1. Introduction
The CEM DT-38092 LED Light Meter is designed to measure light from various visible luminaries, including white light LED, fluorescent, metal halide, high-pressure sodium, and incandescent sources. This manual provides essential information for the safe and effective use of your device.

2. Safety Precautions
CAUTION
Be extremely careful for the following conditions while measuring.
- Do not operate the meter under environments with explosive gas (material), combustible gas (material) steam, or areas filled with dust.
- To ensure accurate readings, replace the battery immediately when the low battery symbol appears on the LCD.
- To prevent damage from contamination or static electricity, avoid touching the circuit board without adequate protective measures.
- This instrument is designed for indoor use in an environment of pollution degree 2.
- Operation Altitude: Up to 2000 M.
- Operating Temperature & Humidity: 5°C ~ 40°C, 0% ~ 70%RH.
- Storage Temperature & Humidity: -10°C ~ 60°C, 0% ~ 70%RH.
- EMC Compliance: EN61326-1(2006), IEC61000-4-2(2006), IEC61000-4-3(2006)+(2007).
3. Product Description
The CEM DT-38092 is a professional LED intensity/solar intensity tester. It offers high accuracy and a wide measuring range, making it suitable for various applications.

3.1. Features
- Overload Indication: LCD screen displays "OL" in the upper left-hand corner.
- Low Battery Indication: A battery symbol indicates low power.
- Sampling Rate: 2.5 times per second for digital display.
- Spectral Response: Close to CIE luminous spectral efficiency.
- Cosine Angular Corrected: Ensures accurate readings from various angles.
- Standards Compliance: According to JIS C1609:1993 and CNS 5119 general A class specifications.
- Measuring Light Sources: LED white light and all visible light.
- Measurement Units: Lux or Foot-candle.
- Wide Application: Suitable for warehouses, factories, offices, schools, hospitals, photography, parking garages, museums, art galleries, stadiums, and building security.
- Data Hold: Freezes the current reading on the display.
- MAX/AVG/MIN Hold: Records maximum, average, and minimum values.
- Zero Adjustment: For precise calibration.
- Auto Power Off: Automatically turns off after 3 to 5 minutes of inactivity (can be disabled).
- Auto Ranging: Automatically selects the appropriate measurement range.
3.2. Instrument Description

- Display (LCD): Shows measurement readings and indicators.
- LUX/FC/CD button: Selects measurement units (Lux, Foot-candle, or Candela for luminous intensity).
- MEM/READ: Memory store/read button.
- MAX/AVG/MIN and Setup Upward: Accesses Max/Avg/Min functions and navigates menus upward.
- Real-time Auto Zero: Performs real-time zero adjustment.
- Power ON/OFF and Disable Auto Power Off: Turns the device on/off and toggles auto power off.
- Setup Downward: Navigates menus downward.
- DATA HOLD and Light Source Select (L.S.): Holds data and selects light source type.
- Photo Detector: The sensor for light measurement.
4. Setup
4.1. Battery Replacement
WARNING
If the low battery symbol appears on the LCD, please replace the battery immediately.
The device uses a 9V battery (included). To replace the battery:
- Remove the battery cover.
- Replace the old battery with a new 9V battery.
- Install the battery cover securely.
Note: When the meter is not in use for a long time, please remove the batteries and store the device in a place of low temperature and humidity.
5. Operation
5.1. Basic Measurement
- Press the Power button to turn the unit on or off.
- Remove the sensor cap and position the sensor perpendicular to the light source.
- Select the desired unit (LUX or FC) using the LX/FC/CD button.
- After testing, replace the sensor cover to protect the filter and sensor.
5.2. Data Hold
Press the HOLD button to freeze the current reading on the LCD screen.
5.3. Zero Adjustment
Press the ZERO button for zero adjustment. If the light sensor cap is not attached, "CAP" will be shown on the screen. Ensure the cap is attached for accurate zeroing.
5.4. MAX/AVG/MIN Function
Press the MAX/AVG/MIN button simultaneously to lock up and display the maximum, average, and minimum values of the measured data. Press the button for more than 1 second to disable this feature.
5.5. Light Source Selection and Correction
The meter features light source selection from 1 to 9, each with adjustable correction parameters (default 1.000, range 0.001 to 1.999).
- Press the L.S. button for more than 1 second. The digits "1.000" on the lower right of the screen will flash.
- Use the Up or Down buttons to change the calibration parameters.
- Press the L.S. button for less than 1 second. The LCD Light Source indicator below "LN" will flash, allowing you to change from L1 to L9.
- Press HOLD for more than 1 second to complete the setup.
Light Source Factors:
- L1: LED white day light: 0.99
- L2~L9: Default standard light source A: 1.00
5.6. Auto Power Off
The meter automatically powers off after approximately 3 to 5 minutes of inactivity. To disable or re-enable this feature, press the Power button for more than 1 second while the unit is on. The auto-shutdown feature is enabled if a specific symbol (not specified in the text, but implied by the PDF) is shown on the screen.
5.7. Memory (MEM) Function
Press the MEM button for one second to store the current data. The LCD will display "M" and a record number (e.g., NO.01 to NO.99).
5.8. Read Memory (READ) Function
Press the READ button for more than one second to display stored values. The LCD will show "R", "MEM", and the record number. Use the Up or Down buttons to review records. Press the READ button for more than one second again to disable this feature.
5.9. Clear Memory (CLEAR) Function
When the power is off, press the MEM and READ buttons together. The screen will display "Clr", indicating that all memorized data has been erased.
6. Luminous Intensity Measurement
To measure luminous intensity (cd):
- Press the Power button to turn the unit on or off.
- Remove the sensor cap and place the sensor perpendicular to the light.
- Press the LX/FC/CD button for more than one second to select Candela (cd) unit.
- Press the Up or Down button to select feet (ft) or meters (m) for distance.
- Press the LX/FC/CD button for less than one second.
- Press the Up or Down button to set the distance between the light source and the measurement base level.
- Press the LX/FC/CD button for less than one second.
- Read the luminous intensity from the display.
- Press the LX/FC/CD button for more than one second to disable the feature.
The luminous intensity is calculated using the formula: Luminous intensity (cd) = illumination (LUX) × distance (m²)
The preset maximum distance is 0.01 ~ 30.47 m or 0.01 ~ 99.99 ft.
If a single light source is used and is regarded as a single-point light source, the luminous intensity of the light source can be calculated and displayed by setting the distance from the light source to the measuring point.

