1. Product Introduction
The HT-ED10AC20 is a 20-channel capacity testing and maintenance instrument designed for batteries with voltages ranging from 1 to 5V. It supports various battery chemistries including ternary lithium, lithium iron phosphate, lithium titanate, nickel-metal-hydride, and nickel-cadmium batteries. The device offers high precision with a current and voltage accuracy of ±1% and ±0.02V respectively. Key functions include battery capacity testing, balancing, pulse charging, and cycling. The accompanying software allows for control over battery working steps, ensuring high precision, strong timeliness, simple operation, and practical reliability. This instrument provides comprehensive battery testing and maintenance services for both battery manufacturers and end-users.
Each channel is equipped with a dedicated processor to ensure precise capacity calculation, timing, voltage, and current control. Multiple capacity testing methods are available to suit different scenarios. The upper computer software supports up to 9999 charge/discharge cycles. The device features full-channel isolation technology, allowing independent setting of charging and discharging parameters for each channel, or applying the same parameters across channels for balanced battery pack effects. It also supports group matching, where test results can be matched against custom standards. The device is compatible with various physical battery specifications, including 18650, 26650, pouch cells, and block cells.
The test status pane colors are customizable for easy visual inspection of device status during large-scale tests.
2. Specifications
2.1 General Specifications
- Brand Name: Heltecbms
- Origin: Mainland China
- Certification: CE
- DIY Supplies: Electrical
- Semi-finished product: No
- Battery Included: No
- High-concerned chemical: None
- Power Source: AC
2.2 Device Parameters
| Parameter | Value |
|---|---|
| Product Model | HT-ED10AC20 |
| Testing Voltage | Single Channel 1-5V |
| Number of Channels | 20 |
| Max Charging Current | 10A |
| Max Discharging Current | 10A |
| Input Power | Standby power: 80W, full-load power: 1500W |
| Measurement Voltage Accuracy | ±0.02V |
| Measurement Current Accuracy | ±0.02A |
| Measurement Battery Type | Lithium-ion battery |
| Voltage Balancing Function | Yes |
| Machine size | 63.5cm* 30cm*16cm |
| Inter-channel voltage resistance | AC1000V/2min, no abnormality |
2.3 Environmental Requirements
- Operating temperature: <35 °C
- Humidity: <90%
3. Setup Instructions
3.1 Unpacking and Inspection
Carefully unpack the device and verify all components are present according to the package list:
3.2 Physical Connections
- Connect the AC 220V power cord to the power input socket on the rear panel of the device.
- Connect the device to a computer using the provided data cable (USB or network cable, depending on model).
- Connect the battery fixture lines to the corresponding channels on the front panel of the device.
- Ensure the battery's electrode plates make full and good contact with the probe housing. The minimum height of the probe can be adjusted to 32mm and the maximum height to 130mm. Adjust the lower fixture height for different battery types (e.g., NiMH No. 5, 18650 lithium, 26650 lithium iron phosphate) using the scales on both sides.
- For series connections, ensure proper wiring as shown in the connection diagram.
3.3 Initial Power-On
- Turn on the main power switch on the rear panel.
- Observe the indicator lights on the front panel. After initialization, the device should enter a 'stop' state.
4. Operating Instructions
4.1 Software Installation and Connection
- Locate and open the installation software. It is recommended not to install on the C drive to avoid potential errors.
- After installation, launch the software. During the first run, ensure 'Public Network' is selected if prompted by the network firewall.
- Click the "Connect" button in the upper left corner of the interface. Then click "Search" to find the device's IP address. Select the device and click "Connect Device". An "IP Settings" window may appear; click "OK" to accept default settings.
Note: If the software encounters issues (e.g., errors with username/password, or constant 'Connecting...' status), try running it as an administrator, reinstalling on a different drive, disabling the public network firewall, or resetting firewall settings.
The device information, including connection status and channel numbers, will be displayed. Double-clicking a device will show detailed settings.
