1. Product Overview

The HLK-LD6002C is a 60G FMCW (Frequency Modulated Continuous Wave) human falling detection sensor module developed by Hi-Link. It is based on the ADT6101P chip and integrates a 57-64GHz RF transceiver system, 2T2R PCB microstrip antenna, 1MB flash memory, a radar signal processing unit, and an ARM® Cortex®-M3 kernel. This module utilizes FMCW signal processing combined with advanced radar algorithms to accurately detect the presence and fall status of individuals in specific areas. It is ideal for ceiling installations in small, single-person environments such as bathrooms and toilets, providing reliable fall detection without being affected by environmental factors like temperature, humidity, noise, airflow, dust, or light.

Key Characteristics:

  • Radar detection based on FMCW frequency modulated continuous wave signal.
  • Large detection angle, supporting ±60° horizontal and ±60° elevation detection.
  • Dedicated personnel fall detection function.
  • Universal UART interface with communication protocol support.
  • Supports UART parameter adjustment for various scenario requirements.
  • Compact size: 25mm x 23mm, with pin header support for easy integration.
  • Unaffected by environmental factors such as temperature, humidity, noise, airflow, dust, or light.

Application Scenarios:

  • Health care and elder care (e.g., bathrooms, toilets).
  • Home security systems.
  • Smart home integration.

Video: Overview of Hi-Link Radar Modules, showcasing various radar module products.

2. Specifications

Functional Parameters:

Parameter ContentMinTypicalMaxUnit
Fall monitoring detection radius2m
Fall recognition accuracy90%

Electrical Characteristics:

Operational ParameterMinTypicalMaxUnit
Operating voltage (VCC)3.13.33.5V
Operating current (ICC)600mA
Operating temperature (TOP)-2085°C
Storage temperature (TST)-4085°C

RF Characteristics:

Operational ParameterMinTypicalMaxUnit
Operating Frequency5862GHz
Emission Power (Pout)12dBm
Antenna gain4dBi
Horizontal beam (-3dB)-6060°
Vertical beam (-3dB)-6060°

3. Hardware Description

Overall Dimensions:

The HLK-LD6002C module has compact dimensions of 25mm x 23mm. Detailed measurements and views are provided below.

HLK-LD6002C Module Dimensions

Image: Top, bottom, and side views of the HLK-LD6002C module with dimensions.

Pin Definition:

Pin Order NumberPin NameDescriptionRemarks
13V3POWER INPUT 3.3V
2GNDGND
3P19GPIO19Boot1
4TX2GPIO20
5AIO1Analog IO
6SCLOGPIO07
7TX0Connected to external serial port TX
8RX0Connected to external serial port RX

Module Peripheral Reference Design:

The following diagram illustrates a typical peripheral reference design for the HLK-LD6002C module, including power supply and host MCU connections.

Module Peripheral Reference Design

Image: Schematic showing the module's peripheral connections, including 3.3V power, GND, and UART TTL communication lines to a Host MCU.

Boot Configuration:

The module's boot behavior is determined by the configuration of pins BOOT1 (P19) and BOOT0 (P12).

BOOT1BOOT0Remarks
Configuration level01Flash starts within the module
Pin foot position numberPin8Pin12

Note: BOOT1 and BOOT0 module internals are pulled up. BOOT1 must be connected to a low level before the module starts for flash operation.

4. Installation and Setup

Typical Application Circuit:

The HLK-LD6002C module can directly output detected target information via the TX2 pin (high level for falling output, low level for unmanned falling). Additionally, UART0 outputs detailed detection results according to a specified protocol. The serial port data includes target falling information, allowing flexible integration into various application scenarios.

The module requires a 3.3V power supply with a capacity greater than 1A. The output voltage of the module's IO ports is 3.3V. The default serial port baud rate is 115200 with no parity.

Installation Mode and Induction Range:

For optimal performance, the module should be top-mounted at a hanging height of 2.2-3.0 meters. In this configuration, it provides a maximum induction radius of 2 meters.

Schematic Diagram of Top Installation for Fall Detection

Image: Schematic diagram illustrating the recommended top-mounted installation for the radar sensor, showing a height (H) of 2.2-3m and the detection cone for a person.

For more detailed installation and usage instructions, please refer to the official User Manual (PDF) available at HLK-LD6002C User Manual (PDF).

5. Operation and Configuration

GUI Visualization Tool Application:

The HLK-LD6002C module can be configured and monitored using a dedicated GUI visualization tool. Follow these steps:

  1. Device Connection:
    • Select the connected serial port in the GUI.
    • Set the Baud rate to 115200.
    • Click the '[Connect]' button. The module will then begin detection.
  2. Data Examining:
    • Select the '3D view' window within the GUI.
    • Drag and zoom the view to an appropriate size.
    • Observe the 'System Log' window for messages. Initially, no falls should be detected, and no abnormalities should be present.
    GUI Visualization Tool Interface

    Image: Screenshot of the GUI visualization tool showing the 3D view, system log, and control panel.

    When a fall event occurs, the 3D view will display 'Someone fell', and the System Log window will show the message 'Someone fell!'.

