1. Overview
The AISET temperature controller, developed and produced by Shanghai Yatai Instrument Co., Ltd., is an intelligent digital temperature control product designed for reliability, practicality, and cost-effectiveness. It covers multiple core series (NE, NGG, YLE) and various models, addressing diverse industrial and commercial temperature control needs, from basic entry-level control to high-precision, intelligent remote control.
Key Product Advantages:
- High control precision (±0.3~±1℃).
- Multiple output modes: relay, 4~20mA, 0~10V, SSR drive.
- Standard installation sizes: 48×48mm, 48×96mm, 72×72mm, 96×96mm.
- Functions include temperature correction, power-off memory, child lock, and timing setting.
- Flame-retardant ABS shell and anti-interference design.
- Fully compliant with EU safety and environmental protection standards (EMC 2014/30/EU, LVD 2014/35/EU, RoHS 2011/65/EU, WEEE 2012/19/EC).

2. Important Safety Warnings
Read carefully before use to avoid injury, equipment damage, or non-compliance with regulations.
- Industrial/Commercial Use: This product is for industrial and commercial use only, not for household use. Keep out of reach of children and untrained personnel.
- Electrical Safety: Turn off power before wiring, maintenance, disassembly, or cleaning. Confirm power supply voltage matches the rated voltage (AC 187~244V, 50/60Hz), with voltage deviation ≤ ±10% to prevent component burnout.
- Rated Parameters: Do not exceed rated parameters (voltage, load, temperature). Rated output load: up to 10A/250V AC (resistive load).
- Installation Environment: Install in a dry, ventilated environment, away from flammable, explosive, humid, or corrosive areas. Ambient temperature: -10~55°C (universal/intelligent), -30~80°C (precision/high-end); humidity ≤90% (non-condensing).
- Grounding: Mandatory grounding (IEC 60417-5019 symbol) is required to comply with EU standards and prevent electric shock.
- Modifications: Do not modify, disassemble, or repair without authorization. Unauthorized operation voids the warranty and may damage internal components.
- Abnormal Operation: Stop use and cut power if abnormal operation occurs (display failure, temperature deviation, sensor error). Sensor faults show "00", "98", "OPE" (open), or "SHr" (short); other faults show alarm code "Axx".
- Disposal: Dispose of the product according to EU WEEE 2012/19/EC directives. Comply with RoHS 2011/65/EU regarding harmful substances.
- Radio Interference: This is a Class A product and may cause radio interference in domestic environments. Take measures to reduce interference.
3. Key Specifications
| Item | Parameter |
|---|---|
| Operating Voltage | AC 187~244V, 50/60Hz (universal for all models) |
| Power (W) | 72W |
| Weight | Approx. 0.1~0.13kg |
| Control Accuracy | ±0.3~±1°C; temperature correction range -9~9°C |
| Control Range | 0~200°C (universal); 0~400°C (intelligent); -50~300°C (precision/high-end) |
| Input Signal | NTC sensor (universal/intelligent); Pt100/RTD optional (precision/high-end); internal/external sensor optional |
| Output Load | Up to 10A/250V AC (resistive load); output modes: relay, DC 4~20mA, 0~10V, SSR drive |
| Installation Type & Size | Panel installation (most models) or DIN rail installation (high-end models); sizes: 48×48mm, 48×96mm, 72×72mm, 96×96mm |
| Ambient Temperature | -10~55°C (universal/intelligent); -30~80°C (precision/high-end) |
| Ambient Humidity | ≤90% (non-condensing) |
| Is Smart Device | No |

4. Setup: Wiring Instructions
Always turn off power before wiring to avoid electric shock.
Refer to the product label for specific models and comply with IEC 60335-1:2020.
- Power Terminal (L/N): Connect to AC 187~244V. Ensure stable power supply. Terminals are marked with voltage parameters.
- Input Terminal (IN): Connect to NTC/Pt100/RTD sensor. Keep sensor wiring away from power cables to avoid interference.
- Output Terminal (OUT1/OUT2): Connect to the load (heater, cooler, SSR). Match the load type with the output mode. Terminals are clearly marked.
- Ground Terminal (PE): Mandatory grounding is required to comply with EU standards and prevent electric shock.
- Communication Terminal (high-end models): Connect RS-485 cable (A/B) to an upper computer for remote control.
⚠ WARNING: Incorrect wiring (e.g., no grounding, wrong voltage/sensor connection) can cause electric shock, fire, or damage, and violates EU regulations. Double-check all wiring before powering on. Use standard materials and ensure firm connections to prevent overheating. Full-load operation is recommended below 2500m altitude; for altitudes above 2500m, the load should be ≤80% of the rated capacity.

