1. Introduction
The HoldPeak HP-5800G Ammonia Gas Detector is a continuous quantitative analysis apparatus designed to monitor ammonia (NH3) concentration, temperature, and humidity. It utilizes a high-precision electrochemical principle sensor, offering fast response speed, high precision, stability, and good repeatability. This instrument is widely used in various fields including metallurgy, power plants, farms, mines, chemical industries, scientific research, medical, pharmaceutical, and environmental protection.
This device is an intellectual precise measurement apparatus. Please read through these instructions carefully before using it to ensure proper operation and safety.

2. Safety Information and Precautions
- This meter is a precise measurement apparatus. To avoid damaging the meter, keep it away from water and hot objects (more than 50°C).
- When the battery level shows low, please charge the lithium battery in time and continue to use the product after it is fully charged.
- The meter is automatically powered off if no button is pressed for 20 minutes.
- When the buzzer alarms, if the measured value is less than the alarming-line you have set up, please take measures to protect people, lives, and property.
- If you are not going to use this meter for a long period of time, turn off the meter to avoid damage due to battery oozing liquid.
- If you take out the batteries when the meter is on, the data preset for the grade 4 and grade 2 alarming-line will be lost. When the meter is powered on and enabled, the previous values preset for the grade 4 and grade 2 alarming will return.
- If you are going to save the values preset for the two grades of alarming lines, you must turn off the meter normally once.
- Old batteries must be handled according to local laws and regulations.
- We reserve the right to update and modify the specifications and specifications of our products without notice.

3. Package Contents
The HP-5800G Ammonia Gas Detector package typically includes the following items:
- HP-5800G Ammonia Gas Detector unit
- USB Cable for charging
- User Manual (this document)
- Packaging box
- Packaging bag/carrying case

4. Product Overview and Components
Familiarize yourself with the main components and display elements of your HP-5800G detector:

4.1. Display Explanation (Figure 1)
- Ammonia concentration display area
- Ammonia gas unit (ppm)
- Ammonia gas formula (NH3)
- AL1 indicate (First alarm setting)
- Temperature Unit (°C/°F)
- Temperature Measured value
- AL2 indicate (Second alarm setting)
- Battery indicator
- Humidity measured value
- Humidity Unit (%RH)
4.2. Button Functions (Figure 2)
- Power on/off button
- Increment button
- °C/°F Temperature unit conversion button
- Decrement button
- MODE button
- Alarm indicator light
- Charging indicator light
- Alarm setting button
- Display screen
- Sensor
- Charging interface
5. Setup and Initial Use
5.1. Charging the Device
Before first use, or when the battery indicator shows low, charge the device using the provided USB cable. The charging interface is located on the side of the device.
- When fully charged, the red light is on.
- When charging, the green light is on.

5.2. Sensor Preparation
During testing, ensure the protective cover of the probe sensor is opened to allow for accurate readings.
5.3. Tripod Mounting
The device features a screw hole for tripod mounting, allowing for continuous and hands-free measurement.

6. Operating Instructions
6.1. Power On/Off
Press the Power On/Off button (labeled with a power symbol) to turn the device on. Press it again to turn it off.
6.2. Temperature Unit Conversion (°C/°F)
The default temperature unit is Celsius (°C). Press the °C/°F Temperature button once to convert the display to Fahrenheit (°F).
6.3. Alarm Setting (AL1 and AL2)
The device features two alarm levels: AL1 (first alarm) and AL2 (second alarm).
- Press the Alarm Setting button to enter the setting state for AL1.
- Press the Alarm Setting button again to enter the setting state for AL2.
- While in the alarm setting state, use the Increment button (short press +0.1, long press +1) or Decrement button (short press -0.1, long press -1) to adjust the alarm value.
6.4. Auto Power Off (APO) Function
Press the MODE button to enter the interface for selecting the auto power off function.
- "APO ON" indicates the auto power off function is enabled.
- "APO OFF" indicates the auto power off function is disabled.
6.5. Reading the Display
The large screen liquid crystal display simultaneously shows the ammonia concentration, temperature, and humidity of the current environment. The colorful backlight ensures clear visibility even in dark conditions.
6.6. Alarm Indications
- When the AL1 (first-level alarm) setting value is reached, the alarm indicator light will flicker slowly, and the buzzer will ring slowly.
- When the AL2 (second-level alarm) setting value is reached, the alarm indicator light will flash rapidly, and the buzzer will ring rapidly.

