1. Introduction and Product Overview
The PowMr POW-SunSmart SP5K is an all-in-one hybrid solar charge inverter designed for solar energy storage and AC sine wave output. It features DSP control and an advanced control algorithm, ensuring high response speed, reliability, and industrial standard performance. This inverter supports both single-phase and split-phase applications.
It supports 110V or 120V AC output with a maximum output power of 5000W. When paralleled, it can achieve a maximum combined AC output of 30KW with up to 6 units. The inverter has a wide PV input voltage range of 120-500V, and a single unit can accommodate a maximum 5500W PV array.
Key features include power-saving mode, time-of-use charging and discharging functions for optimized energy management, built-in lithium battery activation, and multiple targeted protection mechanisms to ensure stable and secure operation of your solar system.

2. Features
- Support for inverter and mains power hybrid output, including operation without a battery.
- Two output modes: mains bypass and inverter output for uninterrupted power supply.
- Four charging modes: Only Solar, Mains Priority, Solar Priority, and Mains & Solar hybrid charging.
- Advanced MPPT technology with an efficiency of 99.9%.
- LCD screen and 3 LED indicators for dynamic display of system data and operating status.
- Time slot control for prioritizing mains and battery usage based on local peak and valley tariffs.
- Power saving mode to reduce no-load loss.
- Intelligent variable speed fan for efficient heat dissipation and extended system life.
- Lithium battery activation by PV solar or mains, compatible with lead-acid and lithium batteries.
- 360° all-around protection including short circuit, over/under voltage, overload, and reverse protection.
3. Package Contents
Upon opening the packaging of your POW-SunSmart SP5K, you should find the following items:
- 1 x Hybrid Solar Inverter (POW-SunSmart SP5K)
- 1 x User Manual
- 1 x Warranty Card
- 2 x Terminals
- 8 x Screws
- 1 x Current Equalizer
- 1 x Parallel Cable
4. Important Safety Instructions
WARNING: Read all instructions and cautions in this manual carefully before beginning installation or operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Non-safety voltage exists inside the inverter. Do not disassemble the unit yourself. Contact professional maintenance personnel for repairs.
- Do not place the inverter within reach of children.
- Do not install the inverter in harsh environments (moist, oily, flammable, explosive, or heavily dusty areas).
- The mains input and AC output are high voltage; do not touch wiring terminals.
- The inverter housing can become hot during operation. Avoid touching it.
- Do not open the terminal protective cover when the inverter is operating.
- Install a proper fuse or circuit breaker externally for the solar charge inverter.
- Always disconnect the fuse or circuit breaker near the PV array, mains, and battery terminals before installing or adjusting wiring.
- After installation, ensure all wire connections are tight to prevent heat accumulation from poor connection.
- The all-in-one solar charge inverter is off-grid. It must be the only input device for the load. Do not use it in parallel with other input AC power to avoid damage.
- When installing a lead-acid liquid battery, wear safety goggles. Rinse with clean water immediately if battery acid contacts skin.
- Do not place metal objects near the battery to prevent short-circuits.
- Ensure good ventilation as acid gas may be generated when the battery is charged.
- Do not install the inverter and lead-acid battery in the same confined space to avoid corrosion from acid gas.
- Only batteries meeting the unit's requirements can be charged.
- Poorly connected or corroded wires can cause excessive heat, melting insulation, burning materials, and fire. Ensure connectors are tightened and wires secured.
- System connection wires should have a current density of not more than 5A/mm².
- Avoid direct sunlight and rainwater infiltration for outdoor installations.
- Even after power-off, high voltage may remain inside. Do not open or touch internal components until capacitors are fully discharged.
- Do not reverse battery input polarity, as this may damage the device.
- Do not touch the fan when it is working to prevent injury.
5. Installation Instructions
5.1 Select the Mount Location
Determine the installation position on a wall surface. Ensure sufficient airflow through the heat sink. Leave at least 200mm space to the left and right air outlets for natural convection heat dissipation.

5.2 Preparation
Before connecting any wiring, please remove the bottom cover of the inverter.
5.3 Wiring Specifications and Circuit Breaker Selection
Wiring and installation must comply with national and local electrical codes. The wiring diameter is for reference only. If the distance between the PV array, inverter, or battery is long, use thicker wires to reduce voltage drop.
| Models | Recommended PV wiring diameter | Maximum PV input current | Recommended circuit breaker type |
|---|---|---|---|
| POW-SunSmart SP5K | 6mm²/10AWG | 22A | 2P-25A |
Note: The voltage in series shall not exceed the maximum PV input open circuit voltage.
| Models | Recommended AC input wiring diameter | Maximum bypass input current | Recommended circuit breaker type |
|---|---|---|---|
| POW-SunSmart SP5K | 10mm²/7AWG | 63A | 2P-63A |
Note: An appropriate circuit breaker is already present at the Mains input wiring terminal; no additional one is needed.
| Models | Recommended battery wiring diameter | Rated battery discharge | Maximum charge current | Recommended circuit breaker type |
|---|---|---|---|---|
| POW-SunSmart SP5K | 30mm²/2AWG | 125A | 100A | 2P-200A |
| Models | Recommended AC output wiring | Rated inverter AC output current | Maximum bypass output current | Recommended circuit breaker type |
|---|---|---|---|---|
| POW-SunSmart SP5K | 10mm²/7AWG | 42A | 63A | 2P-63A |
5.4 AC Input/Output Wiring
- Before wiring, open the external circuit breaker and confirm the wire thickness.
- Connect the AC input wire according to the wire sequence and terminal position. Connect the ground wire first, then the live wire, and finally the neutral wire.
- Connect the AC output wire similarly. The ground wire should be connected to the grounding screw hole on the cabinet via an O-type terminal (recommended inner diameter 6mm).
5.5 PV Input Wiring
- Before wiring, disconnect the external circuit breaker and confirm wire thickness.
- Connect the PV input wire according to the wire sequence and terminal position. For parallel connections, different inverters need to be connected to different PV arrays or sources.
5.6 Battery Wiring
- Before wiring, disconnect the external circuit breaker and confirm wire thickness. The BAT wire should be connected via an O-type terminal (recommended inner diameter 6mm) to ensure a firm connection and prevent excessive heat.
- Connect the BAT wire according to the wire sequence and terminal position.
WARNING: Mains input, AC output, and PV array generate high voltage. Ensure circuit breakers or fuses are open before wiring. Be careful during wiring; do not close circuit breakers/fuses. Ensure '+' and '-' poles are connected correctly. A circuit breaker must be installed at the battery terminal. Disconnect the circuit breaker before wiring to prevent strong electric sparks and battery short circuits. If the inverter is used in a lightning-prone area, install an external lightning arrester at the PV input terminal.
5.7 Final Assembly and Startup
- Check all wiring for correctness and firmness, especially battery and PV input polarity, and AC input connection. Install the terminals cover.
- Close the circuit breaker at the battery terminal.
- Turn the rocker switch on the left side of the machine to the "ON" state. The "AC/INV" indicator flashing indicates normal inverter operation.
- Close the circuit breakers of the PV array and the Mains.
- Turn on AC loads one by one. Start with loads having a large surge current, then smaller ones, to avoid protection actions from simultaneous large current shocks.
Note: If the inverter does not work properly or the LCD/indicator is abnormal, refer to the Troubleshooting section.
6. Operating Modes
6.1 Charging Modes
The inverter offers four charging modes:
- Solar First: Prioritizes PV charging. Mains charging starts only if PV fails. Ideal for stable grids with high feed-in tariffs.
- Mains First: Prioritizes Mains Power charging. PV charging starts only if Mains fails.
- Hybrid Charging: Combines PV and Mains Power charging. Prioritizes PV MPPT charging, supplementing with Mains if PV energy is insufficient. Mains charging stops when PV energy is sufficient. Suitable for unstable grids, providing continuous backup power.
- Only Solar: Only PV charging is initiated; no mains charging. Most energy-efficient mode, relying solely on solar energy. Best for regions with good daylighting.

6.2 Output Modes
The inverter offers two main output modes:
- Solar First: PV and battery power the load. Maximizes green solar energy use. Switches to Mains Power if PV fails. Suitable for stable power grids.
- Mains First: Switches to inverter power supply only when Mains Power fails. Functions as a backup UPS, ideal for unstable power grids.
- Inverter First: Switches to Mains Power supply only when the battery is under-voltage. Maximizes DC energy usage, suitable for stable power grids.
- Hybrid Output and Grid Connection: In utility bypass state, if no battery is connected or the battery is full, the load is supplied by PV and utility. Surplus PV energy can be fed back to the grid if grid connection is enabled.
7. LCD Screen Operating Instructions
The inverter features an LCD screen, 3 indicator lights, and 4 operation buttons for monitoring and configuration.

