HIKVISION DS-KV8113-WME1(C) DS-KH6350-WTE1

Contents

HIKVISION Video Intercom Kit User Manual

Models: DS-KV8113-WME1(C) Outdoor Station & DS-KH6350-WTE1 Indoor Station

1. Introduction

This manual provides comprehensive instructions for the installation, configuration, and operation of your HIKVISION Video Intercom Kit. This kit includes the DS-KV8113-WME1(C) Outdoor Station and the DS-KH6350-WTE1 Indoor Station, designed to enhance your property's security and communication.

HIKVISION Video Intercom Kit Overview
Figure 1.1: HIKVISION Video Intercom Kit Overview
The kit includes an outdoor station, an indoor monitor, and supports Wi-Fi connectivity. It is capable of controlling two separate locks and comes with RFID key fobs for access. The specific models are DS-KV8113-WME1(C) and DS-KH6350-WTE1.

2. Safety Information

  • Ensure all power is disconnected before performing any installation or wiring.
  • Use only the specified power adapters or PoE (Power over Ethernet) equipment.
  • Avoid exposing the devices to extreme temperatures, humidity, or direct sunlight.
  • Handle components with care to prevent damage.

3. Package Contents

Verify that all items are present in your package:

  • DS-KV8113-WME1(C) Outdoor Station: 1 unit
  • Surface-mounted rain cover: 1 unit
  • DS-KH6350-WTE1 Indoor Station: 1 unit
  • RFID Key Fobs: 5 units
  • Installation accessories (screws, mounting plates, templates)
HIKVISION Video Intercom Kit Package Contents
Figure 3.1: Kit Package Contents
The image displays the DS-KV8113-WME1(C) outdoor station, the DS-KH6350-WTE1 indoor station, and five RFID key fobs included in the kit.

4. Product Overview

4.1 DS-KV8113-WME1(C) Outdoor Station

The outdoor station features a camera, microphone, loudspeaker, call button, and an RFID card reading area. It is designed for outdoor use with a protective shield.

Outdoor Station Rear View and Terminal Layout
Figure 4.1: Outdoor Station Rear View and Terminal Layout
The rear view shows the wiring terminals for LOCK, ALARM IN, RS485, POWER, and LAN connections. Dimensions are 174mm (length) x 91mm (width) x 29mm (depth).

4.2 DS-KH6350-WTE1 Indoor Station

The indoor station features a 7-inch TFT touch screen, microphone, loudspeaker, and network interface for communication and control.

5. Setup & Installation

5.1 Wiring Description (Outdoor Station)

Refer to the terminal diagram and table for proper wiring connections.

Table 5.1: Outdoor Station Terminal Description
NameInterfaceDescription
DOORNC2Door Lock Relay Output 2 (NC)
COM2Common Interface
NO2Door Lock Relay Output 2 (NO)
GNDGrounding
NC1Door Lock Relay Output 1 (NO)
COM1Common Interface
NO1Door Lock Relay Output 1 (NO)
ALARM INAI1Alarm Input 1 (Door Contact)
AI2Alarm Input 2 (Door Contact)
RS-485485+RS-485 Communication Interface
485-RS-485 Communication Interface
Power Input12 VDC12 VDC Input
GNDGrounding
NetworkLANNetwork Interface

Door Lock Wiring

The outdoor station supports controlling two door locks. NC1/COM1 is default for magnetic lock/electric bolt, NO1/COM1 for electric strike. For NO2/COM2/NC2, configure via iVMS-4200 client software.

Door Contact Wiring

Connect door contacts to AIN1 and AIN2 terminals. Configure 'Input' as 'Door Status' in I/O Settings.

Exit Button Wiring

Connect exit buttons to AIN3 and AIN4 terminals. Configure 'Input' as 'Exit Button' in I/O Settings.

Alarm Input Device Wiring

Connect alarm input devices to the appropriate terminals as per your system design.

5.2 Mounting the Outdoor Station

The outdoor station supports both surface and flush mounting. Recommended installation height (camera to ground) is 1.4m to 1.6m.

