FX35 5A 35W USB Electronic Load Battery Capacity Tester User Manual

Model: FX35 | Brand: Aideepen

1. Introduction

The FX35 is a versatile 5A 35W USB Electronic Load designed for testing battery capacity, USB power sources, and other electrical components. It functions as a constant current load with adjustable resistance, featuring a clear LCD display and comprehensive protection mechanisms. This manual provides instructions for its setup, operation, and maintenance.

For a detailed PDF version of the user manual, please refer to the official document: FX35 User Manual (PDF).

2. Product Overview

The FX35 unit features a compact design with a cooling fan, an LCD screen for displaying parameters, and control buttons for settings. Key components include:

  • USB Input Port: For connecting the device to a DC5.0V power source.
  • Terminal Block (IN+/IN-): For connecting the load input (DC1.5V-25V).
  • Cooling Fan: Automatically activates for heat dissipation.
  • LCD Screen: Displays voltage, current, power, capacity, temperature, and protection codes.
  • Potentiometer (I-ADJ): For adjusting the discharge current.
  • Control Buttons (SELECT, ON/SET): For navigating menus and confirming settings.
  • RUN Indicator Light: Indicates operational status.
  • Buzzer: Provides audible alerts for protection events.
Front and back view of the FX35 USB Electronic Load
Figure 2.1: Front and back view of the FX35 USB Electronic Load, showing the fan, LCD, buttons, USB input, and terminal block on the front, and the main chip and components on the back.
Top-down view of the FX35 USB Electronic Load
Figure 2.2: Top-down view of the FX35 USB Electronic Load, showing the arrangement of the fan, LCD, buttons, potentiometer, USB input, and terminal block.

3. Specifications

Parameter Value
Load Power Supply Voltage DC5.0V (with anti-reverse connection)
Load Power Supply Current ≤ 200mA
Load Input Voltage DC1.5V-25V (with anti-reverse connection)
Load Input Current 0.00A-5.00A
Voltage Accuracy ± (1 word)
Current Accuracy ± (1 word), calibratable
Heat Dissipation Method Intelligent temperature control fan, all aluminum fan
Fan Speed 8000rpm
Working Environment Temperature -15°C to 50°C
Undervoltage Protection (LVP) Threshold Default 1.5V (adjustable 1.5V-24.5V)
Overvoltage Protection (OVP) Threshold Default 25.0V (adjustable 1.5V-25.0V)
Overcurrent Protection (OCP) Default 4.10A/5.10A (settable)
Over-power Protection (OPP) Default 25.5W/35.5W (settable)
Over-temperature Protection (OTP) Activates > 80°C
Battery Included Yes
DIY Supplies Category Electrical
Certification CE
Origin Mainland China

4. Setup

  1. Power Supply Connection: Connect a DC5.0V power source to the USB input port of the FX35. The device requires an external power supply to operate.
  2. Load Input Connection: Connect the device or power source you wish to test to the green terminal block (IN+ for positive, IN- for negative). The load input voltage range is DC1.5V-25V.
  3. Initial Power-On: After connecting the power supply and load, press the ON/SET key to start the device.
Side view of the FX35 USB Electronic Load showing connections
Figure 4.1: Side view of the FX35 USB Electronic Load, highlighting the USB input port and the green terminal block for load connection.

5. Operation

5.1. LCD Screen Display Modes

  • Normal Mode: The upstream section of the LCD displays the load input voltage and load temperature. The downstream section displays the load current, power, capacity, and discharge time.
  • Protection Mode: The LCD screen will display a specific protection code (e.g., OVP, OCP, OPP, OTP, LVP) when a protection event occurs.
  • Setting Mode: In this mode, the LCD displays each setting parameter code and its corresponding threshold value.

5.2. Load Current Adjustment

The discharge current can be adjusted by rotating the potentiometer labeled I-ADJ. Adjust this to set the desired constant current load.

Angled view of the FX35 USB Electronic Load showing potentiometer
Figure 5.1: Angled view showing the potentiometer (I-ADJ) for current adjustment, along with the fan, LCD, and buttons.

5.3. Sound and Light Alarm

  • When the load is turned ON, the RUN indicator light is continuously on, and the buzzer remains silent.
  • When the load is turned OFF, the RUN indicator light is off, and the buzzer remains silent.
  • Upon entering a protection mode, the buzzer will sound, and the RUN indicator will flash to alert the user.

