PowMr POW-6.2KP

Contents

PowMr 6200W Solar Hybrid Inverter User Manual

Model: POW-6.2KP

1. Introduction

This PowMr 6200W Solar Hybrid Inverter is a multi-function inverter/charger, combining the functionalities of an inverter, MPPT solar charger, and battery charger. It is designed to provide uninterruptible power support in a compact size. The comprehensive LCD display allows for user-configurable and easily accessible button operation to adjust settings such as battery charging current, AC/solar charger priority, and acceptable input voltage based on various applications.

Key Features

  • Pure sine wave inverter output.
  • Inverter operation without battery.
  • Built-in MPPT solar charge controller.
  • Configurable input voltage range for home appliances and personal computers via LCD setting.
  • Configurable battery charging current based on applications via LCD setting.
  • Configurable AC/Solar Charger priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart function when AC power recovers.
  • Overload, over temperature, and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.

Basic System Architecture

The inverter/charger can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners. It supports solar and bypass power supply, solar and grid charging, and keeps your battery safely charged as backup.

Application Range of PowMr Solar Hybrid Inverter
Figure 1: Application Range of the PowMr Solar Hybrid Inverter, including Outdoors, Household, Photovoltaic Rooftop, RV, Yacht, Commercial Electricity, Camping, Emergency Electricity, Solar Light, and Agricultural Electricity.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow the required specifications to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  10. A fuse is provided as over-current protection for the battery supply.
  11. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  12. NEVER cause AC output and DC input short circuits. Do NOT connect to the mains when DC input short circuits.
  13. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Package Contents

Upon unpacking, please ensure all items listed below are present and undamaged. If any items are missing or damaged, please contact your dealer.

  • 1x PowMr Hybrid Solar Inverter (Model POW-6.2KP)
  • 1x Parallel Communication Cable
  • 1x Current Sharing Cable
  • 2x Expansion Screws
  • 1x Battery Fuse
  • 1x User Manual (this document)
Video 1: Unboxing the PowMr 6200W Solar Hybrid Inverter and its included accessories.
Contents of the PowMr Solar Hybrid Inverter package
Figure 2: Visual representation of the package contents, including the inverter, cables, screws, and user manual.

4. Installation

4.1 Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the items listed in the "Package Contents" section.

4.2 Preparation

Before connecting any wirings, please remove the bottom cover of the inverter by unscrewing two screws.

4.3 Mounting the Unit

Consider the following points before selecting where to install the inverter:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to allow the LCD display to be read at all times.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Ensure sufficient heat dissipation by keeping other objects and surfaces clear, as shown in the diagram below.

Note: Suitable for mounting on concrete or other non-combustible surfaces only.

Mounting dimensions and clearances for PowMr Solar Hybrid Inverter
Figure 3: Recommended mounting clearances (20cm side, 50cm top/bottom) for proper air circulation.

Install the unit by screwing three screws. It's recommended to use M4 or M5 screws.

4.4 Battery Connection

CAUTION: For safety and regulation compliance, it's required to install a separate DC over-current protector or disconnect device between the battery and inverter. Please refer to the typical amperage in the specifications table for the required fuse or breaker size.

WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce the risk of injury, use the proper recommended cable size, stripping length, and tinning length as specified in the full user manual (PDF).

Battery connection diagram for PowMr Solar Hybrid Inverter
Figure 4: Diagram showing battery connection terminals and recommended cable preparation.

Follow these steps for battery connection:

  1. Prepare positive and negative cables based on recommended terminal size.
  2. Connect all battery packs as required.
  3. Insert battery cables flatly into the battery connector of the inverter and ensure the bolts are tightened with a torque of 2-3Nm. Verify polarity at both the battery and the inverter/charger, and ensure battery cables are tightly screwed to the battery connector.

4.5 AC Input/Output Connection

CAUTION: Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and fully protected from overcurrent. The recommended AC breaker is 50A.

CAUTION: There are two terminal blocks with "IN" and "OUT" markings. Do NOT mis-connect input and output connectors.

WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce the risk of injury, use the proper recommended cable size as specified in the full user manual (PDF).

WARNING: Be sure that the AC power source is disconnected before attempting to hardwire it to the unit.

Follow these steps for AC input/output connection:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Ensure the PE protective conductor is connected first.
  4. Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws. Ensure the PE protective conductor is connected first.
  5. Make sure the wires are securely connected.

CAUTION: Important: Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuiting when these inverters are operated in parallel.

CAUTION: Appliances such as air conditioners require at least 2-3 minutes to restart to balance refrigerant gas. If a power shortage occurs and recovers quickly, it can damage connected appliances. Check if your air conditioner has a time-delay function before installation.

4.6 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING: All wiring must be performed by qualified personnel. It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce the risk of injury, use the proper recommended cable size as specified in the full user manual (PDF).

Follow these steps to implement PV module connection:

  1. Remove 10mm of insulation sleeve for positive and negative conductors.
  2. Check the correct polarity of the connection cable from PV modules and PV input connectors. Connect the positive pole (+) of the connection cable to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection cable to the negative pole (-) of the PV input connector.
  3. Make sure the wires are securely connected.

CAUTION: Each inverter should connect to PV modules separately.

4.7 Final Assembly

After connecting all wirings, replace the bottom cover by screwing the two screws back in place.

5. Operation

5.1 Power ON/OFF

Once the unit has been properly installed and the batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

5.2 Operation and Display Panel

The operation and display panel, located on the front of the inverter, includes three indicators, four function keys, and an LCD display. These elements provide information on the operating status and input/output power.

Front view of PowMr Solar Hybrid Inverter showing LCD display and control buttons
Figure 5: Front view of the inverter, highlighting the LCD display and control buttons.

LED Indicators

LED IndicatorColorStatusMessages
AC/INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

Function Keys

Function KeyDescription
ESCTo exit setting mode.
UPTo go to previous selection.
DOWNTo go to next selection.
ENTERTo confirm the selection in setting mode or enter setting mode.

5.3 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use the "UP" or "DOWN" buttons to select setting programs, then press "ENTER" to confirm or "ESC" to exit. The LCD display provides various configurable parameters, including:

  • Output Source Priority (Program 01): Configure whether solar, utility, or SBU (Solar-Battery-Utility) is the primary power source.
  • Maximum Charging Current (Program 02): Set the total charging current for solar and utility chargers.
  • AC Input Voltage Range (Program 03): Select between appliance mode (90-280VAC) or UPS mode (170-280VAC).
  • Power Saving Mode (Program 04): Enable or disable power saving.
  • Battery Type (Program 05): Select between AGM, Flooded, or User-Defined.
  • Auto Restart (Program 06 & 07): Enable or disable auto restart after overload or over temperature.
  • Output Voltage (Program 08): Adjust AC output voltage (220V/230V/240V).
  • Output Frequency (Program 09): Set output frequency (50Hz/60Hz).
  • Auto Bypass (Program 10): Configure automatic bypass when mains power is normal.
  • Maximum Utility Charging Current (Program 11): Set the maximum current drawn from utility for charging.
  • Setting Voltage Point Back to Utility Source (Program 12): Define the battery voltage threshold for switching back to utility.
  • Battery Fully Charged Voltage (Program 13): Set the voltage at which the battery is considered fully charged.
  • Charger Source Priority (Program 16): Configure the priority for charging sources (Solar first, Utility first, Solar and Utility, Only Solar).
  • Buzzer Mode (Program 18): Configure when the buzzer sounds (mute, input source change, warning/fault).
  • Auto Return to Default Display Screen (Program 19): Set whether the display returns to default or stays on the last screen.
  • Backlight Control (Program 20): Turn backlight on or off.
  • Overload Bypass (Program 23): Enable or disable transfer to line mode on overload in battery mode.
  • Modbus ID Setting (Program 25): Set Modbus ID.
  • Bulk Charging Voltage (Program 26): Set the bulk charging voltage for user-defined battery types.
  • Floating Charging Voltage (Program 27): Set the floating charging voltage for user-defined battery types.
  • AC Output Mode (Program 28): Select between single phase or parallel operation.
  • Low DC Cut-off Voltage (Program 29): Set the low DC cut-off voltage.

For detailed explanations and specific values for each setting, please refer to the full user manual (PDF).

5.4 Operating Mode Description

The inverter operates in various modes depending on the power sources available and configured priorities. These modes include:

  • Standby Mode / Power Saving Mode: In standby, the inverter can charge the battery without AC output. In power saving mode, the output will be off if the connected load is very low.
  • Fault Mode: Indicates errors caused by internal circuit issues or external factors like over temperature or short circuits.
  • Line Mode: The unit provides output power from the mains and can charge the battery. Depending on settings, solar energy can also contribute to power loads and charge batteries.
  • Battery Mode: The unit provides output power from the battery and/or PV power.

The LCD display icons will change to reflect the current operating mode and charging status. For a complete overview of all display icons and their meanings, consult the full user manual (PDF).

6. Battery Equalization

Battery equalization is a function added to the charge controller to reverse the buildup of negative chemical effects like stratification and to remove sulfate crystals from battery plates. If left unchecked, these conditions can reduce overall battery capacity. Therefore, periodic battery equalization is recommended.

How to Apply Equalization Function

You must enable the battery equalization function in monitoring LCD setting program 33 first. Then, you can apply this function by either:

  1. Setting the equalization interval in program 37.
  2. Activating equalization immediately in program 39.

When to Equalize

In the float stage, when the set equalization interval (battery equalization cycle) is reached, or if equalization is actively initiated, the controller will begin the Equalize stage.