Outdoor Station Mounting Comparison
Figure 5.1: Outdoor Station Mounting Comparison
Surface Box Mounted: Depth 48mm, Height 189mm, Bottom Depth 25mm.
Flush Box Mounted: Front Depth 30mm, Recess 85mm, Recess Height 167mm, Bottom Depth 33mm, Front Depth 10mm, Total Height 186mm.

Surface Mounting (with/without Protective Shield)

  1. Stick the mounting template on the wall and drill screw holes.
  2. If using, align the protective shield with the mounting template.
  3. Secure the mounting plate to the wall with supplied screws.
  4. Secure the device onto the mounting plate with set screws.
  5. Fix the cover onto the device with a screw.

Flush Mounting (with/without Protective Shield)

  1. Stick the mounting template on the wall and drill the hole (suggested size: 169.4mm x 86.2mm x 33.5mm).
  2. Install the gang box into the hole with 4 screws.
  3. If using, align the protective shield with the gang box.
  4. Insert the device into the gang box and secure it with 4 supplied screws.
  5. Fix the cover onto the device with a screw.

5.3 Mounting the Indoor Station

The indoor station can be wall-mounted using a gang box or placed on a table with a table bracket.

Wall Mounting with Gang Box

  1. Chisel a hole in the wall (larger than the gang box).
  2. Insert the gang box (Type I or Type II) into the hole.
  3. Fix the wall mounting plate to the gang box with 2 screws.
  4. Hook the indoor station to the wall mounting plate by inserting the plate hooks into the slots on the rear panel until it locks.

Table Mounting with Table Bracket

  1. Place the table bracket on a desk.
  2. Route the cable through the cable hole to connect the indoor station.
  3. Hook the indoor station to the table bracket by inserting the bracket hooks into the slots on the rear panel until it locks.

5.4 Power and Network Connection

The outdoor station supports IEEE802.3af standard PoE or 12 VDC power. The indoor station supports 12 VDC power or standard PoE. Connect the LAN port of both devices to your network.

6. Configuration

6.1 Activate Device via Web (Outdoor Station)

Before use, the outdoor station must be activated by setting a strong password.

  1. Power on the device and connect it to the network. Default IP: 192.0.0.65.
  2. Open a web browser on a computer in the same subnet and enter the device's IP address.
  3. Create and confirm a strong password.
  4. Click OK to activate.

6.2 Access Device by Web Browsers

  1. Enter the device's IP address in your browser.
  2. Enter the username (default: admin) and the password you set during activation.
  3. Click Login.

6.3 Quick Configuration (Indoor Station)

  1. Activate Indoor Station: Power on, create and confirm a password.
  2. Set Password Reset Method: Choose reserved email or security questions.
  3. Network Parameters: Edit Local IP, Subnet Mask, Gateway, or enable DHCP.
  4. Configure Indoor Station: Select type, edit Floor/Room No., set Registration Password.
  5. Mobile Client Service (Optional): Enable if you wish to use the mobile app.
  6. Link Related Devices: The outdoor station should appear in the list if on the same LAN. Tap to link or enter its serial number. Configure its network parameters if needed.
  7. Tap Finish to save settings.

6.4 Communicate with Indoor Station

  1. Via web interface, go to Settings > Intercom > Press Button to Call.
  2. Edit the call number for each button on the outdoor station.
  3. Optionally, check 'Call Management Center' to set a central calling point.

6.5 Issue Card (RFID)

  1. Via web interface, go to User.
  2. Click Add > Add Card. Present the RFID card to the card reading area on the outdoor station.
  3. A confirmation window will pop up when issuing is complete.

7. Operating Instructions

7.1 Making and Receiving Calls

Video 7.1: HIKVISION Intercom System Demonstration
This video demonstrates key functionalities: making calls from the outdoor station to the indoor monitor and mobile app, unlocking doors via the app, simultaneous calls to multiple indoor units, motion detection recording playback, call recording playback, and controlling two electric locks via the mobile app during a call.

