1. Safety Information and Precautions
This guide provides essential information for the safe and effective use of your Variable Frequency Drive (VFD). Please read carefully before installation, operation, or maintenance.
1.1. Electrical Safety
- Extreme care must be taken when working with the VFD or within its vicinity. The voltages used can cause severe electrical shock or burns and are potentially lethal.
- Only authorized and qualified personnel should work on the VFD.
1.2. Machine/System Design and Safety of Personnel
- Machine/system design, installation, commissioning, startup, and maintenance must be performed by personnel with the necessary training and experience.
- The VFD uses high voltages and currents (including DC) and stores a high level of electrical energy in the DC bus capacitors, even after power is turned OFF. These high voltages are potentially lethal.
- The VFD is NOT intended for safety-related applications. The electronic "STOP & START" control circuits should not be relied upon for personnel safety.
- Mains power supply must be disconnected by an electrical safety isolation device before accessing internal VFD parts.
- Safety risk assessments of the machine or process system using the VFD must be conducted by the user or system integrator/designer.
1.3. Electrical Installation - Safety
- Electrical shock risk is always present within a VFD, including the output cable leading to the motor terminals.
- If dynamic brake resistors are fitted externally, ensure cables are double insulated as DC voltages can be 300VDC to 650VDC.
- A mains power supply isolation switch should be fitted to the VFD.
- Always disconnect mains power via the isolation switch before removing any VFD cover or performing service.
- Allow at least 10 minutes after disconnecting AC supply for stored charge in DC bus capacitors to dissipate through internal bleed resistors.
- Whenever possible, check the DC bus voltage with a VDC meter before accessing the VFD bridge.
2. Product Overview and Specifications
The ELECTESLA ES280 Mini VFD is a versatile variable frequency drive inverter designed for precise motor speed control.
2.1. General Specifications
| Attribute | Value |
|---|---|
| Brand Name | ELECTESLA |
| Model Number | ES280 |
| Type | DC/AC Inverters |
| Input Voltage | 3phase 380-440V |
| Output Voltage | 3phase 380-440V |
| Output Power | 4KW/5.5KW |
| Output Frequency | 0-400Hz |
| Output Current | 9.4A/12.6A |
| Output Type | triple |
| Size | 216*101*151mm |
| Weight | 1.8kg |
| Certification | CE |
| Customization | Yes |
2.2. Product Views


3. Installation and Wiring
3.1. General Wiring Diagram


3.2. Terminal Function Instruction
| Terminal | Function | Setting and Instruction |
|---|---|---|
| R, S, T | VFD Input (Three-phase 220V/380V Model connect with R, S, T terminals; Single-phase 220V Model connect with L, N terminals) | An air switch should be used as the over-current protection device. For LCDI, choose a sensitivity level above 200mA and reaction period last more than 100ms. |
| U, V, W | VFD output, connected with electrical machine | To reduce leakage current, the connection wire should not be over 50 meters. |
| P+, PB | Connected with braking resistor | Choose an appropriate braking resistor according to the list. |
| PE | Connected with the ground | The VFD should be well-grounded. |
| X1 | Digital input X1 | Set according to parameter F5.02, defaults to FWD. |
| X2 | Digital input X2 | Set according to parameter F5.03, defaults to REV. |
| X3 | Digital input X3 | Set according to parameter F5.04, defaults to the first multistage speed. |
| X4/485+ | Digital input X4 RS485+ | If not RS485-, set according to F5.05, defaults to the second multistage speed. |
| X5/485- | Digital input X5 RS485- | If not RS485+, set according to F5.06, defaults to external RST. |
| GND | Signal public terminal | Zero potential of analog input signal. |
| AVI | 0-10V signal input | 0-10V, input resistance: >50KΩ. |
| 10V | Frequency Setting potentiometer power source | +10V, maximum 10mA. |
| ACI | 0-20mA analog input | 0-20mA, input resistance: 100Ω. |
| AO | Analog output | Set according to parameter F6.10. |
| TA, TB, TC | Relay output | Contact rating: AC 250V/3A, DC 24V/2A. |
3.3. Connecting an External Potentiometer
This video demonstrates how to connect and use an external potentiometer to control the frequency of the VFD inverter. It covers the terminal connections and parameter settings required.
