1. Introduction

The ElecDemo YK-FC100K is a versatile digital display module designed for precise measurement of frequency, rotational speed, and counting. It is compatible with a wide range of proximity switch sensors (NPN/PNP, 3-wire/4-wire) and features Modbus RTU communication capabilities. This module is suitable for various applications including signal frequency measurement, motor speed monitoring, and workpiece counting in industrial and hobbyist settings.

ElecDemo YK-FC100K module with a sensor
Figure 1: ElecDemo YK-FC100K Multi-Function Measurement Module with a typical sensor.

2. Safety Information

  • Ensure the power supply voltage is within the specified range (5V-28V) to prevent damage to the module.
  • Always disconnect power before making any wiring changes.
  • Avoid exposing the module to moisture, extreme temperatures, or corrosive environments.
  • Handle with care to prevent electrostatic discharge (ESD) damage.
  • This module is intended for use by individuals familiar with electronic circuits and safety practices.

3. Specifications

Parameter Name Value Remark
Module ModelYK-FC100K
Module FunctionFrequency, rotational speed, counting measurement
Supply Voltage5-28V
Static Power Consumption20mA (TYP)
Compatible Sensors3-wire/4-wire NPN/PNP typeActive square wave pulse PWM is acceptable
Measure Level (High)18-30V
Measure Level (Low)0-15V
Measuring Range (Frequency)0-99999 Hz
Measuring Range (Rotational Speed)0-99999 RPM
Measuring Range (Counting)0-99999Default counting mode
Resolution (Frequency)0.001 Hz
Resolution (Rotational Speed)0.01 RPM
Resolution (Counting)1
Display MethodDigital tubes
Display Digits5 bits
Communication ProtocolsModbus RTUSupports 0x03, 0x06 function codes
Communication LevelRS485
Baud Rate2400, 4800, 9600 (default), 19200, 38400, 57600, 115200Data bit 8, stop bit 1, no check digit
Module ProtectionReverse power supply protection
Module ApplicationSignal frequency measurement, motor speed measurement, workpiece counting, etc.
Module Weight25g
Module Size60 x 29 x 30mm (Length x Width x Height)For your reference

4. Setup and Installation

4.1 Module Dimensions

The module has a compact design for easy integration. The opening size for panel mounting is 58x26mm.

Module dimension drawing showing 60mm length, 29mm width, 30mm height
Figure 2: Module Dimension Drawing. Overall dimensions are 60mm (Length) x 29mm (Width) x 30mm (Height). The required panel opening size is 58mm x 26mm.

4.2 Module Interface Diagram

The module features dedicated interfaces for power supply, communication, and sensor input. It also provides a 12V output for powering compatible sensors.

Module interface diagram showing power, communication, and sensor connections
Figure 3: Module Interface Diagram. Connections include 5-28V power supply, GND, 485B, 485A for communication, 12V output, Signal input, and GND for sensors. A reset button is also indicated.

4.3 Sensor Wiring

The YK-FC100K module is compatible with various NPN and PNP sensors. Ensure correct wiring to prevent damage and ensure accurate readings. It is recommended to connect the sensor before supplying power to the module.

Schematic diagram for NPN and PNP sensor wiring
Figure 4: Schematic Diagram of Sensor Wiring. This diagram illustrates connections for NPN and PNP 3-wire and 4-wire sensors, as well as active signal wiring. Brown wire connects to Power (+12V), Blue to Ground (GND), and Black to Signal Input (DI).

Example NPN 3-wire sensor connection: Connect the black wire to DI, the brown wire to the 12V output, and the blue wire to G (GND). Set the jumper cap to the left end, and configure P02 to 0 (falling edge trigger).

The module provides a 12V output for powering sensors, eliminating the need for a separate sensor power supply.

5. Operating Instructions

5.1 Key Operation and Menu Navigation

The module is operated using a single button for setting parameters and clearing data. The display will show the current measurement mode for 3 seconds after power-on, then switch to displaying measurement data.