6.7. Ammonia Hazard Index
Understanding the hazard levels of ammonia gas is crucial for safety:
| Concentration of Ammonia in Atmosphere | Human Physiological Reaction |
|---|---|
| 5~10 ppm | The nose may be aware of the smell. |
| 20 ppm | Aware of the special smell of ammonia. |
| 40 ppm | A few people feel mild stimulation of eye. |
| 100 ppm | A few minutes of exposure caused by ocular and nasal quite stimulating. |
| 400 ppm | Cause throat, nasal cavity and upper respiratory tract acute stimulation. |
| 700 ppm | Exposure for more than thirty minutes may cause permanent damage to the eye. |
| 1700 ppm | Severe cough, wheeze thirty minutes can be fatal. |
| 5000 ppm | Severe pulmonary edema disease, a moment can be fatal asphyxia. |
* The above parameters are for reference only.
7. Applications
The HP-5800G Ammonia Gas Detector is suitable for monitoring ammonia levels, temperature, and humidity in a variety of environments:
- Poultry Farms and Hen Houses
- Pig Farms, Horse Stables, Livestock, Cattle
- Landfills and Trash Management
- Animal Welfare Shelters and Fish Farms
- Renovation Works
- Office and Home environments
- Industrial settings

8. Technical Specifications
| Parameter | Specification |
|---|---|
| Detection of gas | Ammonia (NH3) |
| Measuring range | 0-100 ppm |
| Resolution | 0.1 ppm |
| Basic error | Less than ± 5% (F.S) |
| Response time | Less than 60 seconds |
| Recovery time | Less than 60 seconds |
| Repeatability | Less than ± 1% |
| Principle of sensor | Electrochemical principle, life for two years |
| Battery | Lithium battery (rechargeable), 1600 mAh capacity |
| Display | Large screen liquid crystal display (Segment LCD) |
| Alarm | Acoustic, optical double alarm, settable alarm value, 80 dB sound |
| Working temperature | -20 ~ 50 °C |
| Working humidity | 0-95% RH (Non Gel) |
| Is Smart Device | No |
| DIY Supplies | Woodworking |
| Certification | CE |

9. Maintenance
- Charging: Always charge the device when the battery indicator shows low to ensure optimal performance and longevity of the lithium battery.
- Storage: For long-term storage, ensure the device is powered off to prevent battery leakage and potential damage. Store in a cool, dry place away from extreme temperatures.
- Sensor Care: Keep the sensor clean and free from obstructions. Always open the protective cover during measurements.
10. Troubleshooting
- Inaccurate Readings: Ensure the sensor's protective cover is open during measurement. Keep the device away from water and hot objects.
- Device Not Powering On: Check battery level and charge if necessary. Ensure the power button is pressed correctly.
- Alarm Issues: Verify that alarm values (AL1, AL2) are set appropriately. If the buzzer is not sounding, check for any physical obstructions or damage.
- Data Loss: If the batteries are removed while the device is on, alarm settings may be lost. Always power off the device normally to save settings.
11. User Tips
- For continuous monitoring in a fixed location, utilize the tripod mounting hole to stabilize the device.
- Regularly check the battery level and charge promptly to ensure uninterrupted operation.
- When storing the device for extended periods, ensure it is powered off to prevent battery drainage and potential damage.
- Always open the sensor's protective cover during measurements for accurate readings.
12. Warranty and Support
The product comes with a 1-year warranty from the store. For any problems or concerns, please contact us via email for prompt response.
Email: AFTERSALES1010@HOTMAIL.COM
To ensure immediate solution and quick processing of your requests, please include the following information in your email:
- Order Number
- Platform of Your Purchase
- Full Model Number (HP-5800G)
- Description of the Problem (Attaching videos or photos can help us troubleshoot the problems even faster)
A user manual in PDF format is also available for download: User Manual (PDF)