1. Introduction
1.1 Purpose and Scope
This manual provides comprehensive instructions for the assembly, installation, operation, and troubleshooting of the Y&H 3.6KW Hybrid Solar Inverter. It also includes essential safety guidelines and information on tools and wiring. Please read this manual carefully before installation and operation, and keep it for future reference.
1.2 Product Overview
The Y&H 3.6KW Hybrid Solar Inverter is a multi-function inverter/charger that combines the capabilities of an inverter, solar charger, and battery charger. It is designed to provide uninterruptible power support in a compact size. The inverter features a comprehensive LCD display for user-configurable settings such as battery charging current, AC/solar charger priority, and acceptable input voltage ranges, making it adaptable to various applications.
This inverter can power a wide range of home and office appliances, including motor-type loads like tube lights, fans, refrigerators, and air conditioners.

Figure 1: Y&H 3.6KW Hybrid Solar Inverter Front View with Key Specifications (3.6KW 24V, AC 110V, DC 24V, 60-500Vdc PV input, MPPT 120A).

Figure 2: Summary of 3600W Hybrid Solar Inverter Features.
1.3 Key Features
- Pure sine wave output.
- Configurable input voltage range for home appliances and personal computers via LCD settings.
- Adjustable battery charging current based on application via LCD settings.
- Configurable AC/Solar Charger priority via LCD settings.
- Compatible with mains voltage or generator power.
- Automatic restart when AC power recovers.
- Comprehensive protection against overload, over temperature, and short circuit.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Seamless multi-battery connectivity (AGM, GEL, FLD, LI, SLD).

Figure 3: Seamless Multi-Battery Connectivity, showing compatibility with various battery types.

Figure 4: Comprehensive 360° Protection features including Short Circuit, Over-Load, Over Charge, Over Current, Backfill, Over Voltage, Under Voltage, and Over-Temperature protection.
1.4 Basic System Architecture
The inverter/charger can be integrated into a system with a generator or utility power source and PV modules. The full PDF manual (page 4) illustrates a typical application setup, showing the connections between solar power, inverter, battery, utility/generator, and home appliances.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with a battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow the required specifications to select the appropriate cable size. It is very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
- Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Refer to the INSTALLATION section of this manual for details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.
3. Setup (Installation)
3.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure that nothing inside the package is damaged. The package should contain:
- The inverter unit x 1
- User manual x 1
3.2 Preparation
Before connecting any wirings, remove the bottom cover by unscrewing the two screws as shown in the diagram in the full PDF manual (page 6).
3.3 Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install the inverter at eye level for easy reading of the LCD display.
- Allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit for proper air circulation and heat dissipation.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertical wall adherence.
- Ensure sufficient space for wire removal and heat dissipation.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two M6 screws. Refer to the full PDF manual (page 6) for detailed mounting diagrams.
3.4 Battery Connection
CAUTION: For safety and regulatory compliance, it is recommended to install a separate DC over-current protector or disconnect device between the battery and the inverter. Even if not required in some applications, over-current protection should always be installed.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It is crucial for system safety and efficient operation to use appropriate cables for battery connection. To reduce the risk of injury, use the recommended cable as specified below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/6.2KW | 1 x 2AWG | 25 | 2 Nm |
Follow these steps for battery connection:
- Remove 18 mm of insulation sleeve from positive and negative conductors.
- It is recommended to use bootlace ferrules on the ends of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram in the full PDF manual (page 7).
- Insert the battery wires flatly into the inverter's battery connectors and ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify correct polarity at both the battery and the inverter/charger, and ensure conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

