safety symbols will appear in this manual or on the DC power supply:
- ⚠ Attention: Indicates a potential hazard that could result in injury or damage to the product.
- ⚡ High Voltage: Indicates the presence of dangerous voltage.
- ⏚ Grounding: Indicates a grounding terminal.
WARNING:
- Make sure to input the correct AC voltage. The wrong AC voltage will damage the device.
- Do not operate this power supply in environments with flammable, explosive, or corrosive gas.
- Do not block the ventilation openings and ensure the power supply is operated in a well-ventilated environment.
- Since there is high voltage inside the device (even when powered off, high voltage may remain in the circuit for a certain period), do not attempt to repair or modify it yourself.
2. Product Introduction
The Jesverty SPS series is a programmable switch mode DC power supply with a digital display, showing voltage, current, and power simultaneously. It is widely applied in product aging, R&D research, education, manufacturing, and more. The outputs of voltage and current can be adjusted continuously. It features excellent stability, low ripple, and circuit protections such as short-circuit, over-voltage, over-current, and over-temperature. It also includes built-in USB-A and USB-C fast charging ports.
3. Setup
3.1 Initial Inspection
Upon receiving your new power supply, please perform the following checks:
- Check for any damages during transportation.
- Verify that all standard accessories are included in the package.
- Ensure the power supply is compliant with the actual input voltage before powering on.
- Confirm that the output voltage and current function normally after power on.
If any problems are found, please contact your local distributor for assistance.
3.2 Grounding
When operating the power supply, ensure the power cord is properly grounded. If your power socket lacks grounding, you can connect the housing case of the power supply to the ground wire. Proper grounding prevents power supply leakage and reduces output ripple interference.
3.3 Input Voltage Selection
The device supports switchable input voltages: AC115V/230V±5% 50/60Hz. Ensure the correct AC voltage is selected for your region to prevent damage to the device.
3.4 Connecting the Load
Follow these steps to connect your load:
- Rotate the terminal knob counterclockwise.
- Insert the load terminal.
- Turn the terminal knob clockwise to secure the connection.
- A banana plug can also be directly inserted into the terminal hole.
Attention:
- Improper connection may result in damage to the power supply and the connected load.
- When connecting a battery load, do not reverse the polarity of the "+" and "-" terminals, as this may damage the power supply.
- Select a suitable output wire based on the output current value and ensure a tight, clean, and rust-free connection to avoid damage to terminals, load devices, or fire.
4. Operating Instructions
4.1 Power On/Off
Press the green POWER button lightly to turn on the power supply. The display will show the voltage and current values that were set when the device was last powered off.
To turn off the output, press the OUT button. The output power display will show "OFF". Press it again to turn the output back on.
Video 1: Demonstration of basic power supply operation, including power on/off, voltage/current adjustment, OCP, USB charging, and reverse polarity protection.
4.2 Voltage Adjustment
Use the V-COARSE and V-FINE knobs to adjust the voltage:
- Press the V-COARSE or V-FINE knobs to select the digit you wish to adjust. The selected digit will blink.
- Rotate the V-COARSE knob to adjust the value of the first two digits (coarse adjustment).
- Rotate the V-FINE knob to adjust the value of the last two digits (fine adjustment).
- Rotate clockwise to increase the value and counterclockwise to decrease it.
- After setting, wait 3 seconds for the current display to stop blinking, and the setting will be stored.
4.3 Current Adjustment
Use the A-COARSE and A-FINE knobs to adjust the current:
- Press the A-COARSE or A-FINE knobs to select the digit you wish to adjust. The selected digit will blink.
- Rotate the A-COARSE knob to adjust the value of the first two digits (coarse adjustment).
- Rotate the A-FINE knob to adjust the value of the last two digits (fine adjustment).
- Rotate clockwise to increase the value and counterclockwise to decrease it.
- After setting, wait 3 seconds for the current display to stop blinking, and the setting will be stored.
4.4 Output On/Off Control
Press the green OUT button to activate or deactivate the power supply output. When the output is off, the display shows "OFF".
