Y&H XMC

Contents

Y&H XMC MPPT 140A Solar Charge Controller User Manual

Models: XMC-24V/140A, XMC-48V/140A

1. About This Manual

This manual describes the assembly, installation, operation, and troubleshooting of the Y&H XMC MPPT Solar Charge Controller. Please read this manual carefully before installations and operations. Keep this manual for future reference.

This manual provides safety and installation guidelines as well as information on tools and wiring.

2. Safety Instructions

⚠️ WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect DC terminals. Please refer to the INSTALLATION section of this manual for the details.
  10. One piece of 150A fuse is provided as over-current protection for the battery supply.
  11. NEVER cause DC input short circuited.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this charger back to local dealer or service center for maintenance.

3. Introduction

The Y&H XMC MPPT Solar Charge Controller is designed to efficiently manage power from solar panels to charge batteries. Its comprehensive LCD display offers user-configurable and easy-accessible button operation for settings such as battery charging current.

3.1 Features

  • Configurable battery charging current based on applications via LCD setting.
  • Over temperature protection.
  • Smart battery charger design for optimized battery performance.
  • Cold start function.
  • Advanced MPPT Technology with 98% tracking efficiency and 99% conversion efficiency.
  • Multiple protections: Heatsink over-temperature, Reverse Connection, Fan Sensitivity, Overvoltage, Short-Circuit, Overload Protection, and Lithium Battery Activation.
  • 4-Stage Charging (Bulk Charge, Constant Charging, Float Charge, Equalize Boost, Float Recharge) to improve battery life and prevent sulfation.
Advanced MPPT Technology and Battery Compatibility

Figure 3.1: Advanced MPPT Technology with 98% tracking efficiency and 99% conversion efficiency. Compatible with FLD, SLD, GEL, LI, AGM, and USER defined battery types.

Multiple Protection Features

Figure 3.2: Multiple protection features including heatsink over-temperature, reverse connection, fan sensitivity, overvoltage, short-circuit, and overload protection.

4-Stage Charging Cycle

Figure 3.3: Illustration of the 4-stage charging process (Bulk Charge, Constant Charging, Float Charge, Equalize Boost, Float Recharge) which prolongs battery lifecycle and reduces sulfation.

3.2 Basic System Architecture

The following illustration shows the basic application for this solar charger:

  • PV modules (Solar power)
  • Solar Charger
  • External Battery packs

3.3 Product Overview

The Y&H XMC MPPT Solar Charge Controller features a clear LCD display, fault and charging indicators, and function buttons for easy operation. Key components include PV input, ground connection, battery input, and an anti-dust kit.

Y&H MPPT Solar Charge Controller Product Overview

Figure 3.4: Product overview highlighting DC 48V battery voltage, 60-500Vdc Max PV Input, and MPPT 140A Charging Current.

140A MPPT Controller Features Comparison

Figure 3.5: Comparison of the 140A MPPT controller's features, including higher charging current, PV array power, open voltage, and terminal protection cover, compared to other controllers.

Play video
Watch video online

Video 3.1: A visual guide demonstrating the Y&H MPPT Solar Charge Controller 140A's appearance, wiring process, and battery setting adjustments.

4. Installation

4.1 Unpacking and Inspection

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:

  • The unit x 1
  • User manual x 1

4.2 Preparation

Before connecting all wirings, please take off the bottom cover by removing two screws.

4.3 Mounting the Unit

Consider the following points before selecting where to install:

  • Do not mount the charger on flammable construction materials.
  • Mount on a solid surface.
  • Install this charger at eye level in order to allow the LCD display to be read at all times.
  • For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
  • The recommended installation position is to be adhered to the wall vertically.
  • Be sure to keep other objects and surfaces as shown in diagrams to guarantee sufficient heat dissipation and to have enough space for removing wires.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two screws. It's recommended to use M6 screws.

4.4 Battery Connection

CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and charger. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in the table below as required fuse or breaker size.

WARNING! All wiring must be performed by a qualified personnel.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.

ModelWire SizeCable (mm²)Torque value (max)
24V/140A1 x 2AWG252 Nm
48V/140A1 x 2AWG252 Nm

Steps to implement battery connection:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram.
  4. Insert the battery wires flatly into battery connectors of the charger and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Make sure polarity at both the battery and the charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

4.5 PV Connection

CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the charger and PV modules.

WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable as below.

ModelWire SizeCable (mm²)Torque value (max)
24V/140A1 x 12AWG41.2 Nm
48V/140A1 x 12AWG41.2 Nm

PV Module Selection:

When selecting proper PV modules, please be sure to consider the parameters below:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the charger.
  2. Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
INVERTER MODEL24V/140A48V/140A
Max. PV Array Open Circuit Voltage500Vdc
PV Array MPPT Voltage Range60Vdc~500Vdc

Take a 250Wp PV module as an example. After considering the above two parameters, the recommended module configurations are listed in the table below:

Solar Panel Spec. (reference) - 250Wp, Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 13 pcs)Q'ty of panelsTotal input power
6 pcs in serial6 pcs1500W
8 pcs in serial8 pcs2000W
12 pcs in serial12 pcs3000W
13 pcs in serial13 pcs3250W
8 pieces in serial and 2 sets in parallel16 pcs4000W
10 pieces in serial and 2 sets in parallel20 pcs5000W
10 pieces in serial and 2 sets in parallel20 pcs6200W
12 pieces in serial and 2 sets in parallel24 pcs6500W

PV Module Wire Connection:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.

4.6 Final Assembly

After connecting all wirings, please put the bottom cover back by screwing the two screws.

5. Operation

5.1 Operation and Display Panel

The operation and display panel is on the front of the inverter. It includes two indicators, two function keys, and an LCD display, indicating the operating status and PV power information.

LED Indicator:

LED IndicatorMessages
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the charger
FlashingWarning condition occurs in the charger

Function Keys:

Function KeyDescription
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5.2 LCD Setting

After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press the "DOWN" button to select setting programs. Then, press "ENTER" button to confirm the selection or press "ENTER" button a second time to exit.

Setting Programs:

ProgramDescriptionSelectable option
00Back DefaultDisableOne-button restore setting options
Enable
01Maximum charging current:010A, 020A, 030A, 040A, 050A, 060A, 070A, 080A, 090A, 100A, 110A, 120A, 130A, 140A
02Battery typeAGM (default), Flooded, UserIf "User-Defined" is selected, battery charge voltage and low DC cut-off voltage can be set up in program 03 and 04.
03Bulk charging voltage (C.V voltage)24V default setting: 28.2V, 48V default setting: 56.4VIf self-defined is selected in program 02, this program can be set up. Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59V for 48V model. Increment of each click is 0.1V.
04Floating charging voltage (FV Voltage)24V default setting: 27.0V, 48V default setting: 54.0VIf self-defined is selected in program 02, this program can be set up. Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59V for 48V model. Increment of each click is 0.1V.
05Battery equalizationBattery equalization disable (default), Enable, DisableIf "Flooded" or "User-Defined" is selected in program 02, this program can be set up.
06Battery equalization voltage24V default setting: 29.2V, 48V default setting: 58.4VSetting range is from 25.0V to 29.5V for 24V model and 48.0V to 59.0V for 48V model. Increment of each click is 0.1V.
07Battery equalized time60min (default)Setting range is from 5min to 900min. Increment of each click is 5min.
08Battery equalized timeout120min (default)Setting range is from 5min to 900 min. Increment of each click is 5 min.
09Equalization interval30days (default)Setting range is from 0 to 90 days. Increment of each click is 1 day.
10Equalization activated immediatelyEnable, Disable (default)If equalization function is enabled in program 05, this program can be set up. If "Enable" is selected, it's to activate battery equalization immediately and the LCD main page will show "EQ". If "Disable" is selected, it will cancel equalization function until the next activated equalization time arrives based on program 09 setting. At this time, "EQ" will not be shown in the LCD main page.
11Year set2000-2099
12Month set01-12
13Day set01-31
14Hour set00-23
15Minute set00-59
16Clear EnergyEnable, Disable

5.3 Display Information

The LCD display information will be switched in turns by pressing the "DOWN" key. The selectable information is switched in the following order: PV voltages, PV current, PV power, battery voltage, charge current, date, power generation capacity, and version number.