Figure 5: Bottom view of the inverter showing battery connection terminals.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure that positive (+) is connected to positive (+) and negative (-) is connected to negative (-).
3.5 AC Input/Output Connection
CAUTION!! Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. The recommended AC breaker specifications are 32A for 3.6KW models and 50A for 6.2KW models.
CAUTION!! There are two terminal blocks marked "IN" and "OUT". Do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! For system safety and efficient operation, use appropriate cable sizes for AC input connection. To reduce the risk of injury, use the recommended cable sizes below.
| Model | Gauge | Cable (mm²) | Torque Value |
|---|---|---|---|
| 3.6KW | 12 AWG | 4 | 1.2 Nm |
| 6.2KW | 10 AWG | 6 | 1.2 Nm |
Follow these steps for AC input/output connection:
- Before making AC input/output connections, ensure the DC protector or disconnector is open.
- Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
- Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. (L → LINE (brown or black), N → Neutral (blue)).
WARNING: Ensure that the AC power source is disconnected before attempting to hardwire it to the unit.
- Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws. (L → LINE (brown or black), N → Neutral (blue)).
- Make sure all wires are securely connected.

Figure 6: Rear view of the inverter showing AC IN, MAIN OUT, SECOND OUT, PV IN, BATTERY, BMS, WiFi, RS232 ports.
CAUTION: Appliances such as air conditioners require 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation. Otherwise, the inverter/charger may trigger an overload fault and cut off output, but internal damage to the appliance may still occur.

Figure 7: Dual Load Output Power diagram, illustrating main and second output connections. The main output port will stop working if battery voltage falls below the set range (20V-23V), while the second output port can continue to operate.
3.6 PV Connection
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING! For system safety and efficient operation, use appropriate cables for PV module connection. To reduce the risk of injury, use the recommended cable sizes below.
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.6KW/6.2KW | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting PV modules, consider the following parameters:
- The Open Circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter (500Vdc).
- The Open Circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
| INVERTER MODEL | 3.6KW | 6.2KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
For detailed PV module configurations (e.g., for 250Wp modules), refer to the tables in the full PDF manual (page 10).
3.7 Communication Connection
Wi-Fi Cloud Communication (Optional):
Use the supplied communication cable to connect the inverter to the Wi-Fi module. Download and install the APP from the APP store. Refer to the "Wi-Fi Plug Quick Installation Guideline" for network setup and registration. The inverter status can then be monitored via the mobile phone APP or a computer webpage.

Figure 8: Monitoring and Control via SmartESS App, illustrating the app interface and the optional Wi-Fi/GPRS data acquisition module (purchased separately).
GPRS Cloud Communication (Optional):
Use the supplied communication cable to connect the inverter to the GPRS module, and then apply external power to the GPRS module. Download and install the APP from the APP store. Refer to the "GPRS RTU Quick Installation Guideline" for network setup and registration. The inverter status can then be monitored via the mobile phone APP or a computer webpage.
Battery Communication:
Communication between the battery and the inverter is facilitated through the battery communication interface, allowing the inverter and lithium battery to exchange information.
3.8 Final Assembly
After connecting all wirings, re-attach the bottom cover by screwing in the two screws.
4. Operating Instructions
4.1 Power ON/OFF
Once the unit is properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