4.5 OCP (Over-Current Protection) Setting
The OCP function protects the load device from overcurrent. To enable and set OCP:
- Press the red OCP button to enter the OCP setting interface.
- Rotate the V-COARSE knob. When the display changes from "0" to "1", the OCP indicator light turns on, indicating OCP is enabled.
- Press the OCP button again to store and exit the OCP setting screen.
- When the power supply detects a short-circuit or the actual output current exceeds the set OCP trip point, the OCP will be activated. The power supply will turn off the output immediately, and the OCP indicator will blink to indicate an alarm.
- To resume output after an OCP alarm, fix the problem and press the OUT button.
4.6 OPN (Output Status Setting)
OPN is a function that allows the unit to output voltage and current immediately when the power switch is turned on without pressing the "Output" button.
- Press the "OUTPUT" button for 3 seconds to activate (or exit) OPN mode.
- A slight press of the "OUTPUT" button will toggle the display between 0 and 1.
- After setting, press the "OUTPUT" button for 3 seconds again, and the system returns to the original interface. The OPN mode is activated and its indicator is lit.
- To exit OPN mode, while in OPN mode interface, slightly press "OUTPUT" button to display 0, and the OPN indicator turns off. Then press "OUTPUT" button for 3 seconds to exit OPN mode.
4.7 USB Charging Function
The Jesverty SPS series includes dual charging ports (USB-A and USB-C) that support 20W fast charging. These ports can be used to charge mobile phones, Arduino UNO, Raspberry Pi, or other electronic modules.
4.8 Intelligent Battery Charging Function
The gray CHG button is used to enable the intelligent battery charging function. Press it lightly, and the "CHG" indicator light turns on, indicating charging is active. The "Ah" display represents ampere-hour, and the counting number is the energy charged into the battery.
4.9 Constant Voltage/Constant Current Characteristics
This series of power supplies features constant voltage/constant current automatic conversion. This means the power supply can automatically switch between constant voltage (CV) and constant current (CC) modes based on load changes. The intersection between these modes is called the conversion point.
- Constant Voltage (CV) Mode: If the load causes the power supply to operate in CV mode, a constant voltage is output. As the load increases, the output voltage remains constant, and the output current increases.
- Constant Current (CC) Mode: When the current value reaches the set current limit, the power supply will automatically switch to CC mode. The output current remains stable, and the output voltage decreases proportionally as the load increases further.
The CV indicator light is on during constant voltage mode, and the CC indicator is on during constant current mode.
4.10 Screen Brightness Adjustment
When the output is off, you can adjust the screen brightness by turning the central knob. This feature ensures readability even in dark environments.
5. Maintenance
5.1 Product Care
- Disconnect the power when the product is not in use.
- Unplug the power supply before cleaning.
- Do not use hydrocarbons, chlorides, similar solvents, or abrasive cleaners.
5.2 Fuse Replacement
If the fuse blows, the power supply will stop working. To replace the fuse:
- First, identify and correct the cause of the blown fuse.
- Turn off the power and unplug the power cord from the outlet.
- Open the fuse cabin (refer to the diagram below).
- Replace the blown fuse with a new one of the same specification.
- Close the fuse cabin.
HIGH VOLTAGE! DANGER! For effective safety protection, it is only necessary to replace the fuse of a specific specification. Before replacing the fuse, the power must be turned off and the power cord must be unplugged from the power outlet.
6. Troubleshooting
- "EER" Sign Appears: If the "EER" sign appears, it indicates that reverse connection protection is enabled. This typically happens when the output terminals are connected with reverse polarity. Correct the wiring to resolve this.
- "CHG" Indicator Light Flashes: If the cables are disconnected during battery charging, the "CHG" indicator light will flash, indicating that the charging function is abnormal. To reset, press the CHG button lightly to turn off the intelligent charging function, press CHG again to reset it, and then reconnect the power cord to continue charging. If the "CHG" indicator light flashes when the battery is connected, it indicates the battery is fully charged.
