1. Safety Handling
- Avoid high humidity or extreme temperatures.
- Avoid long exposure to direct sunlight or strong ultraviolet light.
- Do not drop or expose the unit to intense vibration.
- Do not disassemble or try to repair the unit yourself.
- Do not expose the unit or its accessories to flammable liquids, gases or other explosives.
2. Technical Specifications
Wireless Connectivity
| Feature | Specification |
|---|---|
| Wi-Fi | 802.11 B/G/N20/N40 |
| BLE | Bluetooth 5.2 Low Energy |
| Wireless Type | WiFi 2.4GHz |
| RF Characteristics | Operating frequency: 2.4GHz |
Physical Specifications
| Feature | Specification |
|---|---|
| Input | 90~250V AC 50/60Hz |
| Operating Voltage | 90~250 Vac 50/60 Hz |
| Measure Range | 0.1-80A |
| Calibrated Metering Accuracy | ≤100W (Within ±2W); >100W (Within ±2%) |
| Max. Load Current | 16A Dry contact |
| Direction | Bidirectional |
| Reporting Cycle | Every 15 seconds |
| Ambient Temperature Range | -20 ~ +55 °C |
| Operating Environment Humidity | ≤90% non-condensing |
| Dimensions | 90 (L) x 35 (W) x 65 (H) mm |
| Inner Diameter of the Clamp | 1cm |
| State of Assembly | Ready-to-Go |
| Compatibility | All Compatible |
| Certification | CE, RoHS |
3. Product Overview
The PC473-R-W-TY is a 3-phase WiFi energy meter designed to monitor power consumption and production in your facility. It connects to power cables via current transformer (CT) clamps and measures real-time voltage, current, power factor, and active power. The device allows you to control its On/Off status and access real-time and historical energy data through a mobile application.
This guide provides an overview of the product and assists with the initial setup.
Image: MatSee Plus 3 Phase WiFi Energy Meter (PC473-R-W-TY) with three 80A CT clamps.
Features:
- Tuya compliant
- Support linkage with other Tuya devices
- Single/3-phase system compatible
- Measures real-time Voltage, Current, PowerFactor, Active Power and frequency
- Support Energy Usage/Production measurement
- Usage/Production trends by hour, day, month
- Lightweight and easy to install
- Support Alexa, Google voice control
- 16A Dry contact output
- Configurable on/off schedule
- Overload protection
- Power-on status setting
4. Setup
4.1 Wiring
CT Direction Check:
-
For Split Core CT: Open the clamp to see the arrow (P1→P2) or (K→L). This indicates the direction of the CT. The CT supports bi-directional sensing.
Image: Split Core Current Transformer (CT) showing the P1 to P2 direction arrow.
-
For Donut CT: The direction is from the concave surface of the CT to the flat surface. The CT supports bi-directional sensing.
Image: Donut-style Current Transformer (CT) with an arrow indicating current flow direction.
CT Connection and Direction:
- Connect the AC Input cable to a socket near the Electrical Box to power on the PC473-R according to the wiring diagram.
- Apply the CT on the electric cable and ensure the direction of the CT is correct.
- To measure energy consumption, the direction of the CT should be consistent with the direction of the electricity current flows. The power will be positive.
- To measure energy production, the direction of the CT should be opposite to the direction of the electricity current flows. The power will be negative.
Wiring Diagrams:
Follow the schematics below as an example to wire the Power Meter with Relay for different phases.
Diagram: Single Phase electricity wiring diagram. Connect N and L to the meter's N and VA terminals. Connect the CT clamp to IA+ and IA- terminals, ensuring correct direction for Load 1. An optional Inverter (DC/AC) can be connected with its own CT clamp.
Diagram: 3 Phase electricity wiring diagram. Connect N, L1/A, L2/B, L3/C to the meter's N, VA, VB, VC terminals respectively. Connect CT clamps for each phase to IA+/IA-, IB+/IB-, IC+/IC- terminals. Ensure the circuit measured by CT is in the same phase as the circuit powered by the meter.
4.2 App Download & Device Pairing
The PC473-R-W-TY uses the Smart Life app for configuration and monitoring.
-
Download the Smart Life App: Search for "Smart Life" in your App Store or App Market, or scan the QR code below to download and install.
QR Code: Smart Life App Download
- Enter Pairing Mode: Press and hold the reset button on the meter for 5 seconds until the LED indicator flashes Red 3 times quickly, then constantly blinks. This clears previous Wi-Fi information and puts the device in pairing mode.
- Add Device in App: Open the Smart Life app, click the '+' icon or 'Add Device' button in the upper right corner of the App Home page. The app will search for nearby devices. Select the PC473-R-W-TY (often listed as PC473).
- Connect to Wi-Fi: Enter your 2.4GHz Wi-Fi network name and password when prompted. The device will then connect to your Wi-Fi network.
- Confirm Connection: Once successfully added, the LED indicator will turn solid green. The device will appear in your Smart Life app.
Video: Demonstration of device pairing with the Smart Life app and live data display.
