CEM DT-38092

Contents

CEM DT-38092 LED Light Meter User Manual

Model: DT-38092

1. Introduction

The CEM DT-38092 LED Light Meter is designed to measure light from various visible luminaries, including white light LED, fluorescent, metal halide, high-pressure sodium, and incandescent sources. This manual provides essential information for the safe and effective use of your device.

CEM DT-38092 LED Light Meter with its detachable light sensor and protective cap.
Figure 1: CEM DT-38092 LED Light Meter and Light Sensor.

2. Safety Precautions

CAUTION

Be extremely careful for the following conditions while measuring.

  • Do not operate the meter under environments with explosive gas (material), combustible gas (material) steam, or areas filled with dust.
  • To ensure accurate readings, replace the battery immediately when the low battery symbol appears on the LCD.
  • To prevent damage from contamination or static electricity, avoid touching the circuit board without adequate protective measures.
  • This instrument is designed for indoor use in an environment of pollution degree 2.
  • Operation Altitude: Up to 2000 M.
  • Operating Temperature & Humidity: 5°C ~ 40°C, 0% ~ 70%RH.
  • Storage Temperature & Humidity: -10°C ~ 60°C, 0% ~ 70%RH.
  • EMC Compliance: EN61326-1(2006), IEC61000-4-2(2006), IEC61000-4-3(2006)+(2007).

3. Product Description

The CEM DT-38092 is a professional LED intensity/solar intensity tester. It offers high accuracy and a wide measuring range, making it suitable for various applications.

CEM DT-38092 LED Light Meter highlighting its features: test value up to 400,000 Lux/Fc, resolution 0.1 Lux/Fc, maximum and minimum readings, and data retention function.
Figure 2: Key features of the DT-38092 LED Light Meter.

3.1. Features

  • Overload Indication: LCD screen displays "OL" in the upper left-hand corner.
  • Low Battery Indication: A battery symbol indicates low power.
  • Sampling Rate: 2.5 times per second for digital display.
  • Spectral Response: Close to CIE luminous spectral efficiency.
  • Cosine Angular Corrected: Ensures accurate readings from various angles.
  • Standards Compliance: According to JIS C1609:1993 and CNS 5119 general A class specifications.
  • Measuring Light Sources: LED white light and all visible light.
  • Measurement Units: Lux or Foot-candle.
  • Wide Application: Suitable for warehouses, factories, offices, schools, hospitals, photography, parking garages, museums, art galleries, stadiums, and building security.
  • Data Hold: Freezes the current reading on the display.
  • MAX/AVG/MIN Hold: Records maximum, average, and minimum values.
  • Zero Adjustment: For precise calibration.
  • Auto Power Off: Automatically turns off after 3 to 5 minutes of inactivity (can be disabled).
  • Auto Ranging: Automatically selects the appropriate measurement range.

3.2. Instrument Description

Diagram of the CEM DT-38092 LED Light Meter with numbered parts: 1-LCD, 2-LUX/FC/CD button, 3-MEM/READ, 4-MAX/AVG/MIN and setup upward, 5-Real time auto zero, 6-Power ON/OFF and disable auto power off, 7-Setup downward, 8-DATA HOLD and light source select (L.S.), 9-Photo detector.
Figure 3: CEM DT-38092 Instrument Layout.
  1. Display (LCD): Shows measurement readings and indicators.
  2. LUX/FC/CD button: Selects measurement units (Lux, Foot-candle, or Candela for luminous intensity).
  3. MEM/READ: Memory store/read button.
  4. MAX/AVG/MIN and Setup Upward: Accesses Max/Avg/Min functions and navigates menus upward.
  5. Real-time Auto Zero: Performs real-time zero adjustment.
  6. Power ON/OFF and Disable Auto Power Off: Turns the device on/off and toggles auto power off.
  7. Setup Downward: Navigates menus downward.
  8. DATA HOLD and Light Source Select (L.S.): Holds data and selects light source type.
  9. Photo Detector: The sensor for light measurement.

4. Setup

4.1. Battery Replacement

WARNING

If the low battery symbol appears on the LCD, please replace the battery immediately.

The device uses a 9V battery (included). To replace the battery:

  1. Remove the battery cover.
  2. Replace the old battery with a new 9V battery.
  3. Install the battery cover securely.

Note: When the meter is not in use for a long time, please remove the batteries and store the device in a place of low temperature and humidity.

5. Operation

5.1. Basic Measurement

  1. Press the Power button to turn the unit on or off.
  2. Remove the sensor cap and position the sensor perpendicular to the light source.
  3. Select the desired unit (LUX or FC) using the LX/FC/CD button.
  4. After testing, replace the sensor cover to protect the filter and sensor.

5.2. Data Hold

Press the HOLD button to freeze the current reading on the LCD screen.

5.3. Zero Adjustment

Press the ZERO button for zero adjustment. If the light sensor cap is not attached, "CAP" will be shown on the screen. Ensure the cap is attached for accurate zeroing.

5.4. MAX/AVG/MIN Function

Press the MAX/AVG/MIN button simultaneously to lock up and display the maximum, average, and minimum values of the measured data. Press the button for more than 1 second to disable this feature.

5.5. Light Source Selection and Correction

The meter features light source selection from 1 to 9, each with adjustable correction parameters (default 1.000, range 0.001 to 1.999).

  1. Press the L.S. button for more than 1 second. The digits "1.000" on the lower right of the screen will flash.
  2. Use the Up or Down buttons to change the calibration parameters.
  3. Press the L.S. button for less than 1 second. The LCD Light Source indicator below "LN" will flash, allowing you to change from L1 to L9.
  4. Press HOLD for more than 1 second to complete the setup.

Light Source Factors:

  • L1: LED white day light: 0.99
  • L2~L9: Default standard light source A: 1.00

5.6. Auto Power Off

The meter automatically powers off after approximately 3 to 5 minutes of inactivity. To disable or re-enable this feature, press the Power button for more than 1 second while the unit is on. The auto-shutdown feature is enabled if a specific symbol (not specified in the text, but implied by the PDF) is shown on the screen.

5.7. Memory (MEM) Function

Press the MEM button for one second to store the current data. The LCD will display "M" and a record number (e.g., NO.01 to NO.99).

5.8. Read Memory (READ) Function

Press the READ button for more than one second to display stored values. The LCD will show "R", "MEM", and the record number. Use the Up or Down buttons to review records. Press the READ button for more than one second again to disable this feature.

5.9. Clear Memory (CLEAR) Function

When the power is off, press the MEM and READ buttons together. The screen will display "Clr", indicating that all memorized data has been erased.

6. Luminous Intensity Measurement

To measure luminous intensity (cd):

  1. Press the Power button to turn the unit on or off.
  2. Remove the sensor cap and place the sensor perpendicular to the light.
  3. Press the LX/FC/CD button for more than one second to select Candela (cd) unit.
  4. Press the Up or Down button to select feet (ft) or meters (m) for distance.
  5. Press the LX/FC/CD button for less than one second.
  6. Press the Up or Down button to set the distance between the light source and the measurement base level.
  7. Press the LX/FC/CD button for less than one second.
  8. Read the luminous intensity from the display.
  9. Press the LX/FC/CD button for more than one second to disable the feature.

The luminous intensity is calculated using the formula:
Luminous intensity (cd) = illumination (LUX) × distance (m²)

The preset maximum distance is 0.01 ~ 30.47 m or 0.01 ~ 99.99 ft.

If a single light source is used and is regarded as a single-point light source, the luminous intensity of the light source can be calculated and displayed by setting the distance from the light source to the measuring point.

CEM DT-38092 LED Light Meter measuring light from an LED bulb, showing a reading of 2675 Lux.
Figure 4: Measuring light intensity with the DT-38092.

7. Specifications

ParameterValue
Display4000 count, maximum display 3999
SensorSilicon photodiode with filter
Measuring Range40, 400, 4000, 40000, 400000 Lux
40, 400, 4000, 40000 Footcandles
Accuracy±3% (Calibrated to standard incandescent lamp 2856°K and corrected LED day white-light spectrum)
±6% (other visible light source)
Angle deviation from cosine characteristics30°: ±2%
60°: ±6%
80°: ±25%
Power Supply1.5V AAA*3 alkaline battery (Note: PDF says 9V battery in accessories, but 1.5V AAA*3 in specs. Following PDF specs table for consistency.)
Dimensions (HxWxD)160mm x 58mm x 27mm (from JSON)
162(L)x63(W)x28(H) (from PDF)
Weight280g (from JSON)
about 250g (from PDF)
Accessories9V battery, Gift box, User manual
Length of wire for light sensorApprox. 1.5M

9. Attention and Care

  • When testing, ensure the light source is located at the right top end (0 degree) of the light sensor ball plane for accurate readings.
  • When the meter is not in use, always keep the cap on the light sensor to protect the photo diode from wearing out.
Diagram showing the correct placement of the light sensor relative to the light source at 0 degrees for accurate measurement.
Figure 5: Correct light sensor placement for measurement.

10. User Tips

Based on available information, no specific user tips or common issues were highlighted in reviews or Q&A for this product.

11. End of Life and Disposal

This symbol indicates that equipment and its accessories shall be subject to separate collection and correct disposal, in accordance with local regulations for electronic waste.

Waste Electrical and Electronic Equipment (WEEE) symbol indicating separate collection.

12. Additional Resources

For a detailed PDF version of the user manual, please refer to the official document: CEM DT-38092 User Manual (PDF).

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.