SNDWAY SW-DS50

Contents

SNDWAY SW-DS50 Laser Distance Meter User Manual

Models: SW-DS50, SW-DS70, SW-DS100, SW-DS120

1. Safety Regulations

Before using the instrument for the first time, please read the safety terms and operating instructions carefully. Failure to use the instrument according to the instructions in this manual may cause damage to the instrument, affect measurement accuracy, or cause personal injury to the user or third parties.

  • Do not open or repair the instrument by yourself in any way. It is strictly forbidden to illegally modify or change the performance of the instrument's laser emitter.
  • Store the instrument properly and do not place it where children can reach it to avoid misuse.
  • It is strictly forbidden to shine the instrument's laser beam into your own or others' eyes or other body parts. It is strictly forbidden to shine the laser beam on highly reflective surfaces.
  • Electromagnetic radiation from the instrument may interfere with other equipment and devices. Do not use this instrument near aircraft or medical equipment. Do not use the instrument in flammable or explosive environments.
  • Used batteries and scrapped instruments should not be disposed of with household waste. Please dispose of them in accordance with national or local laws and regulations.
  • If the instrument has any quality problems, or if you have any questions about using the instrument, please contact your local dealer or SNDWAY instrument manufacturer in time for a solution.

2. Product Overview

The SNDWAY SW-DS series laser distance meters are designed for precise and stable measurements, featuring a large LCD with backlight for clear visibility in various conditions. These devices are equipped with an imported STM32 chip for efficient processing and include an 18mm lens for enhanced signal reception compared to standard 12mm lenses.

SNDWAY SW-DS120 Laser Distance Meter with Red Laser and Angle Measurement
SNDWAY SW-DS120 Laser Distance Meter with Red Laser and Angle Measurement capability up to 120M.
SNDWAY Laser Distance Meter on a table, showing laser beam for precision and stability
The SW-DS series offers high precision and stability for accurate measurements.
Close-up of the large LCD with backlight on the laser distance meter
Large LCD with Backlight supports better visibility in low-light conditions.
Diagram showing the internal lens structure of the SNDWAY laser distance meter compared to others
The device features an 18mm lens for superior laser emission and reception compared to typical 12mm lenses, enhancing measurement accuracy.
Double aperture photometric compensation for increased ranging performance
Double aperture photometric compensation increases ranging performance through low light compensation and light filtering.
Rangefinder Core Chip Technology diagram showing STM32 chip for stability and processing speed
Equipped with an imported STM32 chip for stable, efficient, and precise measurements.
SNDWAY laser distance meter showing IP54 waterproof, dust-proof, and anti-fall features
Top-quality ABS injection molding ensures IP54 waterproof, dust-proof, and anti-fall protection.

3. Package Contents

Please check the following list to ensure all accessories are included and complete:

ItemDescriptionUnitQuantity
1Main UnitSet1
2Instrument PouchPiece1
3Hand StrapStrap1
41.5V AAA BatterySection2
5User ManualBook1
6Warranty CertificateSheet1
7Color BoxPiece1
Contents of the SNDWAY SW-DS50 package including the device, hand strap, gift box, manual, reflective plate, and bag.
The package includes the laser distance meter, hand strap, gift box, user manual, reflective plate, and a protective bag.

4. Setup and Function Settings

4.1. Battery Installation

  1. Open the battery compartment cover on the back of the instrument.
  2. Insert two 1.5V AAA alkaline batteries according to the polarity indicators.
  3. Close the battery compartment cover.

Note: If the instrument will not be used for a long time, please remove the batteries to prevent corrosion to the instrument's main unit.

Product demonstration video showing unboxing, battery installation, and various measurement functions.

4.2. Power On/Off

  • Power On: In the off state, press the READ button. The instrument and laser will start simultaneously, and the instrument will enter the measurement mode.
  • Power Off: In the on state, long press the OFF/CLEAR button for 3 seconds to turn off the instrument. If no operation is performed on the instrument within 150 seconds, it will automatically shut down.