7.1 Operation Buttons
| Function Key | Description |
|---|---|
| Menu/Enter/Exit Settings | Access or exit the settings menu. |
| △ | Page Number/Option Increase |
| ▽ | Page Number/Option Decrease |
| OK/Enter Options | Confirm selection within the settings menu. |
7.2 Indicators
| Indicator light | Color | Description |
|---|---|---|
| AC/INV | Yellow | Normally On: Mains Power output Flicker: Inverter output |
| CHARGE | Green | Flicker: The battery is being charged. Normally On: The charging is completed. |
| FAULT | Red | Normally On: Fault status |
7.3 Real-time Data Viewing
On the LCD main screen, press the △ or ▽ button to cycle through real-time data pages.
7.4 Setup Parameters Description
The inverter allows configuration of various parameters through the LCD screen. To enter the setting menu, press the Menu/Enter/Exit Settings button. Use △ and ▽ to navigate parameter codes, then press Menu/Enter/Exit Settings to enter editing mode. Use △ and ▽ to adjust values, and press Menu/Enter/Exit Settings to confirm and return to parameter selection.
Key parameters include:
- Supply Priority Mode (01): AC1ST (Mains First), BT1ST (Inverter First), PV1ST (Solar First).
- Output Frequency (02): 50.0Hz or 60.0Hz (default for 120V machine).
- AC Input Voltage Range (03): UPS (90-140V) or APL (90-140V).
- Battery to Mains (04): Voltage threshold (default 43.6V) for switching from inverter to mains power.
- Mains to Battery (05): Voltage threshold (default 56.8V) for switching from mains to inverter.
- Charging Mode (06): Hybrid (default), AC1ST (Mains First), PV1ST (Solar First).
- Maximum Charging Current (07): 0-100A (default 60A).
- Battery Type (08): USER, SLd (Sealed Lead-Acid), FLd (Flooded Lead-Acid), GEL (Gel Lead-Acid, default), LFP14/LFP15/LFP16 (Lithium), NCM13/NCM14 (Lithium).
- Boost Voltage (09): 48V-58.4V (default 57.6V).
- Maximum Boost Duration (10): 5mins-900mins (default 120mins).
- Float Charge Voltage (11): 48V-58.4V (default 55.2V).
- Over-discharge Voltage (12): 40V-52V (default 42V).
- Over-discharge Delay Time (13): 5s-50s (default 5s).
- Battery Under-voltage Alarm Point (14): Default 44V.
- Battery Discharge Limit Voltage (15): 40V-52V (default 40V).
- Equalization Charge (16): DIS (Disable) or ENA (Enable, default).
- Equalization Voltage (17): 48V-58V (default 58V).
- Equalization Charging Time (18): 5mins-900mins (default 120mins).
- Equalized Charging Delay (19): 5mins-900mins (default 120mins).
- Equalization Charge Interval Time (20): 0-30 days (default 30 days).
- Equalization Charging Start-Stop (21): ENA (Start) or DIS (Stop).
- ECO Mode (22): DIS (Disable, default) or ENA (Enable).
- Overload Automatic Restart (23): DIS (Disable) or ENA (Enable, default).
- Auto Restart Upon Over-temperature (24): DIS (Disable) or ENA (Enable, default).
- Buzzer Alarm (25): DIS (Disable) or ENA (Enable, default).
- Mode Change Reminder (26): DIS (Disable) or ENA (Enable, default).
- Inverter Overload to Bypass (27): DIS (Disable) or ENA (Enable, default).
- Current of Charging Under Grid Electricity (28): 0-40A (default 40A).
- RS485 Address Setting (30): 1-254 (default 1).
- AC Output Mode (31): SIG (Single machine), PAL (Single-phase parallel), 2P0/2P1/2P2 (Split-phase parallel), 3P1/3P2/3P3 (Three-phase parallel).
- Communication Function (32): SLA (PC/telecommunication control) or 485 (485-BMS communication).
- BMS Communication Protocol (33): Select brand (PAC, RDA, AOG, OLT, HWD, WOW, PYL, UOL).
- Battery Under-Voltage Recovery Point (35): 44V-54.4V (default 52V).
- Max PV Charger Current (36): 0-100A (default 80A).
- Battery Recharge Recovery Point (37): 44V-54V (default 52V).
- AC Output Rated Voltage (38): 100/105/110/120Vac (default 120Vac).
- Charge Current Limiting Method (39): LC SET, LC BMS, LC INV.
- Sectional Charging/Discharge Functions (40-45, 47-52): Time-slot settings for charging and discharging.