Wiring Steps:
- Middle terminal of potentiometer: Connect to the AVI terminal of the inverter.
- Left terminal of potentiometer: Connect to the 10V terminal of the inverter.
- Right terminal of potentiometer: Connect to the GND terminal of the inverter.
If the frequency increase or decrease does not match the direction of rotation of the knob, swap the GND and 10V wiring connections on the inverter.
Parameter Settings for Potentiometer Control:
- Press the
PRGkey. - Use the up arrow to find the
F0parameter group. - Press
ENTER. - You will see
F0.00. Use the up arrow to change the value to3(for potentiometer control). - Press
ENTERto confirm. - Press the
PRGkey to return to the main display.
4. Operating Panel
The VFD features an intuitive keyboard panel for control and monitoring.
4.1. Appearance of Keyboard Panel

4.2. Key Functions
| Item | Symbol | Function |
|---|---|---|
| Digital tube display | 8.8.8.8 | To display frequency or parameter values using LED. |
| Parameter setting key | PRG | Used to read and modify parameter groups, press to enter a parameter group or display its value. |
| Enter keys | ENTER | Press this key to enter the next level menu and confirm setting parameters. |
| Increment | ▲ | To increase parameter number or parameter set value. |
| Decrement | ▼ | To reduce parameter number or parameter set value. |
| RUN | RUN | Starts the VFD when using the operating panel control mode. |
| STOP | STOP | Stops the VFD when running. Performs a reset operation when in FAULT status. |
| Speed control knob | ○ | To adjust frequency. |
| Multifunction keys | FUNC | Default for VFD jog operation. |
| Shift keys | ▶ | Cyclically switches display parameters for operation/shutdown monitoring. In programming state, changes the modification bit of setting data. |
To return to the original interface after setting parameters:
- Power off, then power on again.
- Press the
PRGbutton twice or three times.
5. Basic Operation
5.1. VFD Running Command Mode Setting
The VFD operation command mode is set by parameter F0.02. There are three types:
- Panel control start and stop: Set
F0.02 = 0. Use the green RUN button to start and the red STOP button to stop. Default is forward rotation. Reverse rotation can be set via input terminals X1-X5 (reverse setting is 2). - Terminal control start/stop: Set
F0.02 = 1. This mode uses external terminals for control. - Communication control start/stop: This mode uses communication protocols for control.
5.2. VFD Frequency Setting Method Selection
The VFD frequency setting mode is configured via parameter F0.03:
F0.03 = 4: Running frequency is set by the potentiometer.F0.03 = 2: Running frequency is input by AVI (0-10V, can be connected to a potentiometer).F0.03 = 3: Running frequency is input by ACI (0-20mA).F0.03 = 1: Controlled by the external terminal (digital value set to increase/decrease frequency).
6. Parameter Settings
The VFD has extensive parameter settings organized into groups (F0, F1, F2, etc.) to customize its operation. Below are some key parameters from the F0 group. For a complete list and detailed descriptions of all parameters, please refer to the full PDF user manual.
6.1. F0 Group - Basic Running Parameters (Examples)
| Function code | Name | Description | Setting range | Factory default |
|---|---|---|---|---|
| F0.00 | VF Power | The current power of the VFD. | 0.00-99.99KW | Model setting |
| F0.01 | Control Mode | 0: V/F Control, 1: SVC mode | 0-1 | 0 |
| F0.02 | Running order channel selection | 0: Keyboard command channel, 1: Terminal command channel, 2: Communication command channel (Need RS485) | 0-1/0-2 | 0 |
| F0.03 | Frequency given source channel A | 0: Digital setting (UP/DOWN terminals), 1: Digital setting 2 (UP/DOWN terminals), 2: AVI analog setting (0~10V), 3: ACI analog setting (0~20mA), 4: Keyboard potentiometer setting, 5: Multi-speed setting, 6: Simple PLC, 7: PID control, 8: Communication (Need RS485) | 0-7/0-8 | 4 |
| F0.07 | Digital frequency setting | The set value is the initial value of frequency digital given. | 0-MAX Frequency | 50.00Hz |
| F0.08 | Max frequency output | The maximum output frequency the inverter allows to output, benchmark for acceleration/deceleration. | Upper limit frequency - 400.00Hz | 50.00Hz |
| F0.09 | Upper limit frequency | The operating frequency cannot exceed the maximum output frequency. | Lower limit frequency - Max frequency | 50.00Hz |
For a comprehensive list of all parameter groups (F0-FC) and their detailed descriptions, please refer to the official user manual PDF: ELECTESLA ES280 VFD User Manual (PDF).
