1. Overview
Thank you for purchasing the new UNI-T UT200+ series clamp meters. This manual provides essential information for safe and correct use of your device. Please read it thoroughly before operation and keep it for future reference.
The UT203+/UT204+ models are portable True RMS AC/DC clamp meters with automatic ranging capabilities. Designed according to EN61010-1 CAT II 600V/CAT III 300V safety standards, they offer full-function protection for a safe and reliable measurement experience. These meters are ideal for electrical measurements up to 1000A current.

2. Key Features
- True RMS measurement for accurate readings on non-sinusoidal waveforms.
- Audio-visual Non-Contact Voltage (NCV) electric field detection.
- High voltage frequency range: 10Hz-60kHz.
- Low voltage frequency range: 60Hz-10MHz.
- AC/DC Current Measurement: UT203+ (40A, 400A), UT204+ (60A, 600A) with 45Hz-400Hz frequency response.
- Live/Neutral wire detection (UT204+ only).
- ACA/DCA mode memory function for current measurement.
- Large Capacitance Measurement: UT203+ (up to 40mF), UT204+ (up to 60mF).
- Temperature Measurement: UT204+ only, range -40°C to 1000°C (-40°F to 1832°F).
- Large LCD with HD display and backlight function for clear readings.
- Fast refresh rate (3 times/s).
- Full-function false detecting protection up to 600V (3.6kVA) energy surge overvoltage and overcurrent alarm.
- Low power consumption, extending battery life up to 400 hours.
- Large jaw design (up to 28mm) suitable for various wire measurements.
- Industrial-grade soft buttons for durability and ease of use.


3. Safety Instructions
The meter is designed according to EN61010-1, 61010-2-032/033 and EN61326-1 safety standards, conforming to double insulation, CAT II 600V, CAT III 300V, and pollution grade II. Improper use may weaken or lose the provided protection.
General Safety Guidelines:
- Do not use the tester or test leads if they appear to be damaged.
- Do not use the meter if the rear or battery cover is open.
- Keep fingers behind the finger guard and do not touch live parts to prevent electric shock.
- The function switch should be correctly set before measurement. Do not switch scales during measurement to avoid damage.
- Do not apply AC/DC voltage over 600V to any terminal.
- Use caution to avoid shock hazard when working with voltages above DC 60V or AC 30Vrms.
- Never input voltage or current exceeding the specified limit.
- Before measuring resistance, diode, and continuity, disconnect all power and fully discharge all capacitors.
- Replace batteries when the "battery symbol" appears on the LCD. Remove batteries if the meter is idle long-term.
- Do not change the internal circuit of the meter.
- Do not expose the meter to high temperature/humidity, flammable, explosive, or intense magnetic environments.
- Clean the meter casing with a soft cloth and mild detergent. Do not use abrasives or solvents.
Symbols:
- ▲: Caution, possibility of electric shock
- ~: Alternating current
- ---: Direct current
- Π: Equipment protected throughout by double insulation or reinforced insulation
- ⏚: Earth (ground) terminal
- ⚠: Warning or caution
4. Standard Accessories
Upon opening the package, please check for the following items. If any are missing or damaged, contact your supplier immediately:
- Clamp Meter (Host): 1 pc
- User Manual: 1 pc
- Test Leads: 1 pair
- K-type Temperature Probe: 1 pc (Only UT204+)
- Cloth Bag: 1 pc

5. Setup
Battery Installation
The meter requires two AAA 1.5V batteries (not included). To install or replace batteries:
- Turn off the meter and remove the test leads from the input terminals.
- Unscrew the screw of the battery compartment on the back of the meter.
- Remove the battery cover and take out any used batteries.
- Insert two new AAA batteries according to the polarity indications.
- Replace the battery cover and tighten the screw.

Test Lead Connection
For most measurements (voltage, resistance, continuity, diode, capacitance, temperature), insert the red test lead into the "VΩHz" jack and the black test lead into the "COM" jack. Ensure secure connections.
6. Operating Instructions
The UT200+ series clamp meters offer a variety of measurement functions. Always ensure the function dial is set to the correct measurement mode before connecting to a circuit.
General Operation:
- Function Dial: Rotate the central dial to select the desired measurement function (e.g., AC/DC Current, AC/DC Voltage, Resistance, etc.).
- SELECT Button: In composite scales, press this button to switch between corresponding functions or ranges.
- HOLD/BACKLIGHT Button: Short press to enter/exit data hold mode. Long press (about 2 seconds) to turn on/off the backlight.
- MAX/MIN Button: Short press to enter maximum/minimum measurement mode (valid for ACV/DCV, ACA/DCA, °C/°F, resistance, and capacitance scales). Long press to exit.
- REL Button: Press to store the current reading as a reference for relative measurements (valid for ACV/DCV, DCA, °C/°F, and capacitance scales).
- Auto Power Off: The meter will automatically power off after 15 minutes of inactivity. Press any button or turn the switch to OFF and then ON to wake it up.

