1. Introduction
The Diymore KWS-230x Series DC Voltage Ammeter Power Meter is a versatile Type-C tester designed for real-time monitoring of various electrical parameters. Equipped with a high-definition display and a 12A high current terminal, this device offers stable and accurate measurements for a wide range of applications, including cell phone and computer charging capacity recording.
2. Key Features
- High-Definition Display: Features a 0.96-inch TFT high-definition display (some models may feature 0.77" OLED or 1.06" TFT) for clear visibility.
- High Current Terminal: Equipped with a 12A high current terminal for stable performance.
- Real-time Monitoring: Monitors voltage, current, power, capacity, electrical energy, timing, and CPU temperature.
- Intuitive Control: Single click to change pages, double click to rotate the screen direction.
- Intelligent Recognition: Automatically records the highest power, highest voltage, and maximum current during operation.
- Bidirectional Current Testing: Supports testing current flow in both directions.
- Fast Charging Support: Compatible with various fast charging protocols including PD2.0, 3.0, PPS, QC2.0, 3.0, FCP, SCP, AFC, PE, DASH VOOC, and Super VOOC.
- Data Saving: Supports data saving in case of power failure and offline logging access.
- Durable Design: CNC metal case provides dustproof and drop-proof protection.
3. Specifications
3.1 KWS-2301C
- Voltage Range: DC 4-30V
- Current Range: 0-12A
- Timing: 0-99 hours
- Power: 0-360W
- Capacity: 0-99999MAH
- Electricity: 0-99999WH
- Ambient Temperature: 50°C
- Size: 41 x 16 x 9 mm
3.2 KWS-2302C
- Voltage Range: DC 4-30V
- Current Range: 0-12A
- Timing: 0-99 hours
- Power: 0-360W
- Capacity: 0-9999mAh
- Electricity: 0-99999Wh
- Product Size: 50.6 x 18 x 9 mm
3.3 KWS-2303C
- Voltage Range: DC 4-30V
- Current Range: 0-12A
- Power: 0-360W
- Capacity: 0-6666666mAh
- Power: 0-999999Wh
- Timing: 0-99 hours
- Product Size: 53 x 20 x 9 mm
3.4 General Specifications
- Display Type: Digital Only
- Accuracy Class: 0.01
- Power Supply: DC
- Power Source: DC
- Certification: CE
- Data Record: Yes
- Battery Included: No
4. Setup
- Connect to Power Source: Plug the Type-C male connector of the power meter into your power source (e.g., wall charger, power bank, computer USB-C port).
- Connect Device: Plug your device (e.g., smartphone, laptop, other charging equipment) into the Type-C female port of the power meter.
- Power On: The device will automatically power on and display real-time measurements once connected.
5. Operating Instructions
5.1 Display Modes
The device supports multiple display pages to show various parameters. To switch between display pages, press the physical button on the side of the device once.
5.2 Screen Rotation
To rotate the screen display direction, double-tap the physical button. This feature is useful for adapting to different viewing angles and connection orientations.
5.3 Data Recording and Reset
The device intelligently records the highest power, voltage, and maximum current. It also supports data saving in case of power failure. To reset accumulated data (e.g., capacity, electricity, timing), typically a long press of the button is required, though specific instructions may vary slightly by model.
6. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Avoid using liquids or abrasive cleaners.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- Handling: Although the device features a durable CNC metal case, avoid dropping it or subjecting it to strong impacts to prevent damage to internal components or the display.
- Firmware: Check the manufacturer's website periodically for any available firmware updates to ensure optimal performance and compatibility.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Device not turning on | No power input; faulty connection; device malfunction. | Ensure the power source is active and the connection is secure. Try a different power source or cable. If the issue persists, contact support. |
| Inaccurate readings | Loose connection; incompatible device/charger; environmental factors. | Check all connections. Ensure the connected devices are within the meter's specified voltage/current range. Avoid extreme temperatures. |
| Screen not rotating | Incorrect button press; temporary software glitch. | Ensure you are double-tapping the button quickly. Try disconnecting and reconnecting the device. |
| Data not saving | Power interruption during recording; device malfunction. | Ensure stable power supply during critical measurements. If data loss occurs frequently, contact support. |
8. User Tips
- For the most accurate readings, ensure all connections are firm and stable.
- Utilize the screen rotation feature (double-tap button) to easily read the display regardless of the device's orientation.
- When testing fast charging, observe the power (W) and current (A) values to confirm the charger is delivering the expected performance.
- Take advantage of the data recording feature for long-term monitoring of charging cycles or battery degradation.
- Keep the device's Type-C ports clean to ensure good contact and prevent connection issues.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official Diymore website or contact your retailer. A detailed user manual in PDF format is also available for download from the seller's product page for further reference.
Note: This device is intended for DIY electrical testing and monitoring. Ensure you have adequate knowledge of electrical safety before use. The manufacturer is not responsible for any damage or injury caused by improper use.