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your VFD inverter. Always disconnect power before performing any maintenance.
- Cleaning: Keep the VFD unit clean and free from dust and debris. Ensure cooling fans and air ducts are not blocked.
- Inspection: Periodically inspect wiring connections for tightness and signs of wear or damage.
- Cooling Fan: Check that the cooling fan is operating correctly. If it's not running, check its power supply and the fan itself.
- Environment: Ensure the VFD is operated within its specified environmental conditions (temperature, humidity). Avoid small spaces around the VFD that could hinder cooling.
8. Troubleshooting
This section provides common fault codes, their possible reasons, and suggested troubleshooting steps.
| Fault code | Fault descriptions | Possible reasons | Troubleshooting |
|---|---|---|---|
| OU1(1) | Over voltage in Acc process | Abnormal supply voltage, The driver is restarted with a rotating motor | Check the power supply, Start after setting as DC braking, or rotational |
| OU1(2) | Over voltage in Dec process | Too short Dec time, Abnormal of supply voltage | Prolong the Dec time, Check the power supply |
| OCC1(4) | Hardware Over-current in Acc process | Too short Acc time, VFD power is too small, V/F curve is not suitable, IGBT module damaged | Prolong the Acc time, Select a higher power drive, Adjust V/F curve or torque boost, Contact suppliers for service |
| OCC3(6) | Hardware Over-current in constant speed | Sudden change or abnormal of load, VFD power is too small, IGBT module damaged | Check the load or reduce the change of the load, Select a higher power drive, Contact suppliers for service |
| EFO(10) | Power module failure | VFD instantaneous overcurrent, The control board is abnormal or has serious interference, Damaged power device | Refer to overcurrent countermeasures, Contact suppliers for service |
| LU(13) | Undervoltage | Abnormal input voltage, Contactor does not pick up | Check the power supply voltage, Contact suppliers for service |
| OH(14) | Overheat | Air duct blocked, Cooling fan does not run | Clean and unclog airways, Check the fan's power supply and the fan itself |
| OL1(15) | VFD overload | Improper V/F curve or torque boost settings, The grid voltage is too low, The motor is blocked or the load suddenly changes too much, Motor overload protection factor setting is incorrect | Adjust the V/F curve and torque boost amount, Check grid voltage, Check the load, Correctly set the motor overload protection factor |
| FBL(19) | PID feedback is lower than the lower limit | Loose PID feedback line, The feedback amount is less than the disconnection detection value | Check feedback connection, Adjust the detection input threshold |
| EEEP(21) | EPROM read / write errors | EEPROM malfunction | Contact suppliers for service |
| SPO | Output phase loss fault | The wiring from the inverter to the motor is abnormal, The three-phase output of the inverter is unbalanced, Abnormal drive board, Module Abnorma | Troubleshoot wiring, Check whether the three-phase winding of the motor is normal, Contact suppliers for service |
9. User Tips
No specific user tips were available from provided reviews or Q&A content. Always ensure proper wiring and parameter configuration for optimal performance.
10. Warranty and Support
The ELECTESLA ES280 Mini VFD Inverter comes with an 18-month warranty.
For detailed technical support, advanced parameter configurations, or specific troubleshooting not covered in this manual, please refer to the complete PDF user manual or contact ELECTESLA customer support.
Official User Manual (PDF): Download PDF