5. Operating Instructions
5.1 LED Indicator Status
The LED status provides important information about the device's connection and operation:
| LED Color | Status | Relay | Network |
|---|---|---|---|
| Green | Blinking | Wait for pairing. | |
| Green | Solid on | ON | Device has connected with cloud. |
| Red | Blinking | Wait for pairing. | |
| Red | Solid on | OFF | Device has connected with cloud. |
| Yellow / Green | Rapidly blinking alternately | ON | Device is connected to the router, but failed to connect to the cloud. |
| Yellow / Red | Rapidly blinking alternately | OFF | Device is connected to the router, but failed to connect to the cloud. |
| Yellow / Green | Slowly blinking alternately | ON | Wi-Fi has been configured, but failed to connect to router. |
| Yellow / Red | Slowly blinking alternately | OFF | Wi-Fi has been configured, but failed to connect to router. |
5.2 App Interface and Functions
Once connected, you can access various functions through the Smart Life app:
- Overview: Displays total energy usage and production, along with individual phase data (Energy Consumed A, B, C and Energy Produced A, B, C).
-
Live Data: Provides real-time readings for each phase, including Voltage, Current, Power Factor, and Active Power. You can switch between Phase A, B, and C to view specific data.
App Screenshot: Live Voltage, Current, and Active Power readings for each phase (A, B, C).
-
History Data (Electricity Statistics): Allows you to check hourly, daily, and monthly electricity consumption and production trends.
App Screenshot: Hourly, Daily, and Monthly Electricity Statistics graphs.
-
Export Data: You can export total or phase-specific energy data by selecting an export item (e.g., Total, Phase A, B, C), entering an email address, and choosing a date range (Hour, Day, Month).
App Screenshot: Data Export interface, allowing selection of data type and email for export.
-
Settings: Access various device settings including:
- Schedule: Configure on/off schedules for the relay.
- Power-on Status: Set the device's state (ON, OFF, or Remember last status) after a power outage.
- Max Power Protection: Enable and set power protection limits for each phase.
5.3 Manual Control
- ON/OFF Button: Press the physical button on the device once to switch the relay ON/OFF.
- Reset Button: Press and hold the reset button for 5 seconds until the LED indicator flashes Red 3 times quickly to clear the Wi-Fi information (energy data will not be cleared). After that, the LED indicator will constantly blink and wait for pairing.
6. Maintenance
- Keep the device clean and free from dust. Use a dry, soft cloth for cleaning.
- Ensure the device is operated within the specified ambient temperature range (-20 ~ +55 °C) and humidity (≤90% non-condensing).
- Regularly check wiring connections for tightness and signs of wear.
- Periodically check the app for firmware updates to ensure optimal performance and security.
7. Troubleshooting
7.1 Overload Protection
The device features built-in overload protection with the following conditions:
- If the continuous power exceeds 20% of the preset value (configurable in the App), the device will cut off the power supply to the load within 5 seconds.
- If the continuous value detected by the device exceeds 50% of the rated power (configurable in the App) within 1 second, the device will cut off the power supply to the load.
7.2 Common Issues & Solutions
- Incorrect Power Readings (Negative or Opposite): If the counting clamps are showing readings in the opposite direction (e.g., negative power when consuming), reverse the connection of the affected CT clamp(s). Ensure the CT direction aligns with whether you are measuring consumption or production.
-
Device Not Pairing/Connecting to Wi-Fi:
- Ensure your Wi-Fi network is 2.4GHz. The device does not support 5GHz networks.
- Check the LED indicator status (refer to Section 5.1) to diagnose network issues.
- Perform a reset (press and hold the reset button for 5 seconds) to clear previous Wi-Fi settings and re-enter pairing mode.
- Ensure your mobile device is close to the energy meter during pairing.
- Inaccurate Measurement: While the device is calibrated to within ±2%, some external factors or specific setups might affect accuracy. Ensure CT clamps are correctly installed and fully closed around the conductors. If issues persist, consult the full user manual or support.
- Cannot Export Specific Current Data: The app primarily supports exporting consumption data. Specific current data export might not be available in all versions or configurations of the app.
- Home Assistant Compatibility: The device is Tuya-compatible, which generally means it can be integrated with Home Assistant via the Tuya integration. However, specific features and stability may vary depending on the Home Assistant version and Tuya integration updates.
- Ammeter Function: Yes, the device measures and displays current (amperes) for each phase in real-time through the app, effectively functioning as an ammeter.
- 400V Three-Phase System Compatibility: The device's input voltage range is 90~250V AC. It is designed for systems within this voltage range. For 400V systems, ensure proper voltage transformers or consult a qualified electrician to confirm compatibility and safe installation.
- Recording Power Outages: The device itself does not typically record power outages from the electricity supplier. It monitors energy flow when powered. If power is lost, it will cease monitoring until power is restored. The app's activity log might show when the device goes offline/online.
- Controlling Surplus PV System Power: The device has a 16A dry contact relay that can be configured via schedules or automation rules in the Smart Life app. This allows for basic control of loads based on energy parameters, potentially for managing surplus photovoltaic (PV) system power. Advanced control logic might require integration with other smart home systems.
8. User Tips
- If you notice two counting clamps are registering in the opposite direction, simply reverse their connection to correct the readings.
- The meter is generally easy to set up, making installation straightforward for most users.
- Be aware that some users have reported that only total consumption data, not specific current data, can be exported from the app.
9. Warranty & Support
For detailed warranty information, technical support, or further inquiries, please refer to the official product documentation or contact MatSee Plus customer service.
A comprehensive user manual in PDF format is available for download: View User Manual (PDF).