EARU EAATS-A

Contents

EARU EAATS-A Series Automatic Transfer Switch User Manual

Model: EAATS-A

1. Important Safety Instructions

WARNING

The ATS series employs reliable interlocking and automatic monitoring to manage power transfer, ensuring continuous and safe operation. This product does not feature an explosion-proof structure and must not be used in flammable environments, such as those containing flammable gases, liquids, or explosives.

SAFETY INFORMATION

  1. Please use this product in accordance with the instructions in this manual.
  2. Do not disassemble this product by yourself.
  3. Pay attention to the rated voltage for use.

2. Product Overview

The EARU EAATS-A series Automatic Transfer Switch (ATS) is designed for dual-power supply systems operating at AC 50/60Hz with rated voltages up to 400V. This miniature household power switch is primarily used to monitor the status of the main power supply and a standby power supply. In the event of an abnormality in the normal power supply (e.g., under-voltage, loss of voltage, or phase failure), the device automatically and rapidly switches to the backup power source. This ensures continuous, reliable, and safe power supply to critical loads.

The product features dual electrical and mechanical interlocks, which eliminate the risk of simultaneous connection of both power sources. It is specifically designed for household rail installation and is suitable for PZ30 distribution boxes. The ATS can be operated both electrically (automatically) and manually.

The ATS is composed of a Transfer Switching Equipment (TSE) and a controller, conforming to IEC60947-6-1, Part 6-1 for multifunctional equipment and switchgear.

EARU EAATS-A Automatic Transfer Switch with eWeLink app interface
Figure 1: EARU EAATS-A Automatic Transfer Switch with eWeLink app interface.

3. Specifications

ParameterValue
Rated Working Current125A
Frequency50/60Hz
Rated Voltage Ue(L+N)AC230V
Rated Short Circuit Current iq50kA
Switching Time0.008s / 8ms
Electrical Life2000 times
Manual Operation Life5000 times
APP ControleWelink
Insulation Voltage UiAC690V
Rated Impulse Withstand Voltage8kV
StandardIEC60947-6-1
Poles2P/3P/4P
TypeMini Circuit breaker
Smart DeviceYes
Connection MethodsWiFi 2.4GHz

Dimensions

Product dimensions for EARU EAATS-A ATS switch
Figure 2: Product dimensions. Height: 96mm/3.78in, Width: 70mm/2.76in, Depth: 59mm. Pole dimensions: 2P: 108mm/4.25in, 3P: 125mm/4.92in, 4P: 143mm/5.63in.

4. Installation

4.1 Environmental Conditions

  • Ambient Air Temperature: Maximum 40℃, minimum -5℃. The average temperature within 24 hours should not exceed 35℃.
  • Altitude: The installation site altitude should not be higher than 2000m.
  • Atmospheric Conditions: At a maximum temperature of 40℃, the relative humidity should not exceed 50%. At a minimum temperature of -5℃, higher relative humidity is permissible (e.g., 90% at 25℃). Special measures should be taken to address occasional condensation due to temperature changes.
  • Pollution Grade: Conforms to Grade 3 as specified in IEC60947-6-1.
  • Installation Category: Conforms to the category specified in IEC60947-6-1.

4.2 Mounting

The ATS can be installed vertically in a control cabinet or distribution cabinet. Ensure the installation distance meets the requirements shown in the product dimension diagram (Figure 2).

35mm Standard Rail Installation of ATS switch
Figure 3: The ATS switch can be directly installed on a 35mm standard rail within a household lighting distribution box.

4.3 Key Features for Installation

  • Integrated Design: The product has a small volume and light weight, simplifying installation.
  • Rail Mounted Installation: Features a fixed buckle for easy installation on standard DIN rails.
Integrated design and rail mounted installation features
Figure 4: Integrated design and rail mounted installation features.

5. Wiring Diagram

Proper wiring is crucial for the safe and effective operation of the ATS. Refer to the diagrams below for connection details.

Wiring diagram for 2P/3P/4P ATS switch
Figure 5: General wiring diagram showing Common Power Input, Backup Power Input, Load Output, Common Control Lines, Backup Control Line, and Alternate Neutral Line.
Detailed component diagram of the ATS switch
Figure 6: Detailed component diagram. Labels include: Main terminal of common power side, Manual handle, Main power terminal and passive signal (AC230V), A power indicator, Parameter details, Manual/automatic switch, Source A, Source B, B power indicator, Status position indication, Main terminal of load connection side, Main terminal of standby power side, Standby power terminal and passive signal (AC230V).

6. Operation

6.1 Manual and Automatic Modes

The ATS switch offers both manual and automatic operation modes. This allows for convenient switching between power sources, either physically via the manual handle or remotely through the eWeLink app.

Two modes to choose freely: Manual and Automatic
Figure 7: The switch can be conveniently switched remotely via the eWeLink App or operated manually.

6.2 Automatic Transfer Logic

The ATS ensures uninterrupted power supply by automatically switching between primary and backup power sources in less than 8ms.

Diagram explaining Automatic Transfer Switch operation
Figure 8: Automatic Transfer Switch operation diagram.

Supplementary Notes (Automatic Mode):

  • Common Power Available: If the switch is in the common power position, and both common power and standby power are available, it will remain in the common power position. If common power fails, it will switch to the standby power position.
  • Standby Power Available: If the switch is in the standby position, common power is out, and standby power is available, when common power returns, it will switch back to the common power position.
  • Standby Only: If the switch is in the standby position, common power is not available, and standby power is available (e.g., from a PV system), it will remain in the standby position and will not switch to common power.

