1. Important Safety Instructions
Please read through all the labels on the battery and this user guide before the first use.
- When connecting batteries in series or parallel, read all the precautions about how to connect first, or you may damage the batteries.
- Keep the battery away from rain, splashes, and any wet locations.
- DO NOT short circuit the battery.
- DO NOT reverse polarity connection.
- DO NOT expose the battery to fire, heat sources, or direct sunlight.
- DO NOT dismantle or modify the battery yourself.
- DO NOT drop, crush, shake, strike, or penetrate the battery.
- Please use the specified charger to charge batteries.
- Our batteries are assembled using waterproof glue. If you want to disassemble the batteries yourself, please ask the customer service team for directions on how to disassemble the batteries. But keep in mind that once the battery is disassembled, it cannot be restored to its original state of being.
2. Setup and Connection
2.1 Battery Connection Precautions
- All battery interconnect cables should be of the same wire gauge (AWG) and length, and come from the same brand. Inconsistent impedance can lead to unbalanced charge and discharge performance.
- Connect your batteries one by one in series (up to 4 batteries) or in parallel (up to 4 batteries). Secure all cable connections between the cable lugs and terminals.
2.2 Cable Sizing
When determining the cable size (AWG) for your system, consider the size of the electrical load and the distance between the load and your batteries.
Cables for Controller to Battery
| Solar Input Current | Wire Cross Section Area (mm²) | Wire AWG |
|---|---|---|
| 5A | 1.5 | 15 |
| 10A | 2.5 | 13 |
| 20A | 5 | 10 |
| 30A | 8 | 8 |
| 40A | 10 | 7 |
| 60A | 12 | 6 |
Cables for Inverter to Battery
| Cable Size | Copper Conductor Diameter (inches) | Maximum Amperage |
|---|---|---|
| 6 AWG | 0.20 | 115 |
| 4 AWG | 0.23 | 150 |
| 2 AWG | 0.30 | 205 |
| 1/0 AWG | 0.37 | 285 |
| 2/0 AWG | 0.43 | 325 |
| 4/0 AWG | 0.56 | 440 |
2.3 Initial Preparation
- For optimal performance, fully charge all batteries before connecting them.
- Ensure all batteries connected have the same voltage, capacity (Ah), and are the same type (Lithium Iron Phosphate (LiFePO4)).
- It is recommended to use batteries from the same brand for connection due to potential variations in built-in Battery Management Systems (BMS).
3. Operating Instructions
3.1 General Operation
The DATOUBOSS LiFePO4 battery is designed for deep cycle applications, providing reliable power for various needs. It features a Smart BMS for comprehensive protection.
3.2 Powering Appliances
When using the battery with an inverter to power AC appliances, be aware of the appliance's rated and peak power requirements. Some appliances, especially those with motors like air conditioners or water pumps, can have peak power demands up to 3 times their rated power. Ensure your inverter and battery bank can handle these peak loads.
4. Maintenance and Storage
4.1 Storage Guidelines
- To store your battery, keep it at least 30%-50% charged.
- It is recommended to charge the battery every 6 months when not in use to prevent over-discharge.
- Store the battery within the recommended temperature ranges: -4°F~113°F / -20°C~45°C (for 1-3 months) or -4°F~68°F / -20°C~20°C (for 1 year).
4.2 Temperature Considerations
- Charging Temperature: 32°F ~ 113°F (0°C ~ 45°C).
- Discharge Temperature: 14°F ~ 140°F (-10°C ~ 60°C).
- The battery is designed to cope effectively with extreme temperature variations, operating continuously from -4°F to 150°F.
5. Troubleshooting
5.1 Common Issues and Solutions
- Battery not recharging immediately after full discharge: If the battery is fully discharged at a continuous rate, it may not immediately recharge at half capacity. This can trigger high-temperature charging protection. Allow the battery to rest or cool down before attempting to recharge.
- Battery received at 0V or unable to activate: If the battery arrives at 0V or cannot be activated, it may indicate a deep discharge state. Contact customer support for specific activation instructions or warranty claims. Avoid deep discharge by adhering to recommended storage and usage guidelines.
6. Specifications
| Feature | Specification |
|---|---|
| Model | DT12V300Ah |
| Item Type | Car Batteries (Deep Cycle) |
| Voltage | 12 V |
| Capacity | 3840Wh ±10% |
| Charging Voltage | 14.4 ± 0.2V |
| Charge Current | Max 100A |
| Rated Discharge Current | 200A |
| Maximum Discharge Current | 240A |
| Charging Temperature | 32°F ~ 113°F (0°C ~ 45°C) |
| Discharge Temperature | 14°F ~ 140°F (-10°C ~ 60°C) |
| Discharge Depth | ≥80% |
| Series and Parallel Connection | 4P4S (up to 4 in series, up to 4 in parallel) |
| Battery Management | Integrated 200A BMS |
| BMS Protections | Overcurrent, Over-charge, Over-discharge, Short Circuit, Overload, Reverse Charge Prevention |
| Shell Material | ABS |
| Terminal Material | Brass (M8 Terminal Bolts) |
| Terminal Conductivity | ≥98% |
| Battery Average Life | 8000+ Cycles |
| Lifetime | 10 Years |
| Weight | 61.1 LBS (approx. 27.7 kg) |
| Dimensions (L x W x H) | 50cm (20in) x 25cm (10in) x 22cm (9in) |
7. Warranty and Support
7.1 Warranty Information
- LiFePO4 batteries are covered by a 3-year limited warranty from the original purchase date.
- If you encounter any issues during usage, please feel free to contact us.
- We only provide after-sales service for products sold by us or retailers and distributors authorized by us. If you have purchased your unit through other channels, please contact your seller for more information about the return and warranty.
7.2 Contact Information
- Email: Manager@xdatou.com
- Website: www.xdatou.com
- Phone/Wechat/Whatsapp/LINE: +8613783531376
8. User Tips
- When using with solar panels and an MPPT charge controller, ensure the MPPT settings are correctly configured for LiFePO4 batteries to optimize charging efficiency and battery lifespan.
- For high-power applications like running refrigerators or other large appliances, verify that your inverter's continuous and peak power ratings are sufficient for the combined load.
- Always check the battery's voltage upon receipt and before initial use. If the battery is at 0V, follow the seller's instructions for activation or contact support immediately to prevent potential damage.
9. Statement of Compliance
9.1 Disclaimer
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.