  • From Outdoor Station: A visitor presses the call button. The call rings on the configured indoor station(s) and simultaneously on the linked mobile app.
  • Answering Calls: On the indoor station, tap the green answer icon. On the mobile app, accept the call notification.
  • Intercom: Speak through the microphone and listen via the loudspeaker on both devices.

7.2 Door Unlocking

  • Via Indoor Station: During a call or live view, tap the unlock icon on the screen.
  • Via Mobile App: During a call or live view, tap the unlock icon on the app interface.
  • Via RFID Card: Present a pre-registered RFID key fob to the card reading area on the outdoor station.

7.3 Motion Detection Recording

The outdoor station can record video when motion is detected. These recordings can be reviewed on the indoor station.

  • To view: On the indoor station, navigate to the 'Video Record' or 'Notice' section and select the desired motion-triggered recording.

7.4 Call Recording

All intercom calls can be recorded. These recordings are stored and accessible from the indoor station.

  • To view: On the indoor station, navigate to the 'Video Record' or 'Notice' section and select the desired call recording.

7.5 Live View

Access the live camera feed from the outdoor station at any time via the indoor station or the mobile app.

  • On the indoor station, tap the 'Live View' icon.
  • On the mobile app, select the outdoor station to view its live feed.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device surfaces. Do not use harsh chemicals or abrasive cleaners.
  • Software Updates: Periodically check the manufacturer's website for firmware updates to ensure optimal performance and security.

9. Troubleshooting

  • No Power: Check all power connections, including PoE or 12VDC adapters. Ensure the power source is active.
  • No Video/Audio: Verify network connections (LAN/Wi-Fi). Ensure devices are properly configured and linked. Check camera lens for obstructions.
  • Door Not Unlocking: Check wiring to the lock. Ensure the lock type is correctly configured in the system settings. Verify RFID cards are properly issued.
  • Cannot Connect to Mobile App: Ensure the mobile client service is enabled on the indoor station and the device is connected to the internet. Check app permissions on your smartphone.

10. Specifications

10.1 DS-KV8113-WME1(C) Outdoor Station

Table 10.1: Outdoor Station Specifications
FeatureSpecification
Size174mm x 91mm x 29mm
PowerIEEE802.3af standard PoE, 12 VDC
Power (W)10 W
Camera Sensor TypeCMOS
Sensor Size1/3 Inch
Viewing AngleHorizontal: 124°; Vertical: 75°
Access ControlInductive Card (RFID)
WaterproofYes
InstallationSurface or Flush
Connection TypeWired
TechnologyDIGITAL
CertificationCE, FCC

10.2 DS-KH6350-WTE1 Indoor Station

Table 10.2: Indoor Station Specifications
FeatureSpecification
Screen Size7-inch
Display Screen TypeColor Touch Screen
Resolution1024 x 600
Operation MethodCapacitive touch screen
Answering ModeHands-free
System OSLinux
RAM / ROM128 MB / 32 MB
Audio Input1 built-in omnidirectional microphone
Audio Output1 built-in loudspeaker
Wi-Fi2.4 GHz, IEEE802.11b/g/n
Network Interface1 RJ-45 10/100 Mbps self-adaptive
Power Supply12 VDC, 1 A, IEEE802.3af Standard PoE
Power Consumption≤ 5 W
TF CardSupport TF card, up to 128 GB
Working Temperature-10°C to 50°C (14°F to 122°F)
Dimensions (W x H x D)175 mm x 113.5 mm x 21 mm

11. User Tips

  • For optimal performance, ensure a stable Wi-Fi or wired network connection for both indoor and outdoor units.
  • When setting up, ensure your computer is on the same subnet as the outdoor station for initial web configuration.
  • Consider using the Hik-Connect mobile app for remote access and convenience in managing your intercom system.

12. Warranty & Support

For warranty information, technical support, or service inquiries, please refer to the official HIKVISION website or contact your local distributor. Keep your purchase receipt for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.