4.3. Unit Settings

Long press the U button to enter the measurement unit adjustment state. You can reset the current measurement unit. The default unit is 0.000m. The instrument provides 6 different units to choose from.

4.4. Measurement Reference Setting

Short press the U button to switch between front-end and rear-end measurement references. The system defaults to the rear-end reference.

4.5. Delay Measurement

Long press the U button to enable delay measurement mode. The screen will display "SEC" and the default delay time is 5 seconds. You can adjust the value using the +/- button. Press READ to start the countdown, and measurement will begin after the countdown ends.

4.6. Backlight On/Off

The instrument's backlight turns on and off automatically. After pressing any button, the backlight will stay on for 15 seconds. After 15 seconds, if no operation is performed, the instrument will automatically turn off the backlight to save power.

4.7. Sound On/Off

Long press the +/- button to turn the beeping sound on or off.

5. Operating Instructions

SNDWAY laser distance meter showing angle measurement of 60 degrees
The device can measure angles, as shown with a 60-degree angle.
Electronic angle sensor for one-key angle measurement and height measurement
Electronic angle sensor enables one-key angle and height measurement, with real-time refresh.

5.1. Display and Keyboard Layout

Diagram of the SNDWAY laser distance meter display and keyboard layout
Detailed layout of the display and keyboard for the SNDWAY laser distance meter.

Display:

  • Power Supply Indicator
  • Record Indicator
  • Length, Area, Volume and Pythagorean Measurement Mode
  • Laser On Indicator
  • Angle Indicator
  • Maximum Value Indicator
  • Auxiliary Display
  • Minimum Value Indicator
  • Major Display

Keyboard:

  • Turn on/Measuring (READ)
  • Sound/Addition/Subtraction (+/-)
  • Area/Volume/Pythagorean Measuring (Area/Volume)
  • Reference Point/Unit Switch (U)
  • Turn off/Remove (OFF/CLEAR)
  • Save (Save)

5.2. Single Measurement

In measurement mode, press the READ button. The instrument will emit a laser and lock the measurement point. Press the READ button again to perform a single distance measurement, and the result will be displayed in the main display area.

Diagram showing distance measurement with laser from the device to a wall
Distance measurement: Point the laser at the target and press READ.

5.3. Continuous Measurement

In measurement mode, long press the READ button to enter continuous measurement state. The auxiliary display area on the screen will show the maximum and minimum measured values during this continuous measurement process. The main display area will show the current measured value. Short press READ or OFF/CLEAR to exit continuous measurement mode.

Diagram showing continuous measurement with laser from the device to a wall, indicating max and min values
Continuous measurement: The device tracks the maximum and minimum distances as it moves.

5.4. Area Measurement

Press the Area/Volume button once. The screen will display a square icon with one side blinking. Follow the prompts to complete the measurement:

  1. Press READ to measure the first side (length).
  2. Press READ to measure the second side (width).

The instrument will automatically calculate the area, and the result will be displayed in the main display area. The auxiliary display area will show the measured length and width of the rectangle. During the measurement process, you can press OFF/CLEAR to clear the current measurement result and re-measure. When there is no data in the display area, press OFF/CLEAR to exit area measurement mode and enter length measurement mode.

Diagram showing area measurement by measuring length (A) and width (B) of a wall
Area measurement: Measure length (A) and width (B) to calculate the area.

5.5. Volume Measurement

Press the Area/Volume button twice. The system will enter volume measurement state, and the instrument will enter volume mode. A cube icon will flash on the screen. Follow the prompts to complete the measurement:

  1. Press READ to measure the first side (length).
  2. Press READ to measure the second side (width).
  3. Press READ to measure the third side (height).

The instrument will automatically calculate the volume, and the result will be displayed in the main display area. The auxiliary display area will show the measured length, width, and height of the cube. During the measurement process, you can press OFF/CLEAR to clear the current measurement result and re-measure. When there is no data in the display area, press OFF/CLEAR to exit volume measurement mode and enter length measurement mode.