4.2 Setting Up Work Steps (Battery Capacity Detection Example)
- In the software, click the "Step" button in the upper left corner.
- Select the corresponding machine model (e.g., HT-ED10AC20) from the top left.
- Click "Add Workstep Program" in the bottom right to create a new plan. Enter a name (e.g., "Ternary Lithium Battery") and set the parallel number to 1. Confirm.
- Select the newly created plan. Click "Add" to add a step.
- For the first step, choose "CC&CV Charge" (Constant Current & Constant Voltage Charge). Set the charging voltage (e.g., 4200mV for ternary lithium) and charging current (e.g., 5000mA). Set the cut-off current (e.g., 300mA). Confirm.
- Add a second step: Choose "Idle". Set the idle time (e.g., 3 minutes). Confirm.
- Add a third step: Choose "CC Discharge" (Constant Current Discharge). Set the minimum discharge voltage (e.g., 2800mV for ternary lithium) and discharge current (e.g., 5000mA). Confirm.
- Add a fourth step: Choose "Idle". Set the idle time (e.g., 3 minutes). Confirm.
- Add a fifth step: Choose "CC&CV Charge". Set the charging voltage (e.g., 3700mV) and charging current (e.g., 5000mA). Set the cut-off current (e.g., 300mA). Confirm.
- Click "Save" to save the work steps.
4.3 Starting a Test
- Exit the work step settings. Right-click on the desired channel (e.g., channel 0-7-1) in the main interface.
- Select "Settings/Start".
- In the "Startup Params" window, select the work step plan you just created (e.g., "Ternary Lithium Battery"). Confirm.
- The device will begin the test automatically. The status of the channel will update, showing voltage, current, and capacity.
4.4 Data Analysis and Export
- To view detailed data for a specific battery channel, right-click on the channel and select "Analyze".
- A curve change diagram will appear, showing voltage, current, and capacity over time.
- To export data, click "Detail" then "Export detail data" in the Data Analysis window. Select the desired data points and confirm. Save the Excel file to your desktop.
4.5 Setting Up Work Steps (Battery Balancing Example)
- Click the "Step" button in the top left.
- Select your machine model in the top left.
- Click "Add Workstep Program" in the bottom right. Enter a name (e.g., "Charging Balancing") and set the parallel number to 1. Confirm.
- Select the newly created plan. Click "Add".
- Choose "CC&CV Charge". Set the voltage to the desired equalization voltage (e.g., 3700mV). Set the charging current (e.g., 10000mA) and cut-off current (e.g., 500mA). Confirm.
- Click "Save".
- To create a discharge equalization scheme, repeat steps 3-5, but choose "CC&CV Discharge" and set the discharge voltage (e.g., 3000mV) and discharge current (e.g., 5000mA), with a cut-off current of 500mA.
4.6 Starting a Balancing Test
- Right-click on the channel you want to balance. Select "Settings/Start".
- In the "Startup Params" window, select the appropriate balancing work step plan (e.g., "Charging Balancing" or "Discharge Balancing"). Confirm.
- The device will automatically begin the balancing process for the selected channel.
- To control multiple channels simultaneously, press Ctrl + A to select all channels, then right-click and select "Settings/Start" to apply the same work step plan.
5. Maintenance
- Maintain the ambient temperature and humidity within the specified range (<35 °C, <90% humidity) when using the equipment.
- Ensure the air inlet at the rear of the equipment is not blocked and has a ventilation space of more than 5CM.
- Keep the air outlets on both sides of the equipment clear to ensure a ventilation space of more than 5CM.
- Ensure the top air inlet and bottom air inlet are unobstructed and not blocked by debris.
- After each charge or discharge cycle, allow sufficient time for the battery to cool down.
6. Troubleshooting
6.1 Software and Connection Issues
- Installation on C drive causes errors: Run the software as an administrator. If issues persist, reinstall on another drive.