1. About This Manual
This manual describes the assembly, installation, operation, and troubleshooting of the Y&H XMC MPPT Solar Charge Controller. Please read this manual carefully before installations and operations. Keep this manual for future reference.
This manual provides safety and installation guidelines as well as information on tools and wiring.
2. Safety Instructions
⚠️ WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this charger, please follow required specifications to select appropriate cable size. It's very important to correctly operate this charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect DC terminals. Please refer to the INSTALLATION section of this manual for the details.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- NEVER cause DC input short circuited.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this charger back to local dealer or service center for maintenance.
3. Introduction
The Y&H XMC MPPT Solar Charge Controller is designed to efficiently manage power from solar panels to charge batteries. Its comprehensive LCD display offers user-configurable and easy-accessible button operation for settings such as battery charging current.
3.1 Features
- Configurable battery charging current based on applications via LCD setting.
- Over temperature protection.
- Smart battery charger design for optimized battery performance.
- Cold start function.
- Advanced MPPT Technology with 98% tracking efficiency and 99% conversion efficiency.
- Multiple protections: Heatsink over-temperature, Reverse Connection, Fan Sensitivity, Overvoltage, Short-Circuit, Overload Protection, and Lithium Battery Activation.
- 4-Stage Charging (Bulk Charge, Constant Charging, Float Charge, Equalize Boost, Float Recharge) to improve battery life and prevent sulfation.

Figure 3.1: Advanced MPPT Technology with 98% tracking efficiency and 99% conversion efficiency. Compatible with FLD, SLD, GEL, LI, AGM, and USER defined battery types.

Figure 3.2: Multiple protection features including heatsink over-temperature, reverse connection, fan sensitivity, overvoltage, short-circuit, and overload protection.

Figure 3.3: Illustration of the 4-stage charging process (Bulk Charge, Constant Charging, Float Charge, Equalize Boost, Float Recharge) which prolongs battery lifecycle and reduces sulfation.
3.2 Basic System Architecture
The following illustration shows the basic application for this solar charger:
- PV modules (Solar power)
- Solar Charger
- External Battery packs
3.3 Product Overview
The Y&H XMC MPPT Solar Charge Controller features a clear LCD display, fault and charging indicators, and function buttons for easy operation. Key components include PV input, ground connection, battery input, and an anti-dust kit.

Figure 3.4: Product overview highlighting DC 48V battery voltage, 60-500Vdc Max PV Input, and MPPT 140A Charging Current.