  3. Parameter Configuration:
    • Select the '[Fall]' button in the Option window to access the parameter configuration interface.
    • Mounting Height: Set this value according to the actual installation height.
    • Fall Threshold: This threshold defines the falling height based on the distance from the point cloud to the ground. It can be modified and debugged for specific usage scenarios.
    • Fall Sensitivity: This setting controls sensitivity; modification is generally not recommended.
    • Detection Area Rectangles (DetectRectXL, DetectRectXR, DetectRectZF, DetectRectZB): These parameters define the left, right, front, and back boundaries of the detection area.
    • After entering all required parameters, click the corresponding '[Apply]' button to save the configuration. Verify the parameters in the '[Fall]' window in the bottom left corner.
    • To read parameters currently set in the module, click '[Get All FallParas]'.
    • To obtain the current software version number, click the '[Get]' button in the 'Version' window.
    GUI Parameter Configuration Interface

    Image: Screenshot of the GUI showing parameter configuration options for fall detection, including mounting height, fall threshold, and detection area settings.

OTA Upgrade:

For instructions on how to perform an Over-The-Air (OTA) upgrade for the module firmware, please refer to the document "OTA Upgrade Tool User Manual V1.0".

6. Precautions

  • When the radar is operating, ensure there are no metal objects or other media blocking electromagnetic wave transmission in front of the antenna.
  • Different shell materials and distances from the module to the inner surface of the shell can affect the returned spectrum energy and parameter settings. Fine-tuning may be required. It is generally recommended that the module be 5-6mm away from the housing.
  • It is advisable to test the module with default settings first. If performance is not as expected, the shell structure can be sent to the manufacturer for testing and adjustment recommendations.
  • Using plastic for the shell is recommended, as the radar is highly sensitive. Materials with high attenuation may negatively impact detection performance.
  • Avoid installing the module near air conditioning outlets, fans, or other sources of strong airflow.
  • When installing and using multiple modules simultaneously, maintain a spacing greater than 0.5 meters between modules, and ensure their antennas are not facing each other directly.
  • Sensitivity can be adjusted based on the user scenario. Contact technical support if sensitivity adjustments are needed.
  • The detection distance of the radar module is influenced by the target's Radar Cross-Section (RCS) and environmental factors. Expect the effective detection distance to fluctuate within a certain range.
  • The radar module has strict power requirements: input voltage 3.1-3.5V, power ripple ≤ 50mV, and current ≥ 1A. If using a DCDC power supply, the switching frequency should be no less than 2MHz.
  • This product is designed for small area scenarios in bathrooms and single-person situations.
  • The product should be integrated with application scenarios to mitigate potential interference.

7. Radome Design Considerations

A radome is used to protect the radar antenna from environmental elements like rain, external factors, and wind. However, it can impact radar performance by causing dielectric loss and reflection loss, reducing effective antenna power, and distorting the antenna beam, which affects angle measurement. Therefore, proper radome design is crucial to minimize these effects and optimize radar performance.

Design Requirements:

  1. Material Selection: Choose radome materials with small dielectric constants and low loss angles to reduce their impact on radar performance, while ensuring firmness and low cost.

Dielectric Constant and Dissipation Factor of Common Materials:

MaterialDielectric Constant (εr)Dissipation Factor (tan δ)
Merlon2.90.012
ABS2.0-3.50.0050-0.019
PEEK3.20.0048
PTFE (Teflon®)2<0.0002
Plexiglass®2.60.009
Glass5.750.003
Pottery and porcelain9.80.0005
PE2.30.0003
PBT2.9-4.00.002
  1. The radome must have a smooth surface and uniform thickness.
  2. Antenna Thickness Design Requirements:

    The thickness (T) of the radome should satisfy the following formula:

    T = N * (c / (2f * √εr))

    Where:

    • T: Radome thickness
    • c: Speed of light (3 × 108 m/s)
    • f: Center frequency (e.g., 60 GHz for HLK-LD6002C)
    • εr: Material permittivity (Dielectric Constant, DK)
    • N: Integer (1, 2, 3...)

    For example, with f = 60 GHz, c / (2f) = 2.5 mm.

  3. Design requirements for the radar antenna from the inner surface of the enclosure.

8. User Tips

  • Ensure proper power supply (3.3V, >1A) for stable operation and accurate detection.
  • Avoid metal obstructions directly in front of the antenna to prevent interference and ensure optimal detection range.
  • When integrating multiple modules, maintain a minimum spacing of 0.5 meters between them to prevent cross-interference.
  • For ceiling installations, adhere to the recommended height of 2.2-3.0 meters for the best fall detection performance.
  • If experiencing unexpected behavior, first verify all wiring and power supply specifications before adjusting software parameters.

9. Support and Contact Information

For technical support, inquiries, or further details regarding the HLK-LD6002C module, please contact Shenzhen Hi-Link Electronic Co., Ltd.

Address: 17F, Building E, Xinghe WORLD, Minzhi Street, Long Hua district, Shenzhen 51813, Mainland China

Email: sales@hlktech.com

Website: www.hlktech.net

Shenzhen Hi-Link Electronic Co., Ltd. Company Profile

Image: Shenzhen Hi-Link Electronic Co., Ltd. company profile, factory, and exhibition photos.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.