- Leakage Protection Function (56): DIS (Disable) or ENA (Enable).
- Stop Charging Current (57): Default 2A.
- Discharge Alarm SOC Setting (58): Default 15%.
- Cut-off Discharge SOC Settings (59): Default 5%.
- Cut-off Charge SOC Settings (60): Default 100%.
- Switch to Mains SOC Settings (61): Default 10%.
- Switch to Inverter Output SOC Settings (62): Default 100%.
7.5 Battery Type Parameters
The inverter supports various battery types, each with specific default and adjustable parameters for optimal performance and protection. These parameters include overvoltage disconnection, fully charged recovery point, equalizing charge voltage, boost charge voltage, floating charge voltage, undervoltage alarm, low voltage disconnection, discharge limit, over-discharge delay, equalizing charge duration, equalizing charge interval, and boost charge duration.
Refer to the detailed tables in the full user manual (PDF) for specific voltage and time settings for Sealed Lead-Acid (SLD), Colloidal Lead-Acid (GEL), Vented Lead-Acid (FLD), User-defined, NCM13, NCM14, LFP16, LFP15, and LFP14 battery types.
8. Other Functions
8.1 Dry Contact
This dry contact controls the ON/OFF of a diesel generator for battery charging. Normally, the NC-N point is closed and NO-N is open. When battery voltage reaches the low voltage disconnection point, the relay coil energizes, closing NO-N and opening NC-N. NO-N can drive resistive loads (125VAC/1A, 230VAC/1A, 30VDC/1A).
8.2 RS485 Communication Port
The RS485 port offers two functions:
- RS485-2: For direct communication with a host computer to monitor equipment status and set parameters.
- RS485-1/RS485-2: For direct connection to an optional RS485 to WiFi/GPRS communication module, allowing monitoring and control via a mobile app.
8.3 USB Communication Port
This USB port enables communication with PC host software. Install the "USB to serial chip CH340T driver" on your computer to use this function.
8.4 Parallel Communication Function (Parallel Operation Only)
This port facilitates communication between parallel modules. Each inverter has two DB15 ports (male and female). When connecting, ensure male connects to female. Do not connect male to male or female to female. Secure connections with screws.
8.5 Current Sharing Detection Function (Parallel Operation Only)
This port detects current sharing among parallel modules. Each inverter has two current sharing detection ports. Either port can be used for convenience when connecting to other models for parallel operation. Ensure the red and black current sharing lines are not manually exchanged and are tightened with screws.
9. Parallel Installation Guide
The PowMr Hybrid Solar Inverter supports parallel operation with up to six units. When using this function, ensure the parallel communication line and current sharing detection line are firmly and reliably connected.
9.1 Precautions for Connecting Parallel Lines
- Battery Wiring: For single or split-phase parallel connections, ensure all inverters are connected to the same battery, with correct polarity (BAT+ to BAT+, BAT- to BAT-), same wiring length, and line diameter.
- AC OUT Wiring: For single-phase parallel connections, ensure L-to-L, N-to-N, and PE-to-PE connections for all inverters, with correct wiring length and line diameter. For split-phase, ensure N-to-N and PE-to-PE. L lines of inverters connected to the same phase must be joined, but L lines of different phases cannot.
- AC IN Wiring: For single-phase parallel connections, ensure L-to-L, N-to-N, and PE-to-PE connections. Ensure a single, consistent AC source input. For split-phase, ensure N-to-N and PE-to-PE. L lines of inverters connected to the same phase must be joined, but L lines of different phases cannot.
- Parallel Communication Line: Use a DB15 standard computer cable. Follow a "one-in-one-out" rule (male connector out to female connector in). Tighten with self-contained screws.
- Current Sharing Detection Line: Use a twisted connection line. Connect the inverter's current sharing line to the current sharing green port of the inverter to be paralleled (either port). Do not connect the inverter's own current sharing ports to each other. Ensure red and black lines are not exchanged and are tightened.
- System Wiring Diagram: Refer to the provided diagrams to ensure all wiring is correct and reliable before power on.
- Adding New Inverters: If adding a new inverter to an existing parallel system, disconnect battery input, PV input, AC input, and AC output, and power off all inverters before reconnecting.
9.2 Photovoltaic Connection - Parallel Operation Mode
Each inverter must be connected to a dedicated photovoltaic array. Multiple inverters cannot be connected to the same PV array, as this may cause irreversible damage.

Refer to the full user manual (PDF) for detailed schematic diagrams of parallel connections in single phase, two phase, and three phase configurations.