Figure 3.5: Comparison of the 140A MPPT controller's features, including higher charging current, PV array power, open voltage, and terminal protection cover, compared to other controllers.
Video 3.1: A visual guide demonstrating the Y&H MPPT Solar Charge Controller 140A's appearance, wiring process, and battery setting adjustments.
4. Installation
4.1 Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:
- The unit x 1
- User manual x 1
4.2 Preparation
Before connecting all wirings, please take off the bottom cover by removing two screws.
4.3 Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the charger on flammable construction materials.
- Mount on a solid surface.
- Install this charger at eye level in order to allow the LCD display to be read at all times.
- For proper air circulation to dissipate heat, allow a clearance of approximately 20 cm to the side and approximately 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in diagrams to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. It's recommended to use M6 screws.
4.4 Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and charger. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in the table below as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable as below.
Recommended battery cable size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 24V/140A | 1 x 2AWG | 25 | 2 Nm |
| 48V/140A | 1 x 2AWG | 25 | 2 Nm |
Steps to implement battery connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram.
- Insert the battery wires flatly into battery connectors of the charger and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Make sure polarity at both the battery and the charger is correctly connected and conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
4.5 PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between the charger and PV modules.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable as below.
Recommended PV cable size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 24V/140A | 1 x 12AWG | 4 | 1.2 Nm |
| 48V/140A | 1 x 12AWG | 4 | 1.2 Nm |
PV Module Selection:
When selecting proper PV modules, please be sure to consider the parameters below:
- Open circuit Voltage (Voc) of PV modules must not exceed the max. PV array open circuit voltage of the charger.
- Open circuit Voltage (Voc) of PV modules should be higher than the min. battery voltage.
| INVERTER MODEL | 24V/140A | 48V/140A |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 500Vdc | |
| PV Array MPPT Voltage Range | 60Vdc~500Vdc | |
Take a 250Wp PV module as an example. After considering the above two parameters, the recommended module configurations are listed in the table below:
| Solar Panel Spec. (reference) - 250Wp, Vmp: 30.1Vdc, Imp: 8.3A, Voc: 37.7Vdc, Isc: 8.4A, Cells: 60 | SOLAR INPUT (Min in serial: 6 pcs, max. in serial: 13 pcs) | Q'ty of panels | Total input power |
|---|---|---|---|
| 6 pcs in serial | 6 pcs | 1500W | |
| 8 pcs in serial | 8 pcs | 2000W | |
| 12 pcs in serial | 12 pcs | 3000W | |
| 13 pcs in serial | 13 pcs | 3250W | |
| 8 pieces in serial and 2 sets in parallel | 16 pcs | 4000W | |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 5000W | |
| 10 pieces in serial and 2 sets in parallel | 20 pcs | 6200W | |
| 12 pieces in serial and 2 sets in parallel | 24 pcs | 6500W |
PV Module Wire Connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Then, connect positive pole (+) of connection wire to positive pole (+) of PV input connector. Connect negative pole (-) of connection wire to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
4.6 Final Assembly
After connecting all wirings, please put the bottom cover back by screwing the two screws.
5. Operation
5.1 Operation and Display Panel
The operation and display panel is on the front of the inverter. It includes two indicators, two function keys, and an LCD display, indicating the operating status and PV power information.
LED Indicator:
| LED Indicator | Messages | ||
|---|---|---|---|
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the charger |
| Flashing | Warning condition occurs in the charger |
Function Keys:
| Function Key | Description |
|---|---|
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.2 LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Press the "DOWN" button to select setting programs. Then, press "ENTER" button to confirm the selection or press "ENTER" button a second time to exit.
Setting Programs:
| Program | Description | Selectable option | |
|---|---|---|---|
| 00 | Back Default | Disable | One-button restore setting options |
| Enable | |||
| 01 | Maximum charging current: | 010A, 020A, 030A, 040A, 050A, 060A, 070A, 080A, 090A, 100A, 110A, 120A, 130A, 140A | |
| 02 | Battery type | AGM (default), Flooded, User | If "User-Defined" is selected, battery charge voltage and low DC cut-off voltage can be set up in program 03 and 04. |
| 03 | Bulk charging voltage (C.V voltage) | 24V default setting: 28.2V, 48V default setting: 56.4V | If self-defined is selected in program 02, this program can be set up. Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59V for 48V model. Increment of each click is 0.1V. |
| 04 | Floating charging voltage (FV Voltage) | 24V default setting: 27.0V, 48V default setting: 54.0V | If self-defined is selected in program 02, this program can be set up. Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59V for 48V model. Increment of each click is 0.1V. |
| 05 | Battery equalization | Battery equalization disable (default), Enable, Disable | If "Flooded" or "User-Defined" is selected in program 02, this program can be set up. |
| 06 | Battery equalization voltage | 24V default setting: 29.2V, 48V default setting: 58.4V | Setting range is from 25.0V to 29.5V for 24V model and 48.0V to 59.0V for 48V model. Increment of each click is 0.1V. |
| 07 | Battery equalized time | 60min (default) | Setting range is from 5min to 900min. Increment of each click is 5min. |
| 08 | Battery equalized timeout | 120min (default) | Setting range is from 5min to 900 min. Increment of each click is 5 min. |
| 09 | Equalization interval | 30days (default) | Setting range is from 0 to 90 days. Increment of each click is 1 day. |
| 10 | Equalization activated immediately | Enable, Disable (default) | If equalization function is enabled in program 05, this program can be set up. If "Enable" is selected, it's to activate battery equalization immediately and the LCD main page will show "EQ". If "Disable" is selected, it will cancel equalization function until the next activated equalization time arrives based on program 09 setting. At this time, "EQ" will not be shown in the LCD main page. |
| 11 | Year set | 2000-2099 | |
| 12 | Month set | 01-12 | |
| 13 | Day set | 01-31 | |
| 14 | Hour set | 00-23 | |
| 15 | Minute set | 00-59 | |
| 16 | Clear Energy | Enable, Disable | |
5.3 Display Information