Selectable informationLCD display
Version numberNEXT POWER CORP
BAT: 48V / 10.01
ModeStatus: Stand by
Chg: NO Charing
Status: Charging
Chg: CU Charing (Constant Current)
Status: Charging
Chg: FL Charing (Float)
BatteryStatus: Stand by
BAT:48.2V/ 1.4A
Status: Charging
BAT:53.6V/ 44.2A
PVStatus: Stand by
PV: 2.4V/ 0W
Status: Charging
PV:241.3V/2.45KW
Daily power generationStatus: Stand by
Etoday: 0KWh
Status: Charging
Etoday:0.374KWh
Monthly power generationStatus: Stand by
Emonth: 0KWh
Status: Charging
Emonth:3.630KWh
Gross generationStatus: Stand by
Etotal: 0KWh
Status: Charging
Etotal:6.447KWh
DateStatus: Stand by
2023/11/01 09:26
Status: Charging
2023/11/02 09:19

5.4 Battery Equalization Description

Equalization function is added into the charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.

How to Apply Equalization Function

You must enable the battery equalization function in monitoring LCD setting program 05 first. Then, you may apply this function in the device by either one of the following methods:

  1. Setting equalization interval in program 09.
  2. Active equalization immediately in program 10.

When to Equalize

In the float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter the Equalize stage.

Equalize charging time and timeout

In the Equalize stage, the controller will supply power to charge the battery as much as possible until the battery voltage raises to the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is arrived.

However, in the Equalize stage, when the battery equalized time is expired and the battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit

Every charger is already installed with an anti-dust kit from the factory. The charger will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust from your charger and increases product reliability in harsh environments.

Maintenance Steps:

  1. Please loosen the screw in a counterclockwise direction on the top of the charger.
  2. Then, the dustproof case can be removed, and the air filter foam can be taken out.
  3. Clean the air filter foam and dustproof case. After clearance, re-assemble the dust-kit back to the charger.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

7. Specifications

MPPT Solar Charging Mode

INVERTER MODEL24V48V
Max. PV Array Power4200W6500W
Nominal PV Voltage180Vdc280Vdc
PV Array MPPT Voltage Range60Vdc~450Vdc
Max PV Array Open Circuit Voltage500Vdc
Max Charging Current (AC charger plus solar charger)140Amp140Amp

Charging Curve

The charging curve illustrates the different stages of battery charging: Bulk (Constant Current), Absorption (Constant Voltage), and Maintenance (Floating), ensuring optimal battery health and performance.

8. Troubleshooting

ProblemLCD/LED/BuzzerExplanation / Possible causeWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer will be active for 3 seconds and then complete off.The battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. The battery voltage is far too low. (<1.4V/Cell)
2. Internal fuse tripped.
1. Contact repair center for replacing the fuse.
2. Re-charge battery.
3. Replace battery.
Buzzer beeps continuously and red LED is on.Fault code 02Internal temperature of charger component is over 70°C.Check whether the air flow of the unit is blocked or whether the ambient temperature is too high.
Fault code 03Battery is over-charged.Return to repair center.
The battery voltage is too high.Check if specifications and quantity of batteries are met.
Fault code 01Fan faultReplace the fan.
Fault code 06Bus voltage is too low.Restart the unit; if the error happens again, please return to repair center.

Fault Reference Code:

Fault CodeFault EventIcon on
01Fan is locked when charger is off.01
02Over temperature02
03Battery voltage is too high03
04Bus voltage is too high04
05Bus soft start failed05
06Bus voltage is too low06
07Current sensor failed07
08PV voltage is over limitation08

Warning Indicator:

Warning CodeWarning EventAudible AlarmIcon flashing
01Fan is locked when charger is on.None01
EQBattery equalizationNoneEQ
bPBattery is not connectedNonebP

9. User Tips

  • This controller is compatible with Lithium Iron Phosphate (LiFePO4) batteries. Ensure you select the correct battery type in the LCD settings (Program 02) for optimal charging.
  • For custom battery types, utilize the "User" setting in Program 02 to precisely configure charge and cut-off voltages in Programs 03 and 04.
  • Regularly check the LCD display for any fault codes or warning indicators to ensure the system is operating correctly. Refer to the Troubleshooting section for immediate actions.
  • Consider the environmental conditions for installation. Proper ventilation and adherence to temperature guidelines (0°C to 55°C) are crucial for the longevity and efficiency of the unit.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your local dealer or the service center where you purchased the product. Ensure you have your product model and serial number available when seeking support.

A detailed user manual in PDF format is available for download: Download User Manual (PDF)

11. Statement of Compliance

⚠️ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.