1. Product Overview
The A44M T329E is an electronic control board specifically designed for AC sliding gate motors. It features a soft start function and requires a Normally Open (NO) magnetic limit switch for proper operation. This board operates on a 220V AC power input and includes a remote control for convenient operation.
Key Features:
- Soft Start Function: Ensures smooth motor operation, reducing wear and tear.
- Single Button Control: A single button on the remote can execute all commands (open, close, stop).
- Remote Control Management: Ability to delete individual remote controls.
- Adjustable Motor Working Time: Customize the motor's operational duration.
- Programmable Auto-Close: Set a specific time for the gate to automatically close.
- Power Restoration Auto-Close: Gate can be set to auto-close after a power outage and restoration.
- Infrared Detection Connector: Supports connection for infrared safety sensors.
- Compatibility: Designed exclusively for 220V AC sliding gate motors; not compatible with swing gate openers or other voltage systems.
- Limit Switch Requirement: Operates with Normally Open (NO) magnetic limit switches.
2. Specifications
| Feature | Specification |
|---|---|
| Model | A44M T329E |
| Power Input | 220V AC |
| Motor Type Compatibility | AC Sliding Gate Motors (NOT for swing gate openers) |
| Limit Switch Type | Normally Open (NO) Magnetic Limit Switch |
| Remote Control | Included (requires 1 AA battery, not included) |
| Material | ABS (housing), Green PCB |
| Dimensions (L x W x H) | 16 cm x 12 cm x 4 cm |
| Weight | 0.417 kg |
3. Setup and Installation
Important: Installation should only be performed by qualified personnel. Ensure power is disconnected before making any connections. This board is designed for 220V AC systems only.
3.1 Component Identification


3.2 Wiring Connections
Refer to Figure 1 for the location of terminal blocks. Ensure all connections are secure.
- Power Input (AC220V): Connect your 220V AC power supply to the 'N' (Neutral) and 'L' (Live) terminals. The 'PE' terminal is for Protective Earth.
- Motor Connection (MOTO): Connect your AC sliding gate motor to the 'L1', 'COM', and 'L2' terminals. 'COM' is typically the common wire, and 'L1'/'L2' are for the two directions of the motor.
- Limit Switch (LIMIT): Connect your Normally Open (NO) magnetic limit switch to the 'LIMIT' and 'COM' terminals. This board specifically requires an NO type.
- Infrared Sensor (INF): Connect infrared safety sensors to the 'INF' and 'COM' terminals.
- Control Inputs: Additional control inputs are available:
- ONE: Single button control input (Open/Close/Stop).
- STP: Stop input.
- CL: Close input.
- O.P: Open input.
- KEY: Keypad or other access control input.
- F.SW: Foot switch or similar input.
- GND: Ground for control inputs.
3.3 DIP Switch Settings (Refer to Figure 2)
The DIP switches (labeled 1-8) control various functions. Set them according to your desired operation:
| DIP Switch | Function | Description |
|---|---|---|
| 1 (RF ON/C) | Remote Control Enable/Clear | Controls remote control functionality. May be used to enable/disable or clear paired remotes. |
| 2 (LIMIT NC) | Limit Switch Type | This board requires NO limit switches. Ensure this switch is set to OFF for NO operation. |
| 3 (AUTO CL) | Auto Close Function | Toggle ON/OFF for automatic gate closing after a set delay. |
| 4 (SOFT START) | Soft Start Feature | Toggle ON/OFF for gradual motor acceleration. |
| 5 (MAX START) | Maximum Start Force | Adjusts the initial power/speed of the motor. |
| 6 (CL FORCE) | Closing Force Adjustment | Adjusts the force applied during the closing cycle. |
| 7 (OP FORCE) | Opening Force Adjustment | Adjusts the force applied during the opening cycle. |
| 8 (DIRECTION) | Motor Direction | Reverses the motor's direction if needed. |
3.4 Potentiometer Adjustments (Refer to Figure 2)
The three potentiometers (knobs) allow for fine-tuning of certain parameters:
- Motor Working Time: Adjusts the maximum duration the motor will run.
- Auto-Close Time: Sets the delay before the gate automatically closes (if AUTO CL DIP switch is ON).
- Other Adjustments: The third potentiometer may control other parameters such as remote control range or sensitivity. Adjust incrementally and test functionality.
3.5 Remote Control Pairing
To pair a remote control:
- Press the 'STUDY' button on the control board (located near the DIP switches).
- Press the desired button on your remote control.
- The board should indicate successful pairing (e.g., an LED flash or beep).
To delete a remote control, follow the board's specific instructions, which may involve holding the 'STUDY' button or using a specific DIP switch combination.
4. Operating Instructions
Once installed and configured, operate the gate using the provided remote control or wired control inputs.
- Remote Control: Press the single button on the remote to cycle through Open, Stop, Close, Stop.
- Wired Inputs: Use the 'O.P', 'CL', 'STP', or 'ONE' terminals with appropriate switches for wired control.
- Auto-Close: If enabled via DIP switch, the gate will automatically close after the set delay.
- Infrared Safety: If infrared sensors are connected, the gate will stop or reverse if an obstruction is detected during closing.
5. Maintenance
The A44M T329E control board is designed for reliable operation with minimal maintenance. However, regular checks of the overall gate system are recommended.
- Visual Inspection: Periodically check all wiring connections for signs of wear, corrosion, or looseness.
- Cleanliness: Keep the control board free from dust, moisture, and insects. Ensure the enclosure (if applicable) is sealed.
- Limit Switches: Verify that the magnetic limit switches are clean and functioning correctly.
- Safety Sensors: Test infrared safety sensors regularly to ensure they detect obstructions properly.
6. Troubleshooting
If you encounter issues with your gate opener system, perform the following basic troubleshooting steps:
| Problem | Possible Cause | Solution |
|---|---|---|
| Gate does not respond to remote. | Remote battery low/dead; remote not paired; DIP switch 1 (RF ON/C) off. | Replace remote battery; re-pair remote; check DIP switch 1 setting. |
| Gate does not open/close fully. | Limit switches misaligned or faulty; motor working time too short. | Adjust limit switch positions; check limit switch wiring; adjust motor working time potentiometer. |
| Gate reverses unexpectedly. | Infrared sensor obstructed or faulty; force settings too high/low. | Clear sensor path; check sensor wiring; adjust CL FORCE/OP FORCE DIP switches. |
| Gate motor hums but doesn't move. | Motor wiring incorrect; mechanical obstruction. | Verify motor connections (L1, COM, L2); check for physical obstructions in gate path. |
| Auto-close not working. | DIP switch 3 (AUTO CL) off; auto-close time not set. | Turn on DIP switch 3; adjust auto-close time potentiometer. |
If problems persist after performing these steps, consult a professional technician.
7. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original seller or distributor. Keep your purchase receipt as proof of purchase.