STEPPERONLINE CL57Y

Contents

STEPPERONLINE CL57Y Nema 23 Closed Loop Stepper Motor and Easy Servo Driver Kit

User Manual

Model: CL57Y | Brand: STEPPERONLINE

1. Introduction

Thank you for choosing the STEPPERONLINE CL57Y Closed Loop Stepper Driver Kit. This manual provides essential information for the safe and effective use of your product. Please read it carefully before installation and operation to ensure proper functionality and to prevent potential damage or injury.

The CL57Y driver utilizes a new generation of 32-bit DSP control technology and power angle control, enabling speeds up to 3000rpm. This significantly reduces high-speed torque attenuation compared to ordinary open-loop drivers, enhancing the high-speed performance and torque of the stepper motor. It also effectively minimizes motor heating and vibration, improving machine processing efficiency and accuracy. The driver incorporates load-based current control technology to further reduce motor heat and extend motor service life. Built-in position and alarm output signals facilitate monitoring and control by a host computer, with an integrated position out-of-tolerance alarm function for added safety.

2. Safety Information

Improper operation can lead to extremely serious consequences.

! Attention: Remind you to pay attention to the main points in the text.

! Warning: Indicates that improper operations may result in personal injury or equipment damage.

The design and manufacture of this product do not inherently provide protection against personal injury from mechanical systems. Users must implement appropriate safety measures during the design and manufacturing of mechanical systems to prevent accidents caused by improper operation or product anomalies.

Due to continuous product improvements, the contents of this manual are subject to change without prior notice. The manufacturer is not responsible for any modifications made to the product by the user.

3. Product Overview

3.1 Key Features

  • Intelligent current adjustment based on load conditions.
  • Compatible with Nema 23/24 series stepper motors.
  • Optocoupler isolation for differential signal input.
  • Impulse response frequency up to 200KHz.
  • Voltage input range: DC24-50V.
  • Integrated protection features: overcurrent, overvoltage, undervoltage, and position error protection.

3.2 Application Fields

This product is suitable for a wide range of large automation equipment and instrument applications, including but not limited to:

  • Engraving machines
  • Special industrial sewing machines
  • Stripping machines
  • Marking machines
  • Cutting machines
  • Laser phototypesetting equipment
  • Plotters
  • CNC machine tools

4. Specifications

4.1 Electrical Characteristics (CL57Y Driver)

Argument Minimum Value Typical Value Maximum Value Unit
Continuous output current - 2.3 5.6 A
Input supply voltage 24.0 - 50.0 Vdc
Logic input current 1.0 - 7.5 mA
Pulse frequency - - 200 kHz
Insulation resistance 10 - - MΩ

4.2 General Specifications

Property Value
Holding Torque 3.0Nm (424.83oz.in)
Current / Phase 5A
Step Angle (degrees) 1.8deg
Phase 2
Model Number 1-CL57Y-S30-1M5
Type HYBRID
Certification CE, ROHS
Product Type Nema 23 Closed Loop Stepper Motor
Frame Size Nema 23 (57 x 57mm)
Body Length 122mm
Shaft Length 22mm
D-Cut Length 15mm
Cable Length 1500mm
Output Circuit Type Differential type
Encoder Type Optical Incremental
Encoder Resolution 1000PPR (4000CPR)
Output Signal Channels 2 channels

4.3 Operating Environment

Category Condition
Cooling Mode Natural cooling
Use Occasion Away from other heating equipment; avoid dust, oil mist, corrosive gas, strong vibration.
Temperature 0℃ ~ 50℃
Humidity 40 - 90%RH (non-condensation)
Vibration 10 ~ 55Hz / 0.15mm
Storage Temperature -20℃ ~ +70℃

5. Setup and Installation

5.1 Mounting Dimensions

The following diagram illustrates the mounting dimensions for the CL57Y driver (unit: mm).

CL57Y Stepper Servo Driver with dimensions and DIP switch table
Figure 1: CL57Y Stepper Servo Driver showing dimensions, DIP switch settings, and port labels.

The overall dimensions are approximately 122mm (body length) for the motor and the driver has a mounting dimension of 75.7mm x 111.5mm (excluding flanges).

5.2 Installation Methods

For optimal heat dissipation, install the driver in an upright position to facilitate strong air convection across its surface. If necessary, install a fan near the driver to force air circulation and ensure the driver operates within its reliable temperature range (typically below 50°C for the driver and 80°C for the motor).

