1. General Information
The EMSZERO series utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
Advanced HI-EMT Technology:
The EMSZERO series employs advanced HI-EMT technology, utilizing high-energy focused electromagnetic waves to achieve intense muscle contractions, promoting muscle growth, and deep internal structural reshaping.
Touch-Controlled Display:
The touch-controlled display significantly simplifies device operation, allowing clear visibility of information from various positions. The brightness of the display is adjustable to accommodate different office lighting conditions. User-friendly, the screen guides you throughout the entire treatment process.
Real-time Monitoring and Guidance:
Throughout the treatment process, the display shows remaining treatment time, utilized channels and treatment methods, applied treatment types, attachments used, and other necessary information. This aids users in real-time monitoring of treatment progress and provides necessary guidance.
Upgradeability:
As your therapeutic needs evolve, you may wish to upgrade your equipment later on. The EMSZERO series offers flexible upgrade options to meet your future treatment requirements.
1.1 Indications for Use
EMSZERO is included to be used for:
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of fitter abdomen
- Strengthening, Toning and Firming of buttocks, thighs and calves
- Improvement of muscle tone and firmness, for strengthening muscles in arms
1.2 Operating Environment
The operating environment of the EMSZERO instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
2. Safety Precautions and Warnings
1.3 Patient Profile
This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.5 Contraindications
Do not use the device if any of the following conditions apply:
- Wounds on the skin (or avoid wounds when using)
- Patients with heart disease (such as those with arrhythmias), especially those with pacemakers
- Cancer patient
- Patients with infectious diseases
- Pregnant women, lactating women, menstrual period
- Major surgery patients, diabetic patients
- Having any metal in the body
- People with cerebrovascular disease (stroke patients)
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness
- Reduction in muscle fat
- Temporary muscle spasms
- Transient joint or muscle tendon pain
- Localized redness or skin flushing
Precautions before use:
- Do not use when feeling full; wait at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Start at the lowest intensity level, and then increase the intensity sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation. Try to eat after one hour after the operation.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
Front View of the Instrument:

Description: The front panel features a touch-controlled display screen, an EMS handle for treatment, and a power switch.
Rear View of the Instrument:

Description: The rear panel includes the connection port for the handle, the main power switch, the power plug input, and the fuse compartment.
Note: The handle can only be used with the original machine and cannot be used interchangeably.
3.2 Handle
The device comes with a specialized EMS handle designed for effective muscle stimulation and body sculpting. It connects securely to the main unit.
3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 1 | ![]() |
| 3 | 7*100CM Belt | 1 | |
| 4 | Power cable | 1 | |
| 5 | Manual | 1 copy |
4. Setup and Installation
1. Install the handle bracket
Use a screwdriver to install the handle bracket on top of the machine.
2. Handle film
Stick the protective film to the working part of the handle.
3. Installing the handle
Align the handle with the hole on the machine and fasten the clip. Lock the key ring to secure it.
4. Connect power
Connect one end of the power cord to the machine and the other end to a power socket.
5. Press on the back switch
Locate the main power switch on the rear panel of the device. Press it to turn the device on (light will illuminate) or off (light will turn off).
6. Press the front switch
Single-click the front power button to power on. Long press the front power button to power off.
5. Operating Instructions
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced. When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the 'o' position (ON).
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls
5.3.1 Setting the Therapy by Controls
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

