SHINEKNOT emergency light 118

Contents

SHINEKNOT Embedded Emergency Exit Light User Manual

Model: emergency light 118

Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SHINEKNOT Embedded Emergency Exit Light (Model: emergency light 118). This state-of-the-art LED exit indicator is designed to ensure safety and visibility in emergency situations, offering continuous illumination for 24 hours and an emergency duration of 180 minutes at AC85-265V. Its sleek design makes it suitable for both commercial and residential spaces, adhering to high standards of safety and compliance.

SHINEKNOT Embedded Emergency Exit Light, illuminated with a green running man symbol.
The SHINEKNOT Embedded Emergency Exit Light, showing the illuminated green exit symbol.

Setup and Installation

The SHINEKNOT Emergency Exit Light is designed for embedded installation. Please follow these steps carefully:

  1. Preparation: Ensure the power supply is turned off at the main circuit breaker before beginning installation.
  2. Mounting Location: Choose a suitable location for embedded installation, typically above an exit door or in a clear path to an emergency exit.
  3. Recess Opening: Create a recess in the ceiling or wall that accommodates the dimensions of the light fixture. The fixture dimensions are approximately 40cm (length of housing), 30cm (length of illuminated sign), and 20cm (height of illuminated sign).
  4. Diagram showing the dimensions of the LED emergency EXIT sign light: 40cm for the housing, 30cm for the illuminated sign length, and 20cm for the illuminated sign height.
    Product dimensions for recess preparation.
  5. Wiring: Connect the light fixture to the AC85-265V power supply. Refer to the wiring diagram on the product label for correct connections:
    • Brown wire: Live (L)
    • Blue wire: Neutral (N)
    • Yellow wire: Earth (E)
    Close-up of the product label showing wiring instructions and specifications. Wires are labeled L (Brown), N (Blue), E (Yellow). Specifications include Product name: LED emergency EXIT sign light, Input voltage: AC85-265V, Battery: NI-CD 1.2V 800mAh, Charge time: 24 hours, Emergency duration time: 120 mins.
    Wiring diagram and key specifications on the product label.
  6. Secure the Fixture: Insert the light fixture into the prepared recess. The embedded installation mechanism (spring clips) will secure the light in place.
    Close-up of the embedded installation mechanism, showing spring clips on the side of the light housing.
    Detail of the embedded installation spring clips.
  7. Power On: Once the installation is complete and secure, restore power at the main circuit breaker. The light should illuminate.

The light is constructed from Iron and Glass, featuring fireproof materials for enhanced safety.

Image showing the material composition of the emergency exit light: Iron + Glass, Fireproof material.
Material composition: Iron + Glass, Fireproof.

Operating Instructions

The SHINEKNOT Emergency Exit Light operates automatically once connected to a continuous power supply.

  • Continuous Illumination: When connected to AC power (AC85-265V), the LED exit sign will remain constantly on for 24 hours, providing clear guidance to exits.
  • Emergency Mