1. Product Overview
The Industrial Endoscope is a portable, high-quality, multifunctional digital video recording detection system. It features a full-color IPS screen and powerful video recording capabilities, allowing you to capture images (JPG) and record videos (AVI). Images can be captured at 2.0MP resolution and videos at 1080P HD, with files stored directly on a TF card.
This industrial endoscope is designed for non-destructive testing in complex industrial environments, such as inspecting automotive engine pipelines and mechanical parts. It enables inspection and observation in areas inaccessible to the human eye, facilitating diagnosis and processing without dismantling equipment.

Figure 1: Industrial Endoscope Overview
2. Safety Warnings and Precautions
- General Warning: Read all safety warnings and instructions before using this product. Failure to follow these warnings and instructions may result in product damage or personal injury.
- Disassembly: Do not disassemble the product yourself. To avoid malfunctions or damage, contact customer service for assistance.
- Temperature: Do not use the endoscope in high-temperature environments to prevent damage to the lens. The product's operating temperature range is -10°C to 50°C.
- Moisture/Mist: If the endoscope produces mist due to weather conditions, turn on the device and let it run for approximately 20 minutes until the image clears. Store the device in a dry place when not in use.
- Heat Generation: The lens may become warm during use, especially when the LED light is set to its brightest setting. This is normal and will not affect the operation or service life of the endoscope.
- Liquid and Debris: Prevent objects and liquids from entering the device's main unit, as liquids can damage electronic components and circuit boards. The camera lens and cable are waterproof (IP67/IP68 rated), but the main unit is not.
- Medical Use: Industrial endoscopes are not suitable for medical use.
- Legal Compliance: Camera products can only be used for purposes permissible under applicable laws and regulations. Misuse of the product for any illegal activities is strictly forbidden. Please comply with the applicable laws and regulations in your country/area.
3. Components and Controls

Figure 2: Endoscope Main Unit Controls
- Menu/Return Button: Press briefly to enter the menu interface.
- Up/Rotate Image Button: In menu, navigates up. In image interface, rotates image.
- Down/Rotate Image Button: In menu, navigates down. In image interface, rotates image.
- OK/Switch Button: In menu, confirms selection. In image interface, long press to switch between front and side cameras (for dual/triple lens models).
- Take Photo/Record Video Button: Short press to take a picture. Long press to start video recording, then short press again to stop.
- LED Lighting Control: Adjusts the brightness of the LED lights on the camera.
- Power On/Off Button: Turns the device on or off.
- TF Card Slot: For inserting a TF (MicroSD) card for storage.
- Work Indicator: Light indicating device status.
4. Setup
4.1 Charging the Device
Before first use, ensure the endoscope is fully charged. Connect the device to a power source using a compatible Type-C charging cable. A full charge typically takes approximately 2 hours.
4.2 TF Card Installation
The device supports TF (MicroSD) cards for storing images and videos. A TF card is not included and must be purchased separately.
- Ensure the endoscope is powered off before inserting the TF card.
- Locate the TF card slot (8) on the side of the device.
- Orient the TF card correctly, ensuring the front side is facing up.
- Gently insert the TF card into the slot until it clicks into place. Do not use excessive force to avoid damaging the card slot structure.
- To remove the TF card, gently push it inwards until it springs out, then pull it out.

Figure 3: TF Card Installation
5. Operation
5.1 Powering On/Off
Press the Power On/Off button (7) to turn the device on or off.
5.2 Menu Navigation
Briefly press the Menu/Return button (1) to enter the menu interface. Use the Up (2) and Down (3) buttons to navigate through the options. Press the OK button (4) to confirm a selection.
5.3 Adjusting LED Brightness
Use the LED Lighting Control (6) to adjust the brightness of the LED lights on the camera probe. This is crucial for illuminating dark inspection areas.

Figure 4: LED Brightness Adjustment
5.4 Capturing Images and Recording Videos
- Take a Picture: Short press the Take Photo/Record Video button (5).
- Record Video: Long press the Take Photo/Record Video button (5) to start recording. Short press it again to stop recording.
5.5 Switching Camera Lenses (Dual/Triple Lens Models Only)
For models equipped with dual or triple lenses, long press the OK button (4) in the image interface to switch between the front camera and side cameras.