Equalize Charging Time and Timeout

During the Equalize stage, the controller will supply power to charge the battery until its voltage reaches the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery at this voltage. The battery will remain in the Equalize stage until the set battery equalized time is reached.

If the battery equalized time expires and the battery voltage has not risen to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery equalized voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.

7. Setting for Lithium Battery

7.1 Lithium Battery Connection

If using a lithium battery with the inverter, only configured lithium batteries are supported. There are two connectors on the lithium battery: the RS485 port of the BMS and the power cable.

Follow these steps to implement lithium battery connection:

  1. Assemble the battery terminal based on the recommended battery cable and terminal size (similar to lead-acid batteries).
  2. Connect the end of the RS485 port of the battery to the BMS (RS485) communication port of the inverter.
BMS Intelligent Communication Upgrade for PowMr Solar Hybrid Inverter
Figure 6: The inverter obtains real-time State of Charge (SOC) data from the lithium battery system, enabling intelligent energy management.
Multiple Communication Interfaces on PowMr Solar Hybrid Inverter
Figure 7: The inverter features RS232 for host communication and integrated RS485/BMS for lithium battery systems.

7.2 Lithium Battery Communication and Setting

If using a lithium battery, ensure the BMS communication cable is connected between the battery and the inverter. This cable transmits information and signals, allowing for:

  • Re-configuring charging voltage, charging current, and battery discharge cut-off voltage according to lithium battery parameters.
  • The inverter to start or stop charging based on the lithium battery's status.

Make sure the lithium battery RS485 port connects to the inverter using a Pin-to-Pin connection. The communication cable is included in the package.

Setting for PYLON US2000 Lithium Battery

For PYLONTECH US2000 lithium batteries, use the dip switches to set the baud rate and battery group address. Dip switch 1 "ON" represents a baud rate of 9600. Dip switches 2, 3, and 4 are reserved for battery group address. Set dip switches 2, 3, and 4 on the master battery to configure the group address.

NOTE: "1" is the upper position and "0" is the bottom position.

7.3 Setting for Lithium Battery Without Communication

If communication is not established, follow these settings to avoid lithium battery BMS protection:

  1. Obtain the battery BMS specifications (Max charging voltage, Max charging current, Discharging protection voltage).
  2. Set battery type to "USE" (user-defined) in LCD program 05.
  3. Set C.V voltage as Max charging voltage of BMS - 0.5V.
  4. Set floating charging voltage as C.V voltage.
  5. Set Low DC cut-off voltage as discharging protection voltage of BMS + 2V.
  6. Set Max charging current to be less than the Max charging current of BMS.
  7. Set voltage point back to utility source (Program 12) as Low DC cut-off voltage + 1V.

Remark: It is recommended to finish settings without turning on the inverter (just let the LCD show, no output). After finishing settings, restart the inverter.

8. Specifications

The PowMr 6200W Solar Hybrid Inverter (Model POW-6.2KP) offers robust performance for various solar energy needs. Below are the detailed specifications:

8.1 General Specifications

AttributeValue
Model NumberPOW-6.2KP
Item6.2KW hybrid inverter
TypeDC/AC Inverters
Brand NamePowMr
OriginMainland China
CertificationCE
Operating Temperature Range-10°C to 55°C
Storage Temperature-15°C to 60°C
Humidity20%~95% Relative Humidity (Non-condensing)
Noise≤50db
Dimensions (D*W*H)450x300x130 mm
Net Weight9.6 kg
Hign-concerned ChemicalNone

8.2 Line Mode Specifications

AttributeValue
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage (UPS)170Vac±7V
Low Loss Voltage (Appliances)90Vac±7V
Low Loss Return Voltage (UPS)180Vac±7V
Low Loss Return Voltage (Appliances)100Vac±7V
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionLine mode: Circuit Breaker; Battery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time (UPS)10ms typical
Transfer Time (Appliances)20ms typical

8.3 Inverter Mode Specifications

AttributeValue
Rated Output Power6.2KVA/6.2KW
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency60Hz or 50Hz
Peak Efficiency94%
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage48Vdc
Cold Start Voltage46.0Vdc
Low DC Warning Voltage (@load < 20%)44.0Vdc
Low DC Warning Voltage (@ 20% ≤ load < 50%)42.8Vdc
Low DC Warning Voltage (@load ≥ 50%)40.4Vdc
Low DC Warning Return Voltage (@load < 20%)46.0Vdc
Low DC Warning Return Voltage (@ 20% ≤ load < 50%)44.8Vdc
Low DC Warning Return Voltage (@load ≥ 50%)42.4Vdc
Low DC Cut-off Voltage (@load < 20%)42.0Vdc
Low DC Cut-off Voltage (@ 20% ≤ load < 50%)40.8Vdc
Low DC Cut-off Voltage (@load ≥ 50%)38.4Vdc