Nema 23 Stepper Motor with CL57Y Driver
Figure 2: Nema 23 Stepper Motor and CL57Y Driver Kit.
Unboxed CL57Y Stepper Motor Kit contents
Figure 3: Contents of the CL57Y Stepper Motor Kit, showing the motor and driver.

5.3 Wiring Diagram and Port Definitions

! Important:

  • Wiring must be performed by personnel with professional ability.
  • Never perform live wiring.
  • Ensure the driver is firmly installed before wiring.
  • Do not connect the power supply incorrectly; the input voltage must not exceed 50VDC.

Refer to the following diagrams and tables for proper wiring and port identification.

CL57Y Stepper Servo Driver showing port labels and DIP switches
Figure 4: Schematic diagram of the CL57Y driver's side and top wiring, indicating status light, control signal ports, encoder input, motor input, power input, and DIP switch functions (SW1-SW8).

5.3.1 Control Signal Input Port Definition

Lead Symbol Feature Annotation
1 PU+ Pulse signal input positive end Digital input and output signals, +5V-+24V can be driven (higher than 5V need to be connected to current limiting resistance), supports common negative or common positive connection.
2 PU- Pulse signal input negative end
3 DR+ Direction signal input positive end
4 DR- Direction signal input negative end
5 MF+ Enable signal input positive end Effectively (low level) turn off the motor coil current, the motor is in the free state and the alarm signal is cleared.
6 MF- Enable signal input negative end
7 ALM+ Alarm signal output positive end Over current, over voltage, under voltage or out of the alarm, the alarm signal is valid.
8 ALM- Alarm signal output negative end

5.3.2 Power Input and Motor Port Definition

Lead Symbol Name Function
1 A+ Motor interface Two phase stepper motor connector
2 A-
3 B+
4 B-
1 V+ Power interface VDC24-50V
2 V-
Stepper motor with highly flexible cable
Figure 5: Stepper motor with its highly flexible cable, designed for durability.

5.3.3 Encoder Input Port Definition

Lead Symbol Name Function
1 EB+ Encoder B phase input positive/negative end Encoder B channel positive input/negative input
2 EB-
3 EA+ Encoder A phase input positive/negative end Encoder A channel positive input/negative input
4 EA-
5 VCC Encoder power supply Encoder 5V power supply
6 EGND Encoder GND Encoder GND

5.3.4 Input Signal Wiring Diagrams

The CL57Y driver features three digital inputs with photoelectric isolation, supporting 5V-24V input. If the input signal exceeds 24V, a series current limiting resistor is required at the signal input end. The specific wiring diagrams are as follows:

Wiring diagram for common positive connection
Figure 6: Common Positive Connection for Input Signals.
Wiring diagram for common negative connection
Figure 7: Common Negative Connection for Input Signals.

5.3.5 Output Signal Wiring Diagrams

The driver output signal is isolated by an optocoupler, and the maximum drive current is 50mA.

Wiring diagram for common negative output connection
Figure 8: Common Negative End Connection for Output Signals.
Wiring diagram for independent termination output connection
Figure 9: Independent Termination Method for Output Signals.

5.3.6 Signal Input Timing Diagram

To prevent abnormal operation of the driver control motor, adhere to the following timing diagram for input signals:

Timing diagram for PU, DR, MF signals
Figure 10: Signal Input Timing Diagram for PU, DR, and MF signals.

6. Operation

6.1 Drive DIP Switch Settings

The CL57Y driver features DIP switches for configuring various operational parameters. SW1-SW2 control basic functions like pulse mode and rotation direction, while SW5-SW8 set the micro-step subdivision.

6.1.1 Basic Function Settings (SW1-SW4)

Serial Number Dip Code Function Dip Status Set Content
1 SW1 Single and double pulse Settings ON
OFF
CW&CCW
PU&DR
2 SW2 Motor rotation direction setting ON
OFF
CCW
CW
3 SW3 Closed loop mode setting ON
OFF
Servo mode 2
Servo mode 1
4 SW4 Alarm polarity setting ON
OFF
ALM signal normal close
ALM signal normal open

6.1.2 Subdivision Settings (SW5-SW8)

SW5-SW8 allow for 16 different subdivision settings, ranging from 400 to 51200 pulses per revolution.