10. Protection Functions
The PowMr Hybrid Solar Inverter is equipped with comprehensive multi-protection functions to ensure stable and secure operation:
- PV Current/Power Limiting: Charges at rated current/power if PV array output exceeds limits.
- PV Night Reverse-Current: Prevents battery discharge through the PV module at night.
- Mains Input Over/Under Voltage: Switches to inverter mode if mains voltage is outside 90V-140V range.
- Battery Over Voltage: Stops PV and mains charging if battery voltage reaches overvoltage disconnection point.
- Battery Low Voltage: Stops battery discharging if battery voltage reaches low voltage disconnection point.
- Load Output Short Circuit: AC output turns off immediately and restarts after 1 second.
- Heat Sink Over Temperature: Stops charging/discharging if internal temperature is too high, resumes when normal.
- Overload Protection: Reports error and turns off output after 5 minutes (for 102-110% load) or 10 seconds (for 110-125% load). For loads >125%, output turns off immediately.
- PV Reverse Polarity: Machine will not be damaged if PV polarity is reversed.
- AC Reverse Protection: Prevents battery inverter AC current from reversely inputting to Bypass (off-grid mode).
- Bypass Overcurrent: Built-in AC input overcurrent protection circuit breaker.
- Battery Input Overcurrent: Switches to load if battery discharge current exceeds maximum for 1 minute.
- Battery Input Protection: Inverter fuse blows if battery is reversely connected or short-circuited.
- Charge Short Protection: Inverter protects and stops output current if external battery port is short-circuited during PV or AC charging.
- CAN Communication Loss: Alarms if CAN communication is lost in parallel operation.
- Parallel Connection Error: Protects equipment if parallel line is lost.
- Parallel Battery Voltage Difference: Protects equipment if battery connection is inconsistent or voltage differs significantly.
- Parallel AC Voltage Difference: Protects equipment if AC IN input connection is inconsistent.
- Parallel Current Sharing Fault: Protects if load difference is large due to improper current sharing line connection or device damage.
- Synchronization Signal Fault: Protects if there is a fault in the guidance signal between parallel buses.

11. Fault Codes and Handling Measures
The inverter displays specific fault codes to indicate issues. Refer to the table below for common fault codes and their remedies.
| Fault code | Fault name | Remedy |
|---|---|---|
| Display | No display on the screen | Check if the battery PV air switch is closed; if ON, press any button to exit screen sleep mode. |
| 【06】 | Battery overvoltage protection | Measure if battery voltage exceeds rated, turn off PV array and Mains AC switches. |
| 【01】 | Battery undervoltage protection | Charge battery until it returns to low voltage disconnection recovery voltage. |
| 【21】 | Fan failure | Check if fan is not turning or blocked. |
| 【19】【20】 | Heat sink over temperature protection | When device temperature cools below recovery, normal charge/discharge resumes. |
| 【13】【14】 | Bypass overload protection, inverter overload protection | 1. Reduce power equipment usage; 2. Restart unit to resume load output. |
| 【17】 | Inverter short circuit protection | 1. Check load connection and clear short-circuit points; 2. Re-power up to resume load output. |
| 【09】 | PV overvoltage | Use multimeter to check if PV input voltage exceeds maximum allowable input voltage. |
| 【03】 | Battery disconnected alarm | Check if battery is not connected or if battery circuit breaker is not closed. |
| 【40】【43】 | Parallel connection fault | Check whether the parallel line is not connected well, such as loose or wrong connection. |
| 【35】 | Parallel ID setting error | Check whether the setting of parallel ID number is repeated. |
| 【37】 | Parallel current sharing fault | Check whether the parallel current sharing line is not connected well, such as loose or wrong connection. |
| 【39】 | Inconsistent AC input source in parallel mode | Check whether the parallel AC inputs are from the same input interface. |
| 【42】 | Inconsistent system firmware version in parallel mode | Check whether the software version of each inverter is consistent. |
12. Maintenance
To ensure optimal long-term performance, perform the following checks twice a year:
- Ensure airflow around the unit is not blocked and remove any dirt or debris from the heat sink.
- Inspect all exposed wires for damage (sunlight exposure, friction, dryness, pest bites). Repair or replace damaged wires as necessary.
- Verify consistency of indications and displays with device operation. Address any faults or errors promptly.
- Check all wiring terminals for corrosion, insulation damage, signs of high temperature or burning/discoloration. Tighten screws as needed.
- Inspect for dirt, nesting insects, and corrosion. Clean as required.
