1. Introduction
The Gaqqee KWS-DC28 is a multi-function digital voltmeter and ammeter designed for precise measurement of DC voltage, current, and power. Featuring a 0.96-inch TFT HD color display, it provides real-time data on power status, voltage, current, capacity, and more. This device is compatible with a variety of DC port devices, making it ideal for monitoring computer equipment, power tools, routers, and other electronics.
This manual provides detailed instructions for the safe and effective use of your KWS-DC28 meter. Please read it thoroughly before operation.
2. Safety Information
- Ensure the input voltage and current are within the specified ranges (DC 4-30V, 0-12A) to prevent damage to the device or connected equipment.
- Do not disassemble or modify the device.
- Keep the device away from water, moisture, and extreme temperatures.
- Handle with care to avoid physical damage.
- This device is intended for measuring DC circuits only. Do not connect to AC power.
3. Package Contents
- KWS-DC28 Tester x 1
4. Product Overview
The KWS-DC28 features a compact design with a clear TFT HD display and standard DC input/output ports.
Figure 4.1: Front and Back View of KWS-DC28
Figure 4.2: Interface Tester Overview
Video 4.1: KWS-DC28 Product Rotation View
5. Specifications
| Parameter | Value |
|---|---|
| Voltage Range | DC 4-30V |
| Current Range | 0-12A |
| Power Range | 0-360W |
| Capacity Range | 0-6666666mAh |
| Energy Range | 0-999999mWh |
| Timing Range | 0-99 hours |
| Display Type | 0.96 inch TFT HD Color Screen |
| Dimensions | 60 x 20 x 12 mm (2.36 x 0.79 x 0.47 inches) |
| Certification | CE |
| Battery Included | No |
| DIY Supplies | Electrical |
6. Setup
The KWS-DC28 is designed for simple inline connection. Follow these steps to set up the device:
- Identify the DC power source and the device you wish to monitor.
- Connect the male head (input) of the KWS-DC28 to your DC power source (e.g., power adapter).
- Connect the female head (output) of the KWS-DC28 to the device you want to power and monitor.
- Once connected, the display will automatically turn on and show real-time measurement data.
Figure 6.1: KWS-DC28 Connection Ports
7. Operating Instructions
The KWS-DC28 provides real-time monitoring and data recording with intuitive button controls.
7.1 Display Modes
The device features two main display pages. Use the button on the side of the meter to switch between them:
- Single Click: Each single click of the button will cycle between the two main display pages.
- Double Click: A double click of the button will flip the interface, transforming the displayed information (e.g., showing maximum values).
Figure 7.1: Button Functionality for Display Pages
7.2 Real-time Data Display
The 0.96-inch TFT HD display shows various parameters simultaneously:
- Voltage: Current DC voltage (e.g., 19.80V)
- Current: Current DC amperage (e.g., 5.000A)
- Power: Real-time power consumption (e.g., 99.00W)
- Timing: Elapsed time of measurement (e.g., 00:05:28T)
- Capacity: Accumulated charge capacity (e.g., 000043mAh)
- Energy: Accumulated energy consumption (e.g., 000254mWh)
- CPU Temperature: Internal CPU temperature (e.g., CPU:30°C)
7.3 Data Recording
The device can record the single highest values for power, maximum current, and maximum voltage detected during a measurement session.
8. Display Information Details
Refer to the diagram below for a detailed breakdown of the display elements and their corresponding functions:
Figure 8.1: KWS-DC28 Display and Port Diagram
- Voltage (4-30V)
- Current (0-12A)
- Power (0-360W)
- Timing (0-99 hours)
- Capacity (0-6666666mAh)
- Energy (0-999999 mWh)
- Current direction marker
- CPU temperature
- Recorded single maximum power
- Recorded single maximum current
- Recorded single maximum voltage
- Current direction marker
- 5.5*2.5/2.1 male head (Input)
- 5.5*2.5/2.1 female head (Output)
9. User Tips
Based on general user feedback, the KWS-DC28 is appreciated for its ease of use and clear display. While no specific operational tips were provided by users, here are some general recommendations:
- Always ensure secure connections to prevent intermittent readings or damage.
- Monitor the CPU temperature during prolonged high-power measurements.
- Utilize the double-click function to quickly review peak performance data for your devices.
10. Troubleshooting
- No Display: Ensure the device is correctly connected to a DC power source within the 4-30V range. Check for loose connections.
- Inaccurate Readings: Verify that the connections are secure and clean. Ensure the load is within the specified current and power limits.
- Device Overheating: If the CPU temperature is consistently high, reduce the load or ensure adequate ventilation around the device. Prolonged overheating can lead to damage.
- Button Unresponsive: Ensure the button is not stuck. If the issue persists, disconnect and reconnect the power.
11. Maintenance
- Keep the device clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Avoid exposing the device to harsh chemicals or solvents.
- Store the device in a cool, dry place when not in use.
12. Warranty and Support
For detailed warranty information and technical support, please refer to the official product documentation or contact the seller directly.
An electronic version of the user manual (PDF) is available for download: View User Manual (PDF)