Key operation diagram for menu navigation and settings
Figure 5: Key Operation Flowchart. This diagram details how to enter the settings menu, navigate parameters, adjust values, and save settings using short and long presses of the button.
  • Short Press: Clears measurement data (in measurement mode). In settings, it switches between parameters or adjusts values.
  • Long Press (3 seconds): Enters/exits the settings menu. In settings, it adjusts the cursor position.
  • Power-on with button held: Resets to factory settings.
  • If no operation for 10 seconds in the settings menu, it will automatically return to measurement mode.

5.2 Parameter Settings (P-01 to P-06)

To enter the settings menu, long-press the button for 3 seconds. Use short presses to navigate through the parameters (P-01 to P-06) and long presses to adjust the cursor or confirm changes.

Parameter Description Options/Range
P-01Measurement Mode Setting0: Frequency Mode, 1: Rotational Speed Mode, 2: Counting Mode (Range: 0-2)
P-02Trigger Mode Setting0: Falling Edge Trigger, 1: Rising Edge Trigger (Range: 0-1)
P-03Frequency Division Value Setting0.01-600.00 (Displayed measurement data = Measured value / Frequency division value)
P-04Filtering Setting0: Filter Off, 1: Filter On (Range: 0-1)
P-05Baud Rate Setting0: 2400, 1: 4800, 2: 9600, 3: 19200, 4: 38400, 5: 57600, 6: 115200 (Range: 0-6)
P-06Device Address Setting1-127 (Range: 1-127)

5.3 Understanding Frequency Division Value (P-03)

The frequency division value is primarily used when measuring rotational speed. If an external sensor generates 'N' pulse signals per revolution of a turntable or gear, setting the frequency division value to 'N' will ensure the module displays the correct RPM.

This parameter can also be used in other modes to adjust the data ratio. For example:

  • If the actual pulse frequency is 100Hz and the frequency division value is set to 1.6, the module will display 62.5 (100 / 1.6).
  • If the actual cumulative number of pulses is 50 (in counting mode) and the frequency division value is set to 0.4, the module will display 125 (50 / 0.4).

6. Maintenance

  • Keep the module clean and free from dust. Use a soft, dry cloth for cleaning.
  • Store the module in a dry environment, away from direct sunlight and extreme temperatures.
  • Regularly check wiring connections for security and integrity.

7. Troubleshooting

Problem Possible Cause Solution
Module does not power on. Incorrect power supply voltage or wiring. Verify power supply is within 5-28V and connections are correct (positive to V+, negative to GND).
Display shows "00000" or incorrect readings. Sensor not connected, faulty sensor, incorrect sensor wiring, or incorrect measurement mode (P-01) setting. Check sensor connection and functionality. Review sensor wiring diagrams (Figure 4). Ensure P-01 is set to the desired measurement mode.
Difficulty programming or navigating menus. Unfamiliarity with key operation sequence. Refer to the "Key Operation Flowchart" (Figure 5) and "Parameter Settings" section for detailed instructions on short and long presses.
Some digits on the display are faulty or not lighting up. Hardware defect. This may indicate a manufacturing defect. Contact the seller for support or replacement.
Communication via RS485 not working. Incorrect baud rate (P-05) or device address (P-06) settings, or wiring issues. Verify RS485 A/B wiring. Check P-05 and P-06 settings match your communication setup.

8. User Tips

  • Careful Wiring: Double-check all wiring connections, especially for sensors and power, before applying power to avoid damage.
  • Review Instructions: Take your time to understand the key operation and parameter settings. The provided diagrams are crucial for correct setup.
  • Sensor Compatibility: The module is designed to work with a wide range of NPN/PNP proximity sensors. Ensure your sensor type matches the module's capabilities.
  • PDF Manual: For additional detailed information, refer to the official user manual PDF available at: ElecDemo YK-FC100K User Manual (PDF).

9. Warranty and Support

For specific warranty information and technical support, please contact the seller or refer to the product listing where you purchased this module. Keep your purchase receipt as proof of purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.