AOKIN Inline Foot Cord Switch

Contents

AOKIN Inline Cord Switch Instruction Manual

1. Introduction

Thank you for purchasing the AOKIN Inline Cord Switch. This manual provides essential information for the safe and effective installation, operation, and maintenance of your new switches. Please read this manual thoroughly before use and retain it for future reference.

Front and back view of the black AOKIN inline cord switch

Figure 1: AOKIN Inline Cord Switch (Front and Back)

2. Safety Information

WARNING: Risk of Electric Shock. Installation should only be performed by qualified personnel or individuals with a thorough understanding of electrical wiring.

  • Always disconnect power to the circuit at the fuse box or circuit breaker before installing or servicing the switch.
  • Ensure all wire connections are secure and properly insulated to prevent short circuits and electric shock.
  • Do not exceed the specified voltage and current ratings (250V, 10A).
  • Ensure wires are properly secured within the switch housing and that no bare wires are exposed. While this switch design may not include a dedicated strain relief mechanism, it is critical to ensure the cable is firmly anchored externally to prevent tension on the internal connections.
  • Do not use in wet or damp locations.
  • Keep out of reach of children.
  • If you are unsure about any part of the installation process, consult a qualified electrician.

3. Package Contents

  • 4 x AOKIN Inline Cord Switches

4. Specifications

FeatureSpecification
TypeInline Cord Switch
ModelGW320
ColorBlack (with Indicator Neon) / White (with Indicator Neon)
MaterialPlastic, Metal
Rated VoltageAC 250V
Rated Current10A
Work Life10,000+ Times
Dimensions (L x W x H)72 x 27 x 21 mm (2.83" x 1.06" x 0.83")
Cable Hole Diameter7 mm (0.275")
Dimensions of the black inline switch

Figure 2: Switch Dimensions

Close-up of the switch casing showing GW320 10A250V marking

Figure 3: Model and Rating Markings

5. Setup and Installation

Follow these steps to install the inline cord switch:

  1. Disconnect Power: Ensure the power supply to the appliance or lamp cord is completely disconnected at the main circuit breaker or by unplugging the device.
  2. Open the Switch: Use a small screwdriver to carefully pry open the switch housing. It typically splits into two halves.
  3. Prepare the Cord: Cut the power cord at the desired location for the switch. Strip approximately 10-15mm (0.4-0.6 inches) of the outer insulation from both ends of the cut cord. Then, strip about 5-7mm (0.2-0.3 inches) of insulation from the individual Live (usually brown or black) and Neutral (usually blue or white) wires.
  4. Wire Connections: Refer to the wiring diagram below. This switch features screw terminals for secure connections. Connect the wires as follows:
    • Live (L) Wire: Connect the incoming Live wire to the terminal marked 'IN (L)' and the outgoing Live wire (to the load) to the terminal marked 'LOAD (L)'.
    • Neutral (N) Wire: Connect the incoming Neutral wire to the terminal marked 'IN (N)' and the outgoing Neutral wire (to the load) to the terminal marked 'LOAD (N)'.

    Important: Ensure that the Live and Neutral wires are connected to their respective terminals and are not crossed. The indicator light functionality depends on correct wiring.

  5. Secure Wires: Ensure all wire strands are fully inserted into the terminals and the screws are tightened firmly. Double-check that no loose strands are touching other terminals or the switch housing.
  6. Close the Switch: Carefully place the two halves of the switch housing back together, ensuring the wires are properly seated in their channels and not pinched. Snap or screw the housing shut.
  7. Test: Reconnect power to the circuit and test the switch functionality.
Internal view of the white switch showing terminals and wiring points

Figure 4: Internal View of Switch Terminals

Detailed wiring diagram for the inline switch showing three indicator light configurations

Figure 5: Wiring Diagram for Indicator Light Configurations

  • 1. As Switch Position Indicator Light: Light is always on when power is supplied, indicating the switch's location (not controlled by the switch).
  • 2. As Switch Status Indicator Light: Light turns on when the switch is ON and off when the switch is OFF (turns on/off with the switch).
  • 3. As Switch Status Indicator Light (Opposite Load State): Light is ON when the load is OFF, and OFF when the load is ON, indicating the switch's position in darkness.

6. Operating Instructions

The AOKIN Inline Cord Switch operates with a simple rocker mechanism:

  • Press the rocker switch to the 'ON' position to supply power to the connected appliance or lamp. The indicator light will illuminate according to your chosen wiring configuration.
  • Press the rocker switch to the 'OFF' position to cut power to the connected appliance or lamp. The indicator light will respond as per your wiring.
Hand holding the black inline switch, showing its ergonomic design

Figure 6: Operating the Switch

Inline switch integrated into a lamp cord on a floor, next to a table lamp

Figure 7: Switch in Use with a Lamp

7. Maintenance

  • Keep the switch clean and free from dust and debris. Use a dry cloth for cleaning.
  • Periodically inspect the switch and the connected cord for any signs of damage, fraying, or loose connections.
  • Do not attempt to repair a damaged switch; replace it with a new one.

8. Troubleshooting

ProblemPossible CauseSolution
Appliance/Lamp does not turn onNo power to the circuit; Incorrect wiring; Faulty appliance/lamp; Loose connectionsCheck power supply at the outlet/breaker; Verify wiring according to diagram (Figure 5); Test appliance/lamp separately; Re-tighten all wire connections (after disconnecting power).
Indicator light does not workIncorrect wiring for indicator; Faulty LED; No power to the circuitReview wiring diagram (Figure 5) for desired indicator behavior; If wired correctly, LED may be faulty (replace switch); Check power supply.

9. User Tips

  • The integrated LED indicator light is a convenient feature for easily locating the switch in the dark or confirming its status.
  • The screw terminals provide a secure and reliable connection for both Live and Neutral wires.
  • These switches are suitable for controlling currents up to 6 amps, making them ideal for most household lamps and small appliances.
  • Ensure the switch is properly closed and secured after wiring for safety and durability.

10. Declaration of Conformity

EC Declaration of Conformity

Company name: Shenzhen Weijin Weiye Technology Co.,Ltd.
Postal address: 2515, Block B, Building 1, Honglong Plaza, Baomin Road, Xixiang street, Bao 'an District, Shenzhen, Guangdong, China
Postcode: 518000
City: Shenzhen
Telephone number: +86 18038081374
E-Mail address: aokinae2000@aliyun.com

We declare that the DoC is issued under our sole responsibility and belongs to the following product:

Apparatus model/Product: Inline Cord Switch
Type: (Not specified)
Batch: (Not specified)
Serial number: (List of serial numbers omitted for brevity, refer to original document)

The object of the declaration described above is in conformity with the relevant Union harmonization legislation:

  • Low Voltage Directive (LVD) 2014/35/EU
  • EMC Directive 2014/30/EU

The following harmonized standards and technical specifications have been applied:

  • EN 55014, aregearg + A1:2009 + A2:2011

Signed for and on behalf of:
Place of issue: China
Date of issue: 2026.01.31
Name, function, signature: He Changan, General Manager

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.