- If the arrester has failed, replace it immediately to prevent lightning damage to the unit or other equipment.
WARNING: Danger of electric shock! Before performing maintenance, ensure all power supplies are disconnected and all capacitors are discharged.
The manufacturer is not liable for damage caused by:
- Improper use or installation.
- PV module open circuit voltage exceeding maximum allowable rated voltage.
- Operating temperature exceeding the limited range.
- Unauthorized disassembly or repair.
- Force majeure (e.g., damage during transportation or handling).
13. Technical Specifications
General
| Parameter | Value |
|---|---|
| Model | POW-SunSmart SP5K |
| Permitted parallel number | 1~6 |
| Weight | 14kg |
| Dimension (L*W*D) | 446.9mm*350mm*133mm |
| Operating temperature range | -10°C ~ 55°C |
| Storage temperature range | -25°C ~ 60°C |
| Humidity range | 5% to 95% (Conformal coating protection) |
| Noise | ≤60dB |
| Heat dissipation | Forced air cooling, variable speed fan |
| Communication interface | USB/RS485(WiFi/GPRS)/Dry contact control |
| Certification | CE(IEC62109-1), EN61000 |
AC Mode
| Parameter | Value |
|---|---|
| Rated input voltage | 110/120Vac |
| Input voltage range | (90Vac~140Vac) ± 2% |
| Frequency | 50Hz/60Hz (Auto detection) |
| Frequency Range | 47±0.3Hz~55±0.3Hz (50Hz); 57±0.3Hz~65±0.3Hz (60Hz) |
| Overload/short circuit protection | Circuit breaker |
| Efficiency | >95% |
| Conversion time (bypass and inverter) | 10ms (typical) |
| AC reverse protection | Available |
| Maximum bypass overload current | 63A |
Inverter Mode
| Parameter | Value |
|---|---|
| Output voltage waveform | Pure sine wave |
| Rated output power | 5000VA |
| Rated output power | 5000W |
| Power factor | 1 |
| Rated output voltage | 120Vac (100/105/110Vac Settable) |
| Output voltage error | ±5% |
| Output frequency range | 50Hz±0.3Hz; 60Hz±0.3Hz |
| Maximum Efficiency | >92% |
| Peak power | 10000VA |
| Loaded motor capability | 4HP |
| Rated battery input voltage | 48V (Minimum starting voltage 44V) |
| Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm/overvoltage recovery... settable on LCD screen |
| Power saving mode self-consumption | Load ≤ 50W |
AC Charging
| Parameter | Value |
|---|---|
| Battery type | Lead acid or lithium battery |
| Maximum charge current (can be set) | 0-40A |
| Charge current error | ±3Adc |
| Charge voltage range | 40-58Vdc |
| Short circuit protection | Circuit breaker and blown fuse |
| Circuit breaker specifications | 63A |
| Overcharge protection | Alarm and turn off charging after 1 minute |
PV Charging
| Parameter | Value |
|---|---|
| Maximum PV open circuit voltage | 500Vdc |
| PV operating voltage range | 120-500Vdc |
| MPPT voltage range | 120-450Vdc |
| Battery voltage range | 40-60Vdc |
| Maximum PV input power | 5500W |
| Maximum PV input current | 22A |
| PV charging current range (can be set) | 100A |
| Charging short circuit protection | Blown fuse |
| Wiring protection | Reverse polarity protection |
Hybrid Charging (AC charger + PV charger)
| Parameter | Value |
|---|---|
| Max charger current (can be set) | 100A |
14. User Tips
- For optimal performance, ensure proper ventilation around the inverter to prevent overheating.
- Regularly check wiring connections for tightness to avoid potential issues.
- When setting up parallel systems, double-check all communication and current sharing lines to prevent operational errors.
- Familiarize yourself with the LCD display and fault codes for quick troubleshooting.
- Consider using the time slot control feature to optimize energy usage based on local electricity tariffs.
15. Warranty and Support
This user manual contains all safety, installation, and operating instructions for the POW-SunSmart Series all-in-one solar charge inverter. All information, including images and symbols, is the property of PowMr. Unauthorized use, in whole or in part, of the content is strictly prohibited.
For the latest user manual, updates, or technical support, please visit the official PowMr website or contact customer service.
Contact Information:
SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
Tel/Fax: +86755-28219903
Email: support@powmr.com
Web: www.powmr.com
Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China
User Manual (PDF): A detailed user manual in PDF format is available for download. View User Manual (PDF)