5.4. Intelligent Fan Cooling

The cooling fan automatically starts when the load discharge power exceeds 10W or when the load temperature rises above 40°C. This ensures efficient heat dissipation during operation.

5.5. Discharge Capacity and Time Statistics

The device automatically tracks discharge capacity and time. Statistics begin when the load is turned ON (RUN indicator is on) and stop when the load is turned OFF (RUN indicator is off). These statistics are stored even after power-off.

  • Clearing Statistics: To clear the statistical data, press any key when the LCD screen displays discharge capacity or discharge time. It is recommended to clear previous data before starting new tests.
  • Setting Maximums (OAH/OHP): In setting mode, you can enable or disable maximum discharge capacity (OAH) and maximum discharge time (OHP) thresholds. If a threshold is set and exceeded, the load will automatically turn off, allowing for unattended discharge experiments.

5.6. Protection Mechanisms

The FX35 incorporates both hardware and software protection to ensure safe operation:

  • Hardware Protection: The module's power supply port and load input port are equipped with anti-reverse connection protection.
  • Software Protection:
    • OVP (Overvoltage Protection): Default 25.5V (adjustable). If triggered, the RUN indicator flashes, and the LCD displays "OVP".
    • OCP (Overcurrent Protection): Default 4.10A/5.10A (adjustable). If triggered, the RUN indicator flashes, and the LCD displays "OCP".
    • OPP (Over-power Protection): Default 25.5W/35.5W (adjustable). If triggered, the RUN indicator flashes, and the LCD displays "OPP".
    • OTP (Over-temperature Protection): Activates if load temperature exceeds 80°C. If triggered, the RUN indicator flashes, and the LCD displays "OTP".
    • LVP (Undervoltage Protection): Default 1.5V (adjustable). This feature is crucial for battery discharge tests, preventing over-discharge and potential battery damage. If triggered, the RUN indicator flashes, and the LCD displays "LVP".

When any software protection is triggered, the output is turned off. All settable parameters are stored in power-off memory.

6. Maintenance

  • Cleaning: Keep the device clean and free from dust, especially around the cooling fan and heatsink, to ensure optimal heat dissipation.
  • Ventilation: Ensure the device is operated in a well-ventilated area to prevent overheating.
  • Storage: Store the device in a dry environment within the specified working temperature range (-15°C to 50°C).
  • Thermal Paste (Advanced User Tip): For enhanced heat dissipation, some users may choose to clean off any residue and apply fresh thermal paste to the heatsink components. This is an optional step for advanced users.

7. Troubleshooting

Problem Possible Cause Solution
Buzzer sounds and RUN indicator flashes Device is in a protection mode (OVP, OCP, OPP, OTP, LVP). Check the LCD screen for the specific protection code. Address the condition (e.g., reduce voltage/current, allow cooling).
Cooling fan not running Load discharge power is below 10W or temperature is below 40°C. Fan only activates under specific conditions. This is normal operation. If conditions for activation are met (power > 10W or temp > 40°C) and fan still doesn't run, check fan connection or for obstructions.
No display or device not turning on No external DC5.0V power supply connected or ON/SET key not pressed. Ensure a stable DC5.0V power source is connected to the USB input. Press the ON/SET key to power on.
Inaccurate voltage/current readings Calibration may be required or external factors affecting measurement. The device supports current accuracy calibration. Refer to the PDF manual for detailed calibration procedures if available. Consider using a trusted external tester for verification.

8. User Tips

  • External Power Supply: Remember that the FX35 requires an external DC5.0V power supply to function. It will not operate without it.
  • Real-time Adjustments: The settings, including current and protection thresholds, can be adjusted on the fly during operation.
  • Verification with External Testers: For critical measurements or verification, it is advisable to use a trusted external voltage/current tester in conjunction with the FX35.
  • Fan Activation: The cooling fan is designed to activate automatically when the load power exceeds 10W or the temperature reaches 40°C to maintain optimal operating conditions.

9. Warranty and Support

This product is covered by a standard manufacturer's warranty against defects in materials and workmanship. For warranty claims, technical support, or further assistance, please contact your retailer or the manufacturer directly.

Please retain your proof of purchase for warranty purposes.