Description: The interface includes navigation controls, channel selector, stop therapy button, start/pause therapy button, and settings for therapy parameters like intensity and time.
5.4 Unit Settings
The device offers various settings to customize your treatment and user experience:
- Mode 1 Operation: This mode typically operates at a frequency of 5-60Hz. Adjust handle operation time and intensity as needed.
- Mode 2 Operation: This mode typically operates at a frequency of 30-100Hz, offering 3 different periods of frequency for free adjustment. Adjust intensity, stage frequency, and time as needed.
- Language Settings: Select your preferred language for the interface.
- Sound Adjustment: Control the volume of device sounds.
- Brightness Adjustment: Adjust the screen brightness for optimal visibility.
- Set Date/Time: Configure the current date and time.
- System Adjustment: Access system-level settings.
- Technician Access: A password-protected section for technical adjustments.
Note: Adjust the corresponding intensity/stage frequency/time according to different customer needs. Click the start/pause work button to enter the operation. If the customer requests to pause, they can click the start/pause work button to pause the work, and after the work is completed, they can directly click the return key to return.
6. Therapy
6.1 Preparing the Therapy
- Communicate with patients
- Ensure good health
- Stay hydrated
- Wear appropriate clothing
- Avoid eating in large quantities
- Familiar with the treatment process
- Avoid drinking alcohol
6.2 Placing the Handle
Proper placement of the handle is crucial for effective treatment. Use the provided belt to secure the handle to the target area.






Description: Diagrams illustrating correct handle placement for various body areas including the belly, buttocks, arms, thighs, calves, and glutes.
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
6. Maintenance
7.1 Maintenance
7.1.1 Daily inspection
Regularly inspect instruments and components. Check if the power socket has a reliable connection to the ground. Check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
7.1.2 Cleaning
Instrument cleaning is performed on a regular basis to ensure sanitation and proper functioning of the equipment. The device housing can be wiped with a damp cloth, soapy water or a neutral detergent while the instrument is powered off.
7.1.3 Replacing the fuse
When replacing the fuse, to prevent electric shock, turn off the power and unplug the power plug.
7.2 Repair
After purchasing the instrument, fill in the warranty card and send it to the manufacturer or agent. Free warranty is provided for one year from the purchase date for product quality problems (warranty needs warranty card and purchase bill, limited to the instrument host, excluding accessories and consumables). After the warranty period, contact the manufacturer for paid after-sales service. Do not repair the machine without authorization; unauthorized unpacking voids the warranty.
8. Maintenance
8.1 Fuse Replacement
The fuse is set below the handle junction on the back of the machine. An additional spare fuse is included.
8.2 Cleaning of the Surface of the Device
The logo of the machine is painted by silk screen printing process. The rest of the parts are painted with a spray painting technique. Use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.
8.3 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
8.4 Transport and Storage
Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room, padded, with an ambient temperature of -10°C to 40°C and relative humidity not greater than 93%. Do not place near flammable, explosive, or corrosive gases.
Transportation: The instrument, in its packaging, is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, prevent severe vibration and shock, protect from moisture, and do not mix with flammable or corrosive substances. Specific requirements are specified in the order contract.
7. Troubleshooting
8.6 Common faults and troubleshooting methods
| Fault phenomenon | Causes | Exclusions and workarounds |
|---|---|---|
| Device not working | The power plug is not inserted into the socket Power switch not on Power fuse failure | Check the power Check the power switch Replace the fuse |
| Handle not working | Check the handle for loose | Reseat the handle |
8. Specifications
9. Technical Parameters
| Parameter | Value |
|---|---|
| Name | Emszero |
| Input power supply | AC110V-220V 50/60Hz |
| Output maximum power | 0-6500W |
| Frequency | 5-200HZ |
| Screen size | 8 inches |
| Machine color | White |
Additional Specifications:
- Material: ABS
- Item Type: Massage & Relaxation / Epilator
- Use: Bikini, Body, Face, Underarm
- Power Type: Electric
- Commodity Quality Certification: CE
9. User Tips
No specific user tips were available from the provided Q&A content.
10. Warranty and Support
10. Warranty Card
The machine can be replaced with a new one within 7 days from the date of purchase (with receipt) if in intact appearance. The main machine is guaranteed for one year (excluding fragile parts and other non-warranty scope or expired warranty period). Maintenance and updates are available, with appropriate charges. If the instrument needs repair within six months of purchase, the buyer bears return shipping costs, and the seller bears shipping-in costs. After six months, the buyer bears all shipping costs.
Free warranty service is not provided for user failures caused by personal reasons, including:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
11. Manufacturer