Measurement Demonstrations:
Video 1: Product demonstration showing various measurement functions.
AC/DC Current Measurement:
Select the corresponding current range. Press the trigger to open the clamp jaws and fully enclose one conductor. Only one conductor can be measured at a time. Do not insert test leads during current measurement. For DC current, press REL to zero before measurement.
AC/DC Voltage Measurement:
Select the corresponding function scale. Insert the red test lead into the "VHz" jack and the black into the "COM" jack. Connect test leads to both ends of the measured object. Do not input voltage above 600V.
Resistance Measurement:
Select the resistance function. Connect test leads to the component. Disconnect all power and fully discharge capacitors before measuring.
Diode Measurement:
Select the diode function. Connect test leads across the diode. Disconnect all power and fully discharge capacitors before measuring.
Continuity Test:
Select the continuity function. Connect test leads across the circuit. A continuous beep indicates continuity. Disconnect all power and fully discharge capacitors before testing.
Capacitance Measurement:
Select the capacitance function. Connect test leads across the capacitor. Disconnect all power and fully discharge capacitors before measuring. (UT202+, UT203+, UT204+, UT202A+ ONLY)
Temperature Measurement:
Select the temperature function. Insert the K-type thermocouple into the meter, fix the probe on the measured object, and read the stable value. (UT202+, UT204+ ONLY)
NCV (Non-Contact Voltage) Measurement:
Bring the NCV sensor (top of the clamp head) close to a charged electric field. The LCD will display segments and the buzzer will beep, with red LED flashing, indicating voltage detection. The sensitivity has two levels: EFHI (high) and EFLo (low).
LIVE Wire Detection (UT204+ ONLY):
Select the LIVE function. Insert the red test lead into the "VHz" jack, leave the black test lead suspended, and use the red test lead to touch the socket or bare wire to distinguish live/neutral wire. "LIVE" will be displayed for live wire, and "---" for neutral or uncharged objects.
Home Appliance Current Usage with Splitter (UT-LS15-US):
The UT200+ series can be used with a splitter (UT-LS15-US) to separate live and ground wires, allowing convenient measurement of home appliance current usage.
7. Maintenance
General Maintenance:
- Clean the meter casing with a soft cloth and mild detergent. Do not use abrasives or solvents.
- Do not use the tester or test leads if they appear to have any abnormality.
- Maintenance and service must be implemented by qualified professionals or designated departments.
Battery Replacement:
When the "battery symbol" appears on the LCD, replace the batteries to ensure measurement accuracy. Refer to the "Battery Installation" section for detailed steps.
Warning: Before opening the rear cover of the meter, remove test leads to avoid electric shock.
8. Troubleshooting
If you encounter issues with your UNI-T UT200+ series clamp meter, consider the following:
- No display or erratic readings: Check battery levels and replace if necessary. Ensure test leads are properly connected.
- Inaccurate current readings: Ensure only one conductor is enclosed by the clamp jaws. For DC current, use the REL button to zero the display before measurement.
- "OL" display: Indicates an overload or that the measured value exceeds the maximum range of the selected function. Switch to a higher range if available, or verify the circuit conditions.
- No continuity beep: Check if the test leads are short-circuited. If the resistance is over 0.5Ω when short-circuited, check for loose connections or damaged test leads.
- Meter not turning on: Verify battery installation and charge.
For persistent issues, refer to the detailed troubleshooting section in the full PDF manual or contact customer support.
9. Specifications
General Specifications:
- Max LCD display counts: 4099 (UT203+), 6099 (UT204+)
- Polarity display: Auto
- Overload display: "OL" or "-OL"
- Low battery indication: Battery symbol
- Low battery shutdown prompt: "Lo.bt" appears on LCD, buzzer beeps 3 times, meter shuts down.
- Test position error: ±1.0% additional error if source not at center of clamp jaws.
- Drop protection: 1m
- Maximum jaw opening: 28mm diameter
- Battery: AAA 1.5V battery x 2
- Auto power off: 15 min (adjustable)
- Dimensions: 215mm × 63.5mm × 36mm
- Weight: About 235g (including batteries)
- Altitude: 2000m
- Operating temperature and humidity: 0°C-30°C (≤80%RH), 30°C-40°C (≤75%RH), 40°C-50°C (≤45%RH)
- Storage temperature and humidity: -20°C~+60°C (≤80%RH)
Detailed Technical Specifications:

For a comprehensive breakdown of all technical specifications, including accuracy and ranges for each model (UT201+, UT202+, UT202A+, UT203+, UT204+), please refer to the table above and the full PDF manual.
10. Warranty & Support
Limited Warranty:
UNI-T guarantees that this product is free from defects in material and workmanship for one year from the purchase date. This warranty does not cover damages caused by accident, negligence, misuse, modification, contamination, or improper handling. For warranty service, please contact your seller directly.
UNI-T is not responsible for any special, indirect, incidental, or subsequent damage or loss caused by using this device.
Manufacturer Contact:
UNI-TREND TECHNOLOGY (CHINA) CO., LTD.No.6, Gong Ye Bei 1st Road,
Songshan Lake National High-Tech Industrial Development Zone,
Dongguan City, Guangdong Province, China
Tel: (86-769) 8572 3888
Website: www.uni-trend.com
For additional information and detailed instructions, you may refer to the official user manual PDF: View User Manual (PDF).
11. User Tips
- Batteries: Remember that 2 AAA batteries are required for operation and are not typically included in the package. It's advisable to have them ready for immediate use.
- Versatility: This is a very versatile and lightweight tool, suitable for a wide range of electrical measurements.
- Pouch Case: The included pouch case is useful for protecting the device and keeping it handy.