6.3 Power Failure Memory Mode

The device is equipped with a power failure memory mode, which retains the last state (ON/OFF/Last state) of the device after power is restored. This ensures consistent operation without needing to reconfigure settings after an outage.

Power Failure Memory Mode feature
Figure 9: The device retains its state after power is restored.

The ATS can be controlled remotely via the eWeLink app (available for iOS and Android). This allows for convenient management of your power transfer switch from anywhere.

Video 1: Demonstration of eWeLink App pairing and control for the ATS switch.

Pairing Instructions:

  1. Ensure your device is powered on and in pairing mode (refer to the app for specific instructions if needed).
  2. Open the eWeLink app and tap 'Add Device'.
  3. The app will search for nearby devices. Once found, select your ATS switch.
  4. Follow the on-screen prompts to complete the pairing process.

App Features:

  • Remote ON/OFF: Control the switch status from your smartphone.
  • Schedule: Set specific times for the switch to operate (e.g., turn on lights at 18:00).
  • Timer: Set a countdown timer for operations (e.g., turn off lights after 20 minutes).
  • Loop Timer: Configure repetitive on/off cycles.
  • Device Settings: Access advanced settings including LAN control, Power-on State, Inching Settings, and WiFi Settings.
eWeLink App screenshots for various control modes and settings
Figure 10: eWeLink App interface showing Schedule, Timer, Loop Timer, and Device Settings.

7.2 Time Setting Modes

The eWeLink app provides three flexible time setting modes:

  • Timing Mode: Set a specific time for an action to occur (e.g., turn on living room lights at 18:00 before work at night).
  • Countdown Mode: Set a duration after which an action will occur (e.g., turn off bedroom lights after 20 minutes after sleeping).
  • Cycle Timing Mode: Program recurring on/off periods (e.g., 6:00-9:00 for morning routines).
Three time setting modes: Timing, Countdown, Cycle Timing
Figure 11: Visual representation of Timing, Countdown, and Cycle Timing modes.

7.3 Voice Control

The ATS is compatible with popular voice assistants, allowing you to control your devices with simple voice commands.

  • Supported Platforms: Google Assistant, Amazon Alexa.
  • Example Command: "Alexa/Google, Open it in 10 minutes."
Voice control with Alexa and Google Home
Figure 12: Voice control integration with Google Assistant and Amazon Alexa.

7.4 Reset Key for WiFi Changes

If you need to change your WiFi network or switch to a different mobile phone for control, you must click the reset button on the device to reconnect it to the eWeLink App. Failure to do so will prevent connection.

Reset key location for WiFi changes
Figure 13: Location of the reset key for re-pairing with the eWeLink App.

8. Maintenance

The EARU EAATS-A Automatic Transfer Switch is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure optimal performance and longevity.

  • Visual Inspection: Regularly inspect the device for any signs of physical damage, loose connections, or overheating.
  • Cleanliness: Keep the device and its surroundings clean and free from dust and debris to prevent obstruction of ventilation and potential electrical issues.
  • Connection Integrity: Periodically check all wiring connections to ensure they are secure. Loose connections can lead to poor performance or safety hazards.
  • Functionality Test: Occasionally test the automatic transfer function by simulating a power outage (if safe and feasible) to ensure it switches correctly.
  • Software Updates: Keep the eWeLink app updated to the latest version to benefit from new features, improvements, and security patches.

Industrial Silver Contact

The device utilizes industrial silver contacts to improve its lifespan and ensure reliable switching over time.

9. Troubleshooting

  • Device not responding to app:
    • Check if the device is powered on and the WiFi indicator is active.
    • Ensure your smartphone is connected to a 2.4GHz WiFi network.
    • Verify that the eWeLink app is updated to the latest version.
    • If you recently changed your WiFi network or phone, press the reset key on the device and re-pair it with the app.
    • Check your router settings to ensure no firewalls or restrictions are blocking the device.
  • Automatic transfer not working:
    • Verify that both the main and standby power sources are correctly wired and functional.
    • Ensure the ATS is set to 'Auto' mode.
    • Check for any visible damage to the switch mechanism.
    • Consult a qualified electrician if the issue persists.
  • Device frequently disconnects from WiFi:
    • Ensure the device is within range of your WiFi router.
    • Minimize interference from other 2.4GHz devices.
    • Consider repositioning your router or the ATS for better signal strength.
  • Power indicator lights not working:
    • Check the power supply to the device.
    • If the device is functioning but indicators are off, there might be an internal fault. Contact support.

10. User Tips

  • Regular Testing: Periodically test your ATS by simulating a power outage to ensure it functions correctly when needed.
  • App Familiarity: Spend some time exploring all the features within the eWeLink app, especially the scheduling and timer functions, to maximize convenience.
  • Secure WiFi: Always use a strong, secure password for your 2.4GHz WiFi network to protect your smart devices.
  • Professional Installation: For complex setups or if you are unsure about electrical wiring, it is highly recommended to consult a qualified electrician for installation.
  • Passive Signal Output: Utilize the passive signal output feature by connecting it to signal lights for easy observation of the power source status, especially if the ATS is installed inside a cabinet.

11. Warranty and Support

For detailed warranty information and technical support, please refer to the official user manual PDF or contact EARU customer service.

A comprehensive user manual is available for download: User manual (PDF)

© 2024 EARU Electric. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.