Product Overview
The SAIFULI SFL-809 is a wire curtain infrared detector designed for home security alarm systems. It features a beautiful and robust outer shell, a dual infrared sensor, and MCU processing control for reliable detection. Advanced technologies such as auto temperature compensation, super anti-white light, and digital signal processing are integrated to reduce environmental disturbance and false alarms, ensuring product reliability.
This detector is ideal for creating an invisible curtain-like detection zone, protecting specific areas like windows, doors, or hallways.
Installation and Setup
Proper installation is crucial for optimal performance. Please follow these steps carefully:
- Mounting Location: Nail the bracket onto the wall using screws. The ideal installation height is approximately 2.2 meters. Ensure there are no obstructions directly in front of the lens that could interfere with detection.
- Wiring: Connect the detector to your alarm system using the provided wires.
- Red: +12VDC (Power Positive)
- Black: -12VDC (Power Negative)
- Green: Signal Output
- Yellow: Tamper Output
- Internal Configuration (Jumpers): The detector features jumpers for customizing its behavior.
- JP1 LED Switch: Controls the LED indicator.
- JP3 NC/NO Signal Jumper: Selects between Normally Closed (NC) or Normally Open (NO) signal output.
- Power-Up: After connecting to a DC 12V power source, the detector will undergo a 50-second pre-heating and self-check period. During this time, the LED light will flash. Once complete, the detector will enter normal working condition.
Operating Instructions
Once installed and powered, the SFL-809 detector operates as follows:
- Detection: When a person (or an animal weighing more than 11kg) moves within its detection range, the LED indicator will illuminate.
- LED Indicator: The LED can be optionally turned on or off via the JP1 jumper. This setting does not affect the detector's functionality.
- Signal Output: The alarm output signal can be configured as Normally Closed (NC) or Normally Open (NO) using the JP3 jumper, depending on your alarm system's requirements.
- Pulse Count: The pulse count feature is optional and can be adjusted to suit different environmental conditions, helping to prevent false alarms.
Maintenance
To ensure the longevity and optimal performance of your SFL-809 detector, follow these maintenance guidelines:
- Cleaning: If the detector's sensitivity needs to be restored due to dust or dirt on the lens, first cut off the power supply. Then, gently wipe the sensor lens surface with a soft, dry cloth. Reconnect power only after the surface is completely dry.
- Avoid Harsh Environments: Do not install or operate the detector in environments with rapidly changing temperatures or strong air currents (e.g., near electronic fans, refrigerators, ovens, or heat vents), as this can affect its performance and lead to false alarms.
Troubleshooting
If you encounter issues with your SFL-809 detector, consider the following:
- False Alarms: Ensure the installation height is correct (around 2.2m) and that there are no objects causing rapid temperature changes or air movement within the detection zone.
- No Detection: Verify that the detector is powered correctly (DC 9-16V) and that the wiring is secure. Check if the sensor lens is clean and unobstructed.
- LED Behavior: If the LED is not behaving as expected, check the JP1 LED switch setting. Remember that the LED status does not affect the detection functionality.
- General Precaution: This product is a security aid. While it helps prevent and control incidents, it should be used correctly and supplemented with other security measures to strengthen overall precaution.
Specifications
| Feature | Specification |
|---|---|
| Brand Name | SAIFULI |
| Model Number | SFL-809 |
| Working Voltage | DC 9-16V |
| Working Current | Below 25mA |
| Working Temperature | -10°C to 50°C |
| Installation Method | Wall Mounted |
| Installation Height | 2.2M (more or less) |
| Detection Distance | Max 8M |
| Detection Angle | 15° |
| Alarm Output | NC/NO Optional (DC28V 0.15A) |
| Tamper Output | DC28V 0.15A |
| Anti-Remove Switch | NC |
| Sensor Type | Japan Nicera Dual Element PIR Sensor |
| Features | Anti-burnt cover, SMT design, High RFI/EMI immunity, Tripe pulse Optional, Auto temperature compensation, Sensor CPU processing |
User Tips
- For optimal performance, ensure the detector is installed in a location free from direct sunlight, heating/cooling vents, or moving objects that could trigger false alarms.
- Regularly check the wiring connections to ensure they are secure and free from corrosion.
- Consider testing the detector periodically to confirm it is functioning correctly with your alarm system.
Warranty and Support
For any warranty claims or technical support, please contact your retailer or the SAIFULI customer service. Keep your purchase receipt as proof of purchase.