1. Introduction
Thank you for choosing the WESA MZ-05-YIN Wall Mounted Power Socket. This manual provides essential information for the safe installation, operation, and maintenance of your new electrical outlet. Please read this manual thoroughly before installation and keep it for future reference.

Figure 1: WESA MZ-05-YIN Wall Mounted Power Socket
2. Safety Information
WARNING: Risk of electric shock. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker before beginning any electrical work.
- Installation should be performed by a qualified electrician or a competent person.
- Ensure the power supply is completely disconnected before installation, maintenance, or repair.
- Do not exceed the rated current and voltage of the socket.
- Do not use the socket in wet or damp conditions unless specifically rated for such environments.
- Keep children away from electrical outlets.
- This product is designed for indoor use only.
- The socket features anti-flame retardant material for enhanced safety.

Figure 2: Anti-flame retardant material for safety
3. Package Contents
Please check the package for the following items:
- 1 x WESA MZ-05-YIN Wall Mounted Power Socket
- Mounting Screws (typically included)
4. Setup and Installation
Before you begin, ensure you have the necessary tools:
- Screwdriver (Phillips or Flathead, depending on screw type)
- Wire Strippers
- Voltage Tester
- Drill (if mounting to a wall without existing box)
Installation Steps:
- Turn Off Power: Locate the circuit breaker that controls the power to the installation area and switch it OFF. Use a voltage tester to confirm that the power is off at the wires where you intend to install the socket.
- Prepare Mounting Location: If replacing an existing socket, carefully remove the old unit. If installing new, mark the desired location on the wall. Refer to the dimensions diagram below for precise measurements.
- Mount the Base: Secure the socket's base to the wall using the provided mounting screws. Ensure it is level and firmly attached.
- Wire Connections:
Important: This model is specified as 'Non-Grounding' for certain configurations. Ensure you connect wires according to local electrical codes and the specific variant you have.
- Carefully strip about 1/2 inch (12-15mm) of insulation from the ends of the Live (usually brown or red) and Neutral (usually blue or black) wires from your electrical supply.
- Connect the Live wire to the terminal marked 'L' (Live).
- Connect the Neutral wire to the terminal marked 'N' (Neutral).
- Tighten all terminal screws securely to prevent loose connections.
- Attach the Cover: Once wiring is complete and secure, carefully position the socket cover over the base and fasten it with the retaining screws. Do not overtighten.
- Restore Power: Go back to your circuit breaker panel and turn the power back ON.
- Test: Plug a small appliance or a lamp into the newly installed socket to ensure it is functioning correctly.

Figure 3: Dimensions for various socket configurations (e.g., 2 Socket No Ground: 104mm x 64mm x 32mm)
Video 1: Product overview and rotation
5. Operating Instructions
Once installed and tested, the WESA MZ-05-YIN power socket operates like any standard electrical outlet:
- Insert the plug of your appliance firmly into the socket.
- Ensure the appliance's power requirements do not exceed the socket's rated capacity (16A, 250V).
- To disconnect, pull the plug directly from the socket; do not pull by the cord.
6. Maintenance
- Cleaning: Disconnect power before cleaning. Wipe the surface of the socket with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture.
- Inspection: Periodically inspect the socket for any signs of damage, cracks, discoloration, or loose connections. If any issues are found, disconnect power and have it inspected by a qualified professional.
- Safety: Ensure no foreign objects are inserted into the socket openings.
7. Troubleshooting
No Power from Socket:
- Check Circuit Breaker: Verify that the circuit breaker supplying power to the socket has not tripped. Reset it if necessary.
- Check Connections: If the breaker is on and there's still no power, turn off the power at the breaker and carefully inspect the wiring connections within the socket. Ensure all wires are securely fastened to their terminals.
- Test with Another Appliance: Try plugging in a different, known-working appliance to rule out an issue with your original appliance.
- Consult a Professional: If the problem persists after these steps, there may be an issue with your household wiring or the socket itself. Contact a qualified electrician for assistance.
8. Specifications
| Feature | Specification |
|---|---|
| Brand Name | WESA |
| Model Number | MZ-05-YIN |
| Material | Plastic |
| Rated Current | 16A |
| Socket Type | Socket 220V (EU Standard) |
| Installation Type | Wall Mounted |
| Grounding | Non-Grounding (for specific variants) |
| Application | Residential / General-Purpose |
| Shape | Rectangular |
| Standard Dimensions | 104*64*32mm (for 2 Socket No Ground variant) |
| Backlight/Indication | Not applicable |
| Extension Cable Length | None |
| Origin | Mainland China |
| Certification | CE, RoHS, WEEE |
9. User Tips
- Always ensure the power is off at the circuit breaker before attempting any installation or inspection.
- If you are unsure about any step of the installation process, it is highly recommended to consult a qualified electrician.
- Regularly check your electrical outlets for any signs of wear or damage to ensure continued safety.
10. Warranty and Support
For warranty information and technical support, please refer to the seller's terms and conditions or contact your point of purchase. Keep your proof of purchase for any warranty claims.
An additional user manual in PDF format may be available for download from the product's original listing page: View User Manual (PDF)