5. Basic Operation
5.1 Power On
After connecting power according to the wiring diagram and confirming grounding, turn on the power switch. The controller will automatically enter its working state. The digital display will show the measured temperature (PV) and the target temperature (SV). LED indicators will show heating, cooling, alarm, or communication status.
5.2 Temperature Setting & Key Functions
- Basic Temperature Setting: Press and hold "S" (SET) for 2 seconds until the display flashes. Adjust the target temperature using the "▲" (up) / "▽" (down) buttons. Hold for 1 second for quick adjustment. Press "S" to confirm, or "M" (MODE) to cancel.
- Temperature Correction: Long press "M" for 5 seconds (enter password if set). Find the correction parameter (H1/F19) and adjust it (-9~9°C) with "▲"/"▽". Press "S" to confirm.
- Child Lock: Long press the power key for 6 seconds to lock/unlock the device, preventing misoperation.
- Mode Switching: For precision/high-end models, enter advanced settings to set heating/cooling mode (COOL/HEAT). High-end models can switch between local and remote control via the "REM" key.
- Time Setting (Manual Mode): Press "S" to switch to time display. Long press "S" to adjust hour/minute with "▲"/"▽". Press "S" to confirm.
- Communication Setting (High-End Models): Connect the RS-485 cable to A/B terminals. Set the baud rate (9600/19200 bps) and address (1~247) to match the upper computer for remote control.
5.3 Display & Alarm Introduction
- Normal Mode: PV = measured temperature, SV = target temperature. LED indicators clearly show the working status.
- Setting Mode: A flashing display indicates a parameter is being set (temperature, correction, timing, etc.), with clear prompts.
- Alarm Mode: The alarm indicator lights up for over-temperature, sensor fault, or load abnormality.
- Sensor faults: "00", "98", "OPE" (open), or "SHr" (short).
- Other faults: Alarm code "Axx".
- Communication failure (high-end models): "Err".
6. Maintenance
- Installation Environment: Install in a dry, ventilated place, away from high temperatures, humidity, interference, and flammables. Ensure firm installation, preferably at a height of 1.4m. Avoid cold/heat sources or direct sunlight.
- Regular Checks: Regularly check wiring, sensor connections, and overall status.
- Cleaning: Clean the display and panel with a dry, soft cloth. Do not use corrosive cleaners. Ensure CE/RoHS marks remain clear.
- Calibration: Calibrate the device using the temperature correction function as needed.
- Protection: Prevent water or metal particles from entering the controller.
- Documentation: Retain the EU Declaration of Conformity and technical documents for 10 years for supervision purposes.
⚠ CAUTION: For faults, cut power and contact professional maintenance. Do not attempt to repair the device yourself. Use only AISET-approved accessories and do not modify internal parameters.
7. Troubleshooting
If the device exhibits abnormal behavior, refer to the following common issues and their indicators:
- Sensor Faults: The display may show "00", "98", "OPE" (indicating an open circuit in the sensor), or "SHr" (indicating a short circuit in the sensor).
- Other Faults: The display may show an alarm code "Axx".
- Communication Failure (High-End Models): The display may show "Err".
In case of any of these indications, stop use, cut power, and consult the full-version manual or contact professional maintenance.
8. User Tips
While no specific user tips were available from reviews or Q&A, general best practices for temperature controllers include:
- Always ensure proper ventilation around the unit to prevent overheating and ensure accurate readings.
- Periodically verify the accuracy of the temperature readings against a known standard, especially in critical applications.
- Keep the control panel clean and free from dust and debris to ensure button responsiveness and display visibility.
9. Warranty and Support
Warranty Period: 12-month warranty from the delivery date.
Coverage: Free repair or replacement for material or workmanship defects under normal use, in compliance with the manual and EU regulations.
Exclusions: The warranty does not cover damage resulting from improper operation, incorrect wiring, unauthorized disassembly, non-compliance with regulations, external factors, or normal wear and tear. Sensors and communication modules are considered vulnerable parts and are not covered.
Manufacturer: AISET (Shanghai Yatai Instrument Co., Ltd., China)
EU Compliance: This product meets EU EMC 2014/30/EU, LVD 2014/35/EU, RoHS 2011/65/EU, and WEEE 2012/19/EC directives, with CE certification.
Further Information: This document is a simplified EU compliance manual. For detailed model-specific operations and comprehensive information, please refer to the full-version user manual (PDF).
A comprehensive user manual in PDF format can be found here: AISET Temperature Controller User Manual (PDF)