1. Product Overview
Thank you for selecting the Y&H MPPT Solar Charge Controller. This device utilizes an advanced MPPT control algorithm to quickly track the maximum power point of your PV array, ensuring maximum energy harvest from solar panels and significantly improving solar system efficiency.
Key features include:
- Advanced MPPT Technology: Tracking efficiency no less than 99.5%, conversion efficiency up to 98%.
- Multi-Wave Peak Tracking: Accurate identification and tracking of maximum power points.
- Wide PV Array Voltage Range: Supports 12V/24V automatic voltage identification.
- Dynamic LCD Display: Shows operation data and working status.
- Versatile Load Control Modes: General, light control, dual time, pure charger, and timing modes.
- Battery Compatibility: Supports Seal, GEL, Flooded, LiFePO4, and Li(NiCoMn)O2 battery types.
- Temperature Compensation: Built-in function for battery charging.
- Power Statistics: Records power generation and consumption.
- Communication (Optional): RS485 interface for PC monitoring and external display units.

Highlights 100% MPPT technology, 99.5% tracking efficiency, 12V/24V AUTO compatibility, 98% conversion efficiency, PV/Voc 16V-75V input range, and easy mounting.
2. Components and Controls
Familiarize yourself with the various ports and buttons on your MPPT solar charge controller.

This diagram labels the key components of the controller.
- LCD: Liquid Crystal Display for operational data and status.
- Set Button: Used to switch load in manual mode, or to adjust parameters.
- USB Output: Provides 5V power for charging devices.
- Menu Button: Used to browse interfaces and enter/save settings.
- Battery Terminal: Connects to the battery bank (+ and -).
- Photovoltaic Array Terminals: Connects to the solar panels (+ and -).
- USB Output: Additional 5V USB output.
- Temperature Sensor Interface (Optional): For external temperature sensor. If not connected, the controller compensates charging parameters at 25°C.
3. Setup and Installation
3.1. Installation Precautions
- Install the controller in a well-ventilated area, away from direct sunlight and high temperatures. Avoid locations where water can enter.
- Use appropriate screws (M4 or M5, cap diameter <10mm) to fix the controller to a wall or platform.
- Ensure sufficient space around the controller for cooling and cable connections.
- Mounting hole distance: 128.8mm x 100mm, hole diameter: 4mm.
- Always connect components to the charge controller in the specified sequence. Pay close attention to positive (+) and negative (-) polarities.
- Do NOT insert fuses or turn on circuit breakers during installation.
- When disconnecting the system, reverse the connection order.
- Always connect the battery first to allow the controller to recognize the system voltage.
- Install the battery fuse as close to the battery as possible (within 150mm of the battery group).
- For positive grounding controllers, any positive connection of solar load or battery can be grounded.
- All terminals are tightened at the factory; loosen them before making connections.
- Do not change the connection sequence, as this may cause system voltage recognition faults.
- Keep battery-to-controller cable length as short as possible (30cm to 100cm).
- Short circuits at controller terminals can cause fire or explosion. Use a fuse at the battery side (1.5 times rated current of controller).
- If the battery is connected in reverse, do not connect any load; otherwise, the load and controller may be destroyed.
- Solar panel voltage can be high; ensure PV max is within the safety MPPT range to prevent injury or damage.
- Before connecting a load, close the controller's output with the button. The controller does not offer reverse connection protection for loads.
3.2. Wiring Diagram and Connection Order

Illustrates wiring for both 12V and 24V systems, showing connections for solar panels, battery, and load.
Connection Order:
- Connect the Battery: Install a fuse at the battery terminal (distance <50mm).
- Connect the Load: Ensure the load is within the controller's specifications.
- Connect the PV Array: Connect your solar panels to the PV terminals.
- Controller Power-On: After connecting the battery, the controller will power on, identify the system voltage, and the display screen should light up. If not, refer to the troubleshooting section.
Important Notices:
- This MPPT series is a common positive controller. The positive poles of the PV array, battery, and load can be grounded simultaneously.
- If an inverter or other high starting current device is used, connect it directly to the battery, NOT to the controller's load terminal.
4. Operating Instructions
4.1. Button Functions
| Mode/Function | Remarks |
|---|---|
| Load Switch | In manual load mode, short press the SET button to switch the load ON/OFF. |
| Breakdown | Short press the SET button. |
| Browse Mode | Short press the MENU or SET button to cycle through display screens. |
| Set Mode | Long press MENU to enter secondary browsing. Long press MENU again to enter set mode. Short press MENU/SET to adjust parameters. Long press MENU to save. 20s inactivity or long press SET exits without saving. |
4.2. LCD Display Indicators
The LCD dynamically displays various parameters and statuses:
- Night Display: Solar panel input voltage below sensor identification point.
- Daytime Display: Solar panel input voltage above sensor identification point.
- PV Array Parameter: Displays solar panel data (e.g., voltage).
- Battery Parameter: Displays battery data (e.g., voltage, temperature).
- Load Parameter: Displays load status.
- System Voltage: Controller automatically adjusts data based on detected system voltage.
- Numerical Display Area: Shows values for parameters.
- Timer Setting Function: Indicates timer settings.
- Switch Graphic Symbol: Indicates active function.
- Unit Symbol Value: Displays units (V, A, °C, Ah).
- Warning: Lights up when a fault occurs.
- Load Status: Indicates Load ON/OFF.
- Output Power: Lights up when load terminal has output.
- Battery Capacity: Strip-type indicator shows battery charge level.
- Charge Status: Lights up when charging, flashes during float charge, no display when not charging.
4.3. Operation Steps
- Initialization: After power-on, the controller displays an initialization screen for 1 second, then enters the main interface.
- Auto-Switch Display: If no operation for 20s on the main interface, it automatically cycles through battery voltage, solar panel voltage, and ambient temperature (3s each). Long press SET for >5s to speed up auto-exchange; release to stop. Solar panel voltage is not displayed at night.
- Load Control: Press SET on the main interface to turn the load ON or OFF.
- Menu Navigation: Press MENU to cycle through different menu screens:
- Main Interface
- Total Charge Power (AH)
- Total Discharge Power (AH)
- Load Disconnect Voltage (LVD)
- Load Reconnect Voltage (LVR)
- Float Voltage (HVD)
- Load Timing Mode
- Battery Mode
- System Voltage Select
4.4. Parameter Settings
To adjust parameters like Float Voltage, Load Working Mode, and System Voltage Select:
- Navigate to the desired parameter screen using the MENU button.
- Enter Set Mode: Long press the MENU button for more than 5 seconds until the parameter value flashes.
- Adjust Value: Short press MENU to increase the value, short press SET to decrease the value.
- Save Settings: Long press the MENU button for more than 5 seconds again to save the new value and exit set mode.
- Exit Without Saving: If no operation is performed for 20 seconds in set mode, the controller will automatically exit without saving changes.
Specific Parameter Explanations:
- Float Voltage (HVD): This is the high voltage disconnection point. The controller starts PWM function at this point to limit voltage rise.
- Low Voltage Reconnect Voltage (LVR): When battery voltage is low, the controller stops powering the load. Output reconnects when battery voltage exceeds LVR or by pressing SET.
- Low Voltage Disconnect Voltage (LVD): When battery voltage drops below LVD, load output is cut off and locked. Battery must be charged until voltage is above LVD, or SET button is pressed to release.
- Load Working Mode Selection: Default is 24 hours. If set to <23 hours, load starts at sunset and works for the set duration or until sunrise.
- System Voltage Select: Default is