7. Specifications
| Parameter | Value |
|---|---|
| Display | 4000 count, maximum display 3999 |
| Sensor | Silicon photodiode with filter |
| Measuring Range | 40, 400, 4000, 40000, 400000 Lux 40, 400, 4000, 40000 Footcandles |
| Accuracy | ±3% (Calibrated to standard incandescent lamp 2856°K and corrected LED day white-light spectrum) ±6% (other visible light source) |
| Angle deviation from cosine characteristics | 30°: ±2% 60°: ±6% 80°: ±25% |
| Power Supply | 1.5V AAA*3 alkaline battery (Note: PDF says 9V battery in accessories, but 1.5V AAA*3 in specs. Following PDF specs table for consistency.) |
| Dimensions (HxWxD) | 160mm x 58mm x 27mm (from JSON) 162(L)x63(W)x28(H) (from PDF) |
| Weight | 280g (from JSON) about 250g (from PDF) |
| Accessories | 9V battery, Gift box, User manual |
| Length of wire for light sensor | Approx. 1.5M |
8. Recommended Levels of Illumination
The following table provides suitable levels of illuminance according to JIS standard Z 9110-1979:
Offices
| Illuminance (lux) | Place |
|---|---|
| 1500 to 750 | Offices, designing, drawing rooms |
| 750 to 300 | Offices, conference rooms, computer rooms |
| 300 to 100 | Workrooms, corridors, stairways, restrooms |
| 75 to 30 | Indoor emergency stairways |
Factories
| Illuminance (lux) | Place |
|---|---|
| 3000 to 1500 | Where such work as assembling, inspecting testing, selecting, extremely precision Visual work |
| 1500 to 750 | Assembling, inspecting, testing, selecting, precision visual work |
| 750 to 300 | Assembling, inspecting, testing, selecting and visual ordinary work |
| 300 to 150 | Wrapping and packing |
| 75 to 30 | Indoor emergency stairways |
Schools
| Illuminance (lux) | Place |
|---|---|
| 1500 to 300 | Precision drawing or drafting, precision experimenting, library |
| 750 to 200 | Classrooms, library reading rooms, Staff room, gymnasia |
| 300 to 75 | Lecture halls, assembly room corridors, locker rooms, stairways, restrooms |
| 75 to 30 | Warehouses and emergency stairways |
| 10 to 2 | School passages |
9. Attention and Care
- When testing, ensure the light source is located at the right top end (0 degree) of the light sensor ball plane for accurate readings.
- When the meter is not in use, always keep the cap on the light sensor to protect the photo diode from wearing out.

10. User Tips
Based on available information, no specific user tips or common issues were highlighted in reviews or Q&A for this product.
11. End of Life and Disposal
This symbol indicates that equipment and its accessories shall be subject to separate collection and correct disposal, in accordance with local regulations for electronic waste.

12. Additional Resources
For a detailed PDF version of the user manual, please refer to the official document: CEM DT-38092 User Manual (PDF).