1. Introduction
The XKC-Y25-PNP is a non-contact liquid water level sensor designed for external mounting on non-metallic containers. It utilizes advanced signal processing technology and high-speed signal processing chips to detect liquid levels without direct contact, offering high stability, sensitivity, and strong interference immunity. This sensor is suitable for various applications requiring precise liquid level monitoring, including those involving boiling water.

Description: A white, disc-shaped sensor with a red indicator light, connected to a black cable with a 4-pin white connector. The sensor body has model information and wiring labels.
2. Setup and Installation
2.1 Mounting the Sensor
- Ensure the container surface where the sensor will be mounted is clean and dry.
- The sensor is designed for non-contact detection and should be placed on the outer wall of the non-metallic container.
- The maximum sensing thickness (sensitivity range) is 0-20mm. Position the sensor firmly against the container wall within this range for optimal performance.
- Secure the sensor in place using appropriate adhesive or mounting brackets (not included) to prevent movement.
2.2 Wiring Diagram
The sensor features a 4-pin connector. Refer to the labels on the sensor and the image below for correct wiring:

Description: A close-up view of the XKC-Y25-PNP sensor and its 4-pin connector. The sensor body clearly shows labels for wiring: '棕 5-12V 黄 OUT', '蓝 GND', '黑 M'.
| Wire Color (Label) | Function | Description |
|---|---|---|
| Brown (棕) / Yellow (黄) | VCC (Power Input) | Connect to DC 5-12V power supply. |
| Blue (蓝) | GND (Ground) | Connect to the ground of the power supply. |
| Black (黑) | M (Output) | Signal output. This is a PNP type output. |
Note: Ensure power is off before making any wiring connections to prevent damage to the sensor or connected equipment.
3. Operating Instructions
- Once properly mounted and wired, apply power (DC 5-12V) to the sensor.
- The sensor will continuously monitor the liquid level at its detection point.
- When liquid is detected at the sensor's position, the output (Black 'M' wire) will change state. As this is a PNP sensor, the output will typically switch to a high state (close to VCC) when liquid is detected.
- The red LED indicator on the sensor will illuminate when liquid is detected, providing visual feedback.
- The sensor features intelligent memory and level adjustment capabilities, allowing for stable and accurate detection even with variations in liquid properties or container conditions.
4. Maintenance
The XKC-Y25-PNP sensor is designed for long-term, maintenance-free operation due to its pure electronic circuit structure and lack of mechanical moving parts. It has an IP67 protection rating, making it dust-tight and resistant to temporary immersion in water.
- Cleaning: If the sensor or container surface becomes dirty, gently wipe it with a soft, damp cloth. Avoid using abrasive cleaners or solvents.
- Inspection: Periodically check the sensor's mounting to ensure it remains firmly attached to the container.
- Environmental Conditions: Ensure the sensor operates within its specified temperature and humidity ranges for optimal performance and longevity.
5. Troubleshooting
- Sensor Not Detecting Liquid:
- Verify that the sensor is receiving the correct DC 5-12V power supply.
- Check all wiring connections for proper polarity and secure contact.
- Ensure the sensor is mounted correctly on the outside of the container and the container wall thickness is within the 0-20mm sensing range.
- Confirm the container material is non-metallic.
- Intermittent Detection:
- Check for any vibrations or movement of the sensor or container that might affect consistent contact.
- Ensure the container surface is clean and free from condensation or debris at the sensor's location.
- Verify the power supply is stable and free from fluctuations.
- Sensor LED Not Illuminating:
- Confirm power is supplied to the sensor.
- Check if liquid is actually present at the detection point.
- If power is present and liquid is detected but the LED remains off, the sensor may be faulty.
6. Specifications
| Parameter | Value |
|---|---|
| Model | XKC-Y25-PNP |
| Operating Voltage | DC 5-12V |
| Humidity Range | 5% ~ 100% |
| Working Temperature | -20 ~ 80 ℃ |
| Current Consumption | 5mA |
| Power Consumption | 200 uA |
| Output Current | 1-100mA |
| Response Time | 500 mS |
| Sensing Thickness Range | 0-20mm |
| Sensor Protection Rating | IP67 |
| Dimensions | 28mm x 28mm x 17mm |
| Output Type | PNP |
7. User Tips
No specific user tips were available from provided reviews or Q&A content. For best results, ensure the sensor is mounted on a flat, clean surface of the container and that the container material is uniform in thickness at the detection point.
8. Warranty and Support
For warranty information, please refer to the terms and conditions provided by your original seller or retailer at the time of purchase. For technical support or further inquiries, please contact the product manufacturer or your point of purchase.
A detailed user manual in PDF format may be available from the seller: View User Manual (PDF)