8.4 Charge Mode Specifications

AttributeValue
Max Charging Current (PV+AC)120Amp (@ VI/P=230Vac)
Max Charging Current (AC)100A (@ VI/P=230Vac)
Bulk Charging Voltage (Flooded Battery)58.4Vdc
Bulk Charging Voltage (AGM / Gel Battery)56.4Vdc
Float Charging Voltage54Vdc
Overcharge Protection63Vdc
Charging Algorithm3-Step
Rated Power (Solar Input)6500W
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range60Vdc~500Vdc
Max. Input Current (PV)27A
Max Charging Current (PV)120A

For detailed PV module selection and configuration, refer to the full user manual (PDF).

9. Troubleshooting

This section provides solutions to common issues you might encounter with your PowMr Solar Hybrid Inverter. For more detailed troubleshooting steps and fault codes, please refer to the full user manual (PDF).

9.1 Fault Reference Code

Fault CodeFault EventIcon on Display
01Over temperature of inverter module01 ERROR
02Over temperature of DCDC module02 ERROR
03Battery voltage is too high03
04Over temperature of PV module04
05Output short circuited.05
06Output voltage is too high.06 ERROR
07Overload time out07 ERROR
08Bus voltage is too high08 ERROR
09Bus soft start failed09 ERROR
10PV over current10
11PV over voltage11
12DCDC over current12
13Over current or surge13 ERROR
14Bus voltage is too low14 ERROR
15Inverter failed (Self-checking)15
16Over DC voltage in AC output16 ERROR
17Reserved
18Op current offset is too high18 ERROR
19Inverter current offset is too high19 ERROR
20DC/DC current offset is too high20
21PV current offset is too high21 ERROR
22Output voltage is too low22 ERROR
23Inverter negative power23 ERROR

9.2 Warning Indicator

Warning CodeWarning EventAudible AlarmIcon Flashing
02Temperature is too HighBeep three times every second02
04Low batteryBeep once every second04
07OverloadBeep once every 0.5 second07 OVER LOAD
10Output power deratingBeep twice every 3 seconds10
15PV energy is lowBeep twice every 3 seconds15
19Lithium Battery communication is failedBeep once every 0.5 second19
20Battery low and it isn't up to the setting value of program 13Beep twice every 3 seconds20
E9Battery equalizationNoneE9
bPBattery is not connectedNonebP

9.3 General Troubleshooting

ProblemExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.The battery voltage is too low.1. Re-charge battery. 2. Replace battery.
No response after power on.1. Battery voltage is too low. 2. Battery polarity is connected reversed. 3. Input protector is tripped.1. Check if batteries and wiring are connected well. 2. Re-charge battery. 3. Replace battery. 4. Check if AC breaker is tripped and AC wiring is connected well.
Mains exist but the unit works in battery mode.1. Insufficient quality of AC power. 2. "Solar First" is set as priority.1. Check if AC wires are too thin/long. 2. Check generator (if applied) or input voltage range setting. 3. Change output source priority to Utility first.
When the unit is turned on, internal relay is switched on and off repeatedly.Battery is disconnected.Check if battery wires are connected well.
Buzzer beeps continuously and red LED is on.Overload error, Output short circuited, Over temperature, Battery over-charged, Battery voltage too high, Output abnormal.Reduce connected load, check wiring, ensure air flow, return to repair center, check battery specs.

10. User Tips

  • Parallel Operation: When connecting multiple inverters in parallel, ensure all battery cables are of the same length and material type to prevent voltage differences and ensure proper operation.
  • Lithium Battery Setup: If using lithium batteries, carefully follow the specific connection and LCD setting procedures for BMS communication or non-communication setups to ensure optimal performance and battery protection.
  • Overload Protection: Be mindful of the inverter's output capacity. If an overload occurs, reduce the connected load immediately to prevent damage to the inverter and connected appliances.
  • Professional Installation: For complex wiring or if you are unsure about any installation steps, always consult with qualified personnel to ensure safety and correct setup.
  • Firmware Updates: Keep your inverter's firmware updated to the latest version for optimal performance and to resolve potential issues. If problems persist after updates, contact customer support.

11. Warranty and Support

11.1 Warranty

This PowMr Solar Hybrid Inverter comes with a 12-month warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage caused by improper installation, misuse, accidents, or unauthorized modifications.

If the product is damaged, please contact customer support for assistance. Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting guide, please send this inverter/charger back to a local dealer or service center for maintenance.

11.2 Contact Information

For technical support, warranty claims, or any inquiries regarding your PowMr Solar Hybrid Inverter, please contact us using the information below:

You can also refer to the full user manual (PDF) for additional information: View User Manual (PDF)

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.