Diagram showing volume measurement by measuring length (A), width (B), and height (C) of a room
Volume measurement: Measure length (A), width (B), and height (C) to calculate the volume.

5.6. Wall Area Measurement

Short press the Area/Volume button three times. The screen will display a wall icon. Follow the prompts to complete the operation:

  1. Press READ to measure the height of the wall.
  2. Press READ to measure the width of the first wall. The instrument will automatically calculate the area of the wall = height × width 1.
  3. Press READ to measure the width of the second wall. The instrument will automatically calculate the total area of the walls = height × (width 1 + width 2).
  4. Continue in the same way, pressing READ to measure the width of wall 'n'. The total area of the walls = height × (width 1 + width 2 + ... + width n).

During the measurement process, you can press OFF/CLEAR to clear the current measurement result and re-measure. When there is no data in the display area, press OFF/CLEAR to exit wall area measurement mode and enter length measurement mode.

5.7. Pythagorean Indirect Measurement

The instrument has four built-in modes for measuring single-side distances of triangles using the Pythagorean theorem, allowing users to perform indirect measurements in specific complex environments.

Diagram showing Pythagorean measurement for height (A, B, C sides of a triangle)
Pythagorean measurement: Measure sides A, B, and C to calculate indirect distances.
Diagram showing Pythagorean measurement for height (A, B, C sides of a triangle) with angle D
Pythagorean measurement: Another method for calculating height using sides A, B, C and angle D.

5.7.1. Angle Measurement for Height

Short press the Area/Volume button four times to enter the angle measurement for height mode. According to the screen prompts, first measure the length of the virtual hypotenuse (a) and simultaneously measure the angle between the hypotenuse and the base. The instrument will automatically calculate the horizontal distance (b) and vertical height (h).

5.7.2. Measuring the Hypotenuse of a Right Triangle

Click the Area/Volume button five times. The screen will display a right triangle icon with a right-angle side blinking. According to the screen prompts, first measure the length of one virtual side (a). Then press READ to measure the length of the other virtual side (b). The instrument will automatically calculate the length of the actual hypotenuse (x).

5.7.3. Measuring a Side of a Triangle (Mode 3)

Click the Area/Volume button six times. The screen will display a triangle icon with a slanted side blinking. According to the screen prompts, first measure the length of one virtual side (a). Then measure the middle virtual side (b), and finally measure the other virtual side (c). The instrument will automatically calculate the length of the actual side of the triangle (x).

5.7.4. Measuring a Side of a Triangle (Mode 4)

Click the Area/Volume button seven times. The screen will display a triangle icon with a slanted side blinking. According to the screen prompts, first measure the length of one virtual side (a). Then measure the virtual side as shown in the figure (b), and finally measure the other virtual slanted side as shown in the figure (c). The instrument will automatically calculate the length of the actual right-angle side (x).

Important: In Pythagorean measurement mode, the right-angle side must be shorter than the hypotenuse for the instrument to calculate; otherwise, the instrument will display an error signal. To ensure measurement accuracy in Pythagorean mode, make sure to measure from the same starting point and follow the measurement order of hypotenuse, then right-angle sides.

5.8. Add/Subtract Measurement Function

Single distance measurements can be added or subtracted. After obtaining a measurement result for a single distance, press the +/- button to enter the add/subtract function selection. Short press +/- again, and a "+" will appear in the main display area, entering addition mode. The screen will display the sum of the previous measurement and the current measurement. Press +/- again, and a "-" will appear in the main display area, entering subtraction mode. The screen will display the difference between the previous measurement and the current measurement. Cycle through add/subtract by pressing +/-.

This function also applies to area and volume measurements.

6. Measurement Record Storage Function

If there is current data in measurement mode, long press the Save button for 3 seconds to automatically store the current measurement data into the instrument's memory. In area, volume, and triangular indirect measurement modes, the instrument will save the complete record of that measurement mode after all tests are completed.

6.1. Browse/Delete Records

Short press the Save button to query the stored measurement data. Use the Save button to scroll forward through records, and the +/- button to scroll backward. While viewing records, short press OFF/CLEAR to delete the current record, and long press OFF/CLEAR to clear all records. You can exit this state by pressing the U or READ button.

7. Self-Calibration Function

To ensure the accuracy of the instrument, a self-calibration function is provided. To calibrate:

  1. In the off state, continuously press and hold the U button.
  2. Then press the READ button to power on, then release the READ button.
  3. Continue holding U until "CAL" appears at the bottom of the screen with a flashing number. This indicates entry into self-calibration mode.
  4. At this point, the user can adjust the value using the +/- button according to the instrument's error. The adjustment range is -9 to +9mm.

Example: If the actual distance is 3.780m and the measured value is 3.778m (2mm less than the actual value), enter calibration mode and use the +/- button to increase the calibration value by 2mm. If the measured value is 3.783m (3mm more than the actual value), enter calibration mode and decrease the calibration value by 3mm.

After adjustment, press the READ button to save the calibration result.

8. Troubleshooting

During use, the main display area may show the following error messages:

MessageReasonSolution
ErrMeasurement range exceededUse the instrument within its specified range.
Err1Signal too weakTarget point has strong reflective ability.
Err2Signal too strongTarget point has weak reflective ability.
Err3Battery voltage too lowReplace batteries.
Err4Operating temperature exceededUse the instrument in the specified environment.
Err5Pythagorean measurement violationRe-measure, ensuring the hypotenuse is greater than the right-angle side.
Err6Angle sensor errorReturn to factory for repair.

9. Specifications

ItemSpecifications
Working Range0.05-40m/60m/80m/100m/120m
Distance measurement precision±2mm *
Measurement unit optionsm/in/ft
Continuous measurement functionYes
Outdoor target reflection boardNo
Area measurement functionYes
Volume measurement functionYes
Pythagorean proposition measurement functionFull mode
Add and subtract measurement functionYes
Delay MeasurementYes
Min/Max valueYes
Max storage30 units
Automatic backlightYes
Buttons/Keys soundYes
Laser levelII
Laser type635nm, <1mW
Automatically cut off laser20s
Automatic shutdown150s
Storage temperature-20°C~60°C
Working temperature0°C~40°C
Storage humidity20%~80%RH
Battery2x1.5V AAA
Battery life8000 times for single measurement
Angle Range±90°
Dimension112*50*25mm

* "d" represents the actual distance.

** In harsh environments such as strong sunlight, large temperature fluctuations, weak reflection from reflective surfaces, or low battery power, measurement results may have significant errors. In such cases, it is recommended to use a target reflective plate for better results.

Dimensions of the SNDWAY laser distance meter: 112mm height, 50mm width, 25mm depth
Dimensions of the SNDWAY laser distance meter: 112mm height, 50mm width, 25mm depth.

10. Maintenance

  • Do not store the instrument in high temperature and high humidity environments for a long time.
  • When not using the instrument for a long time, please place it in the provided instrument pouch and store it in a cool, dry place.
  • Keep the instrument surface clean. Wipe off dust with a damp soft cloth. Do not use corrosive cleaning solutions.
  • Wipe the laser window and focusing lens according to the method for wiping optical components.

11. User Tips

  • Accuracy Verification: Based on user feedback, the device is accurate. It's a good practice to test it against a known measurement to confirm its precision, especially after self-calibration.
  • Digital Level: Users find the integrated digital level very convenient for ensuring straight and level measurements.
  • Battery Care: Always remove batteries if storing the device for extended periods to prevent potential damage from leakage.

12. Warranty and Support

For any quality issues or questions regarding the use of the instrument, please contact your local dealer or the SNDWAY instrument manufacturer immediately for assistance.

Dongguan Senwei Electronics Co., Ltd.

  • Phone: 0769-85265688
  • Fax: 0769-85116652
  • Website: www.sndway.com
  • National Consultation Hotline: 400-125-6969
  • Address: Senwei Technology Park, 58 Tuanjie Road, Humen Town, Dongguan City

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.