- Power On/Off "EER" Sign: If the power is turned off and then immediately turned back on within a few seconds, you might find the "EER" sign occurs. This is because the output terminal is still discharging the electricity stored from the last use.
- General Malfunction: If any other malfunction occurs, please consult with your local A/S for assistance, or return the defective unit for repair. Do not attempt to repair or modify the device yourself due to high internal voltages.
7. Specifications
7.1 General Specifications
| Attribute | Value |
|---|---|
| Brand Name | Jesverty |
| Model Number | SPS |
| Type | Power Supply |
| Use | Telecommunications |
| Output Type | SINGLE |
| Output Current | 0-10A |
| Output Power | 150-500W (includes 500W) |
| Rated Capacity | 40-1000VA (includes 40VA) |
| EU LVD Voltage | Below 50Vac or 75Vdc |
| is_customized | Yes |
| High-concerned chemical | None |
| Origin | Mainland China |
| Product Dimension | 200 x 90 x 160mm (L x W x H) |
| Product Weight | 1.13Kg |
7.2 Switchable DC Regulated Power Supply Models
| Model Number | Output Voltage | Output Current | Output Power | Fuse Standard |
|---|---|---|---|---|
| SPS-3005V | 0-30V | 0-5A | 150W | T4A/T6A |
| SPS-3010V | 0-30V | 0-10A | 300W | T5A/T8A |
| SPS-6005V | 0-60V | 0-5A | 300W | T5A/T8A |
| SPS-12003V | 0-120V | 0-3A | 360W | T5A/T8A |
7.3 Additional Specifications
- Input Voltage: AC115V/230V±5% 50/60Hz
- Operating Temperature: 0°C ~ 40°C
- Storage Temperature: -10°C ~ 70°C
- Relative Humidity (Operating): <80%RH
- Relative Humidity (Storage): <70%RH
- Voltage Stability: ≤0.5%+3mV
- Load Stability (Voltage): ≤0.5%+3mV
- Ripple Noise (Voltage): ≤0.5%V P-P
- Current Stability: ≤0.5%+3mA
- Load Stability (Current): ≤0.5%+3mA
- Ripple Noise (Current): ≤0.5%V P-P
- Protection Mode: Short-Circuit, Over-Current
- Display: Four-digit tube, 3-group display on voltage, current, power
- Display Accuracy: 0.5%+5digit
- Display Resolution: Voltage 0.01V, Current: 0.001A (>100V at 0.1V; >10A at 0.01A)
8. Warranty and Support
8.1 Product Warranty
This product is offered free maintenance service within one year from the date of purchase. The warranty does not cover:
- Failures caused by improper use, such as improper handling, repair, modification, or adjustment of the device.
- Consumable materials.
- Damage from natural disasters such as floods, fires, or earthquakes.
Maintenance costs are charged for repairs that exceed the warranty period, and the costs incurred for maintenance are the responsibility of the user.
8.2 Contact Information
For technical support or warranty claims, please contact:
Ningbo Kaijia Electronic Commerce Co., Ltd.Address: Room 609, No. 18 Rikui Road, Jishigang, Haishu District, Ningbo, China
Telephone: +86 18757492227
Email: vincent@jesverty.com
A PDF version of this user manual is available for download: User Manual (PDF).
9. User Tips
- Test Leads: The included test leads are suitable for general use. For long-term projects involving high currents, it is recommended to use test leads with sufficient current capacity.
- Calibration: The voltage and current are generally well-calibrated, but it's always good practice to verify with a multimeter for critical applications.
- Quiet Operation: Users have noted the device operates quietly, making it suitable for various work environments.
- Space-Saving Design: The compact size of the power supply helps save valuable workbench space.
- Intelligent Features: Take advantage of the precise adjustments, output on/off control, and intelligent battery charging function for enhanced usability.
10. Packing List
The product package typically includes:
- 1x Jesverty SPS Series Power Supply Unit
- 1x Power Cord
- 1x Output Load Cord (Test Leads)
- 1x User's Manual