The LCD display information will be switched in turns by pressing the "DOWN" key. The selectable information is switched in the following order: PV voltages, PV current, PV power, battery voltage, charge current, date, power generation capacity, and version number.
| Selectable information | LCD display |
|---|---|
| Version number | NEXT POWER CORP BAT: 48V / 10.01 |
| Mode | Status: Stand by Chg: NO Charing |
| Status: Charging Chg: CU Charing (Constant Current) Status: Charging Chg: FL Charing (Float) | |
| Battery | Status: Stand by BAT:48.2V/ 1.4A |
| Status: Charging BAT:53.6V/ 44.2A | |
| PV | Status: Stand by PV: 2.4V/ 0W |
| Status: Charging PV:241.3V/2.45KW | |
| Daily power generation | Status: Stand by Etoday: 0KWh |
| Status: Charging Etoday:0.374KWh | |
| Monthly power generation | Status: Stand by Emonth: 0KWh |
| Status: Charging Emonth:3.630KWh | |
| Gross generation | Status: Stand by Etotal: 0KWh |
| Status: Charging Etotal:6.447KWh | |
| Date | Status: Stand by 2023/11/01 09:26 |
| Status: Charging 2023/11/02 09:19 |
5.4 Battery Equalization Description
Equalization function is added into the charge controller. It reverses the buildup of negative chemical effects like stratification, a condition where acid concentration is greater at the bottom of the battery than at the top. Equalization also helps to remove sulfate crystals that might have built up on the plates. If left unchecked, this condition, called sulfation, will reduce the overall capacity of the battery. Therefore, it's recommended to equalize the battery periodically.
How to Apply Equalization Function
You must enable the battery equalization function in monitoring LCD setting program 05 first. Then, you may apply this function in the device by either one of the following methods:
- Setting equalization interval in program 09.
- Active equalization immediately in program 10.
When to Equalize
In the float stage, when the setting equalization interval (battery equalization cycle) is arrived, or equalization is active immediately, the controller will start to enter the Equalize stage.
Equalize charging time and timeout
In the Equalize stage, the controller will supply power to charge the battery as much as possible until the battery voltage raises to the battery equalization voltage. Then, constant-voltage regulation is applied to maintain the battery voltage at the battery equalization voltage. The battery will remain in the Equalize stage until the setting battery equalized time is arrived.
However, in the Equalize stage, when the battery equalized time is expired and the battery voltage doesn't rise to the battery equalization voltage point, the charge controller will extend the battery equalized time until the battery voltage achieves the battery equalization voltage. If the battery voltage is still lower than the battery equalization voltage when the battery equalized timeout setting is over, the charge controller will stop equalization and return to the float stage.
6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit
Every charger is already installed with an anti-dust kit from the factory. The charger will automatically detect this kit and activate an internal thermal sensor to adjust the internal temperature. This kit also keeps dust from your charger and increases product reliability in harsh environments.
Maintenance Steps:
- Please loosen the screw in a counterclockwise direction on the top of the charger.
- Then, the dustproof case can be removed, and the air filter foam can be taken out.
- Clean the air filter foam and dustproof case. After clearance, re-assemble the dust-kit back to the charger.
NOTICE: The anti-dust kit should be cleaned from dust every one month.
7. Specifications
MPPT Solar Charging Mode
| INVERTER MODEL | 24V | 48V |
|---|---|---|
| Max. PV Array Power | 4200W | 6500W |
| Nominal PV Voltage | 180Vdc | 280Vdc |
| PV Array MPPT Voltage Range | 60Vdc~450Vdc | |
| Max PV Array Open Circuit Voltage | 500Vdc | |
| Max Charging Current (AC charger plus solar charger) | 140Amp | 140Amp |
Charging Curve
The charging curve illustrates the different stages of battery charging: Bulk (Constant Current), Absorption (Constant Voltage), and Maintenance (Floating), ensuring optimal battery health and performance.
8. Troubleshooting
| Problem | LCD/LED/Buzzer | Explanation / Possible cause | What to do |
|---|---|---|---|
| Unit shuts down automatically during startup process. | LCD/LEDs and buzzer will be active for 3 seconds and then complete off. | The battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on. | No indication. | 1. The battery voltage is far too low. (<1.4V/Cell) 2. Internal fuse tripped. | 1. Contact repair center for replacing the fuse. 2. Re-charge battery. 3. Replace battery. |
| Buzzer beeps continuously and red LED is on. | Fault code 02 | Internal temperature of charger component is over 70°C. | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| Fault code 03 | Battery is over-charged. | Return to repair center. | |
| The battery voltage is too high. | Check if specifications and quantity of batteries are met. | ||
| Fault code 01 | Fan fault | Replace the fan. | |
| Fault code 06 | Bus voltage is too low. | Restart the unit; if the error happens again, please return to repair center. |
Fault Reference Code:
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when charger is off. | 01 |
| 02 | Over temperature | 02 |
| 03 | Battery voltage is too high | 03 |
| 04 | Bus voltage is too high | 04 |
| 05 | Bus soft start failed | 05 |
| 06 | Bus voltage is too low | 06 |
| 07 | Current sensor failed | 07 |
| 08 | PV voltage is over limitation | 08 |
Warning Indicator:
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when charger is on. | None | 01 |
| EQ | Battery equalization | None | EQ |
| bP | Battery is not connected | None | bP |
9. User Tips
- This controller is compatible with Lithium Iron Phosphate (LiFePO4) batteries. Ensure you select the correct battery type in the LCD settings (Program 02) for optimal charging.
- For custom battery types, utilize the "User" setting in Program 02 to precisely configure charge and cut-off voltages in Programs 03 and 04.
- Regularly check the LCD display for any fault codes or warning indicators to ensure the system is operating correctly. Refer to the Troubleshooting section for immediate actions.
- Consider the environmental conditions for installation. Proper ventilation and adherence to temperature guidelines (0°C to 55°C) are crucial for the longevity and efficiency of the unit.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your local dealer or the service center where you purchased the product. Ensure you have your product model and serial number available when seeking support.
A detailed user manual in PDF format is available for download: Download User Manual (PDF)
11. Statement of Compliance
⚠️ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.