Figure 9: Front view of the inverter with LCD display and control buttons.
4.2 Operation and Display Panel
The operation and display panel is located on the front of the inverter. It includes three indicators, four function keys, and an LCD display, which show the operating status and input/output power information.
LED Indicators:
| LED Indicator | Color | Status | Message |
|---|---|---|---|
| INV/AC | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4.3 LCD Display Icons
The LCD display provides various icons to indicate input source, output information, battery status, load status, and operating modes. Refer to the full PDF manual (pages 12-13) for a detailed list and description of all LCD icons.
4.4 LCD Setting
To enter setting mode, press and hold the ENTER button for 3 seconds. Use the UP or DOWN buttons to navigate through settings, and ENTER to confirm a selection or ESC to exit. The full PDF manual (pages 14-20) provides detailed tables for all configurable settings, including:
- Output source priority (Utility first, Solar first, SBU priority)
- Maximum charging current
- AC input voltage range (Appliances, UPS)
- Battery type (AGM, Flooded, User-Defined, Lithium)
- Auto restart settings for overload and over temperature
- Output frequency and voltage
- Maximum utility charging current
- Setting voltage point back to utility source
- Battery equalization settings (enable/disable, voltage, time, timeout, interval)
- GRID-tie operation mode
- Dual output functional voltage point
4.5 Display Setting
The LCD display information can be cycled by pressing the UP or DOWN keys. The selectable information includes input voltage, input frequency, PV voltage, charging current, charging power, battery voltage, output voltage, output frequency, load percentage, load in Watt, load in VA, DC discharging current, and main CPU Version. Examples of charged and discharged states, with power less than or greater than 1KW, are detailed in the full PDF manual (pages 21-24).
4.6 Operating Mode Description
The inverter supports various operating modes, including Standby, Line mode, and Grid-Tie operation. The LCD display will show different information depending on the active mode. For detailed descriptions and display examples for each mode, refer to the full PDF manual (pages 25-26).
4.7 Battery Equalization
Battery equalization is a function in the charge controller that reverses the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates. This process helps maintain battery capacity and is recommended periodically.
How to Apply Equalization Function:
First, enable the battery equalization function in LCD setting program 30. Then, you can apply this function by:
- Setting the equalization interval in program 35.
- Activating equalization immediately in program 36.
When to Equalize:
During the float stage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage. The controller will supply power to charge the battery until it reaches the equalization voltage, then maintain this voltage. The battery remains in the Equalize stage until the set equalized time expires. If the battery voltage does not reach the equalization voltage by the end of the equalized time and timeout, the charge controller will extend the time. If the battery voltage is still low after the timeout, equalization will stop, and the unit will return to the float stage. Refer to the full PDF manual (page 27) for a diagram illustrating the battery equalization process.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit
Each inverter comes with a factory-installed anti-dust kit. The inverter automatically detects this kit and uses an internal thermal sensor to adjust its temperature. This kit helps prevent dust from entering the inverter, increasing product reliability in harsh environments.
To clean the anti-dust kit:
- Loosen the screw on the top of the inverter in a counterclockwise direction.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and the dustproof case.
- After cleaning, re-assemble the dust kit back into the inverter.
NOTICE: The anti-dust kit should be cleaned every one month.
6. Troubleshooting
This section provides guidance for common issues. If problems persist after following these steps, contact a qualified service person or your local dealer.
6.1 Fault Reference Codes
The inverter's LCD display will show fault codes if an error occurs. Refer to the table below for common fault codes and their descriptions.
| Fault Code | Fault Event |
|---|---|
| 01 | Fan is locked when inverter is off. |
| 02 | Over temperature |
| 03 | Battery voltage is too high |
| 04 | Battery voltage is too low |
| 05 | Output short circuited or over temperature is detected by internal converter components. |
| 06 | Output voltage is too high. |