Figure 5: Triple Lens Camera View
5.6 Image Rotation
In the image interface, use the Up (2) and Down (3) buttons to rotate the displayed image.
5.7 Live View Demonstration
Video 1: Demonstration of endoscope operation, including power on, light adjustment, and inspection in various environments like engine parts and pipes.
6. Maintenance
6.1 Cleaning
The camera lens and cable are waterproof (IP67/IP68). After use in wet or dirty environments, the probe can be rinsed with water. Ensure the main unit is kept dry and clean. Use a soft, dry cloth to wipe the screen and main unit. Do not use abrasive cleaners or solvents.
6.2 Storage
Store the endoscope in a dry place when not in use. Avoid extreme temperatures and direct sunlight. Keep the device and its accessories in a protective case to prevent damage.
6.3 Battery Care
To prolong battery life, charge the device regularly, even if not in frequent use. Avoid fully discharging the battery for extended periods.
6.4 TF Card Handling
Always power off the device before inserting or removing the TF card. Handle the TF card gently to prevent damage to the card or the device's card slot.
7. Troubleshooting
- Mist on Lens: If the endoscope image appears misty due to weather conditions, turn on the device and allow it to run for approximately 20 minutes. The heat generated by the device should help clear the mist.
- No Image/Display Issues: Ensure the camera cable is securely connected to the main unit. Check battery level and charge if necessary. If the issue persists, try restarting the device.
- Device Not Responding: If the device is unresponsive, try performing a hard reset (if applicable, refer to the full user manual for specific instructions). Ensure the battery is charged.
- General Malfunctions: For any other malfunctions or issues that cannot be resolved with the above steps, do not attempt to disassemble or repair the product yourself. Please contact customer service for professional assistance.
8. Specifications
| Feature | Specification |
|---|---|
| Model | T19 |
| Screen Type | 4.3-Inch Color IPS Display |
| Lens Diameter Options | 3.9mm, 5.5mm, 8mm, 12mm |
| Camera Type Options | Single Lens, Dual Lens, Triple Lens, Autofocus Lens |
| Camera Resolution | 1920*1080 (for Single/Dual/Triple Lens), 2560*1920 (for Autofocus Lens) |
| Video Resolution | 1280*720 |
| Horizontal Viewing Angle | 70° |
| Focal Length (Front Camera) | 5-10cm (Single/Dual/Triple Lens), 50-80mm (Autofocus Lens) |
| Focal Length (Side Camera) | 2-6cm (Single/Dual/Triple Lens), 20-50mm (Autofocus Lens) |
| Waterproof Level | IP67/IP68 (for lens cable only) |
| Battery | 3.7V, 2000mAh |
| Working Time | Up to 2-3 hours |
| Charging Time | Approx. 2 hours |
| LED Lights | Adjustable (e.g., 8MM triple lens: 8+2pcs, 8mm dual lens: 8+1pcs, 8mm: 8pcs, 5.5mm: 6pcs, 3.9mm: 6pcs, 12mm: 4pcs) |
| Cable Length Options | 1m, 2m, 3.5m, 5m, 10m, 15m (Rigid Cable) |
| Operating Temperature | -10°C ~ 50°C |
| Ports | Type-C charging port, TF memory card slot |
9. User Tips
- Choose the Right Lens: Consider the size of the area you need to inspect. Smaller diameters (3.9mm, 5.5mm) are ideal for very tight spaces, while larger diameters (8mm, 12mm) offer wider views. Dual or triple lenses provide multiple viewing angles without repositioning the probe.
- Optimal Focal Length: Pay attention to the recommended focal length for your specific lens type to achieve the clearest image. Adjust the distance between the camera and the object for best results.
- Cable Management: The semi-rigid cable can be shaped as needed. For longer cables, coil excess cable neatly to prevent tangles and make maneuvering easier.
- Lighting is Key: Always adjust the LED brightness to suit the environment. Too little light will result in dark images, while too much can cause glare.
- Regular Charging: Keep the device charged, especially before important inspections, to ensure uninterrupted operation.
10. Warranty and Support
For detailed warranty information and customer support, please refer to the official user manual PDF available at: User Manual (PDF).
In case of any malfunctions or issues not covered in this manual, please contact customer service for assistance. Do not attempt to repair the device yourself, as this may void your warranty and cause further damage.
Compliance: This product complies with FCC and RoHS standards. Made in China.