Dip Default (400) 800 1600 3200 6400 12800 25600 51200 1000 2000 4000 5000 8000 10000 20000 40000
SW5 ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF
SW6 ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF ON ON OFF OFF
SW7 ON ON ON ON OFF OFF OFF OFF ON ON ON ON OFF OFF OFF OFF
SW8 ON ON ON ON ON ON ON ON OFF OFF OFF OFF OFF OFF OFF OFF

7. Driver Status Indicators

The CL57Y driver provides visual feedback through its status indicator lights. The green light indicates power, while the red light signals faults. The specific fault information is detailed below:

7.1 Status Indicator Light

Color Name Features
Green Power indicator light When the power is on, the green indicator lights up.
Red Fault indicator light Drive overcurrent: flash once
Drive overvoltage: flash twice
Drive undervoltage: flash three times
Drive overtolerance: flash five times

7.2 Fault Information and Resetting

Fault Information ALM Pilot Lamp Indication Resetting Method
Overcurrent or interphase short circuit Flash once Power-off reset
Overvoltage of supply Flash twice Automatic restoration of standard voltage
The power supply voltage is too low. Flash Three times Automatic restoration of standard voltage
Drive overtolerance Flash five times Release/power-off reset or MF clear out alarm

8. Troubleshooting

This section provides common issues and their potential solutions. If the problem persists, please contact technical support.

Phenomenon Possible Situation Solution Measure
Motor failure The power light is off Check the power supply circuit. The power supply is normal.
The motor locks the shaft but does not turn The IO signal is weak and the signal current is increased.
Too little speed Selection speed.
Whether the release signal MF is connected Disconnect the MF signal.
Motor direction error Instruction input error Check whether the upper computer has a switch output.
Motor reversal Replace motor wiring sequence or adjust instruction direction.
The motor line has a break / The motor has only one direction Check whether the cable is in poor contact.
The motor wire is connected incorrectly Check the wiring.
The alarm indicator light is on The voltage is too high or low Check power supply.
The motor or drive is damaged Replace the motor or drive.
Signal interference Eliminate interference, reliable grounding.
Wrong position or speed Instruction input error Check the upper computer instructions to ensure correct output.
Speed setting error Check the DIP switch status and connect it correctly.
Motor tripping Check whether the command speed is too large and the motor selection is small.
The driver terminal is burned out Short-circuit between terminals Check the power polarity or external short circuit.
The internal resistance between terminals is too large Check whether excess solder is added to the wire and wire connection to form tin pellets.
The acceleration and deceleration time is too short Reduce the command acceleration or increase the driver filter parameter.
Motor stalling Motor torque too small Select high torque motor.
Heavy load Check the load weight and quality, adjust the mechanical structure.
Too little current Check dip switches to increase the output current of the driver.

9. Maintenance

The CL57Y driver is designed for durability and extended service life, particularly through its load-based current control technology which reduces motor heat. Regular maintenance should focus on ensuring optimal operating conditions:

  • Environmental Control: Keep the operating environment free from excessive dust, oil mist, and corrosive gases.
  • Temperature Management: Ensure adequate cooling, especially during continuous operation. If natural cooling is insufficient, consider installing a fan to maintain the driver's temperature below 50°C and the motor's temperature below 80°C.
  • Wiring Integrity: Periodically inspect all wiring connections for tightness and signs of wear or damage. Loose connections can lead to intermittent operation or component failure.
  • Firm Installation: Verify that the driver and motor are securely mounted to prevent vibration-induced issues.

No user-serviceable parts are inside the sealed driver unit. Do not attempt to open or repair the driver yourself, as this will void the warranty and may cause further damage.

10. User Tips

  • Microcontroller Compatibility: Users have successfully controlled this motor and driver kit using microcontrollers like the ESP32-S3, indicating good compatibility with common development platforms.
  • Cable Quality: The included motor cables are noted for being flexible and of good length, which can simplify installation and routing.
  • Initial Inspection: Upon receiving the kit, verify all components are present and appear in good condition. The packaging is generally robust, providing good protection during transit.

11. Warranty and Support

For detailed warranty information and technical support, please refer to the official STEPPERONLINE resources.

A comprehensive user manual in PDF format is available for download, which may contain additional diagrams and detailed instructions:

Download CL57Y User Manual (PDF)

Contact Information:

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.