| 07 | Overload time out |
| 08 | Bus voltage is too high |
| 09 | Bus soft start failed |
| 51 | Over current or surge |
| 52 | Bus voltage is too low |
| 53 | Inverter soft start failed |
| 55 | Over DC voltage in AC output |
| 57 | Current sensor failed |
| 58 | Output voltage is too low |
| 59 | PV voltage is over limitation |
6.2 Warning Indicators
The inverter also provides warning indicators for non-critical conditions. Refer to the table below for warning codes and their audible alarms.
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second |
| 03 | Battery is over-charged | Beep once every second |
| 04 | Low battery | Beep once every second |
| 07 | Overload | Beep once every 0.5 second |
| 10 | Output power derating | Beep twice every 3 seconds |
| 15 | PV energy is low. | Beep twice every 3 seconds |
| E9 | Battery equalization | None |
| bP | Battery is not connected | None |
6.3 General Troubleshooting Table
For specific problems, possible causes, and recommended actions, refer to the detailed troubleshooting table in the full PDF manual (page 34).
7. Specifications
The Y&H 3.6KW Hybrid Solar Inverter offers robust performance for various solar power applications. Key specifications are summarized below. For complete details, refer to the full PDF manual (pages 31-33).
7.1 General Specifications
| Feature | 3.6KW Model | 6.2KW Model |
|---|---|---|
| Brand | Y&H | |
| Model Number | NM-ECO-LV-3.6K (for 3.6KW) | |
| Output Current | 120A | |
| Output Frequency | 50Hz/60Hz | |
| Dimensions (L*W*H) | 51cm*43cm*9cm (Product Package) | |
| Net Weight | 9.65Kg | 10Kg |
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage Temperature | -15°C to 60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
7.2 Line Mode Specifications
| Feature | Specification |
|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) |
| Nominal Input Voltage | 100Vac |
| Low Loss Voltage | 90Vac±5V (UPS); 90Vac±5V (Appliances) |
| High Loss Voltage | 145Vac±5V |
| Max AC Input Voltage | 150Vac |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) |
| Output Short Circuit Protection | Circuit Breaker |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) |
7.3 Inverter Mode Specifications
| Feature | 3.6KW Model | 6.2KW Model |
|---|---|---|
| Rated Output Power | 3.6KW | 6.2KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 100/105/110/115/120Vac±5% | |
| Output Frequency | 50Hz / 60Hz | |
| Peak Efficiency | 93% | |
| Nominal DC Input Voltage | 24Vdc | 48Vdc |
| Cold Start Voltage | 23.0Vdc | 46.0Vdc |
| No Load Power Consumption | 45W | 50W |
7.4 Charge Mode Specifications
| Feature | 3.6KW Model | 6.2KW Model |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) | 80Amp (@VI/P=100 Vac) | |
| Max. PV Array Power | 4200W | 6500W |
| Nominal PV Voltage | 240Vdc | 360Vdc |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | |
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 120Amp | 120Amp |
7.5 Grid-Tie Operation Specifications
| Feature | Specification |
|---|---|
| Nominal Output Voltage | 100/105/110/115/120VAC |
| Feed-in Grid Voltage Range | 90~150VAC |
| Feed-in Grid Frequency Range | 49~51±1Hz/59~61±1Hz |
| Nominal Output Current (3.6KW) | 30A |
| Nominal Output Current (6.2KW) | 51.7A |
| Power Factor Range | >0.99 |
| Maximum Conversion Efficiency (DC/AC) | 97% |
8. User Tips
- Voltage Compatibility: Always verify that the inverter's output voltage (110-120V AC) is compatible with your region's electrical standards before installation.
- Remote Monitoring: Consider purchasing the optional Wi-Fi or GPRS module for convenient remote monitoring and control of your inverter via the SmartESS app or a web interface.
- Battery Sizing: Ensure your battery bank is appropriately sized and of the correct type (e.g., deep-cycle lead-acid or compatible lithium batteries) for optimal performance and backup time. Refer to the "Approximate Back-up Time Table" in the full PDF manual (page 35) for guidance.
- Regular Maintenance: Clean the anti-dust kit monthly to ensure proper airflow and extend the lifespan of your inverter, especially in dusty environments.
9. Frequently Asked Questions (FAQ)
- Q: Does this inverter support grid injection?
- A: Yes, the Y&H 3.6KW Hybrid Solar Inverter supports Grid-Tie operation, allowing it to feed excess energy back into the grid. Refer to the "GRID-tie operation" settings in the LCD Setting section and the "Grid-Tie Operation Specifications" for details.
- Q: Can I connect a Wi-Fi module to this hybrid inverter?
- A: Yes, a Wi-Fi module is an optional accessory that can be connected to the inverter for remote monitoring and control via a dedicated app. Refer to the "Communication Connection" section for more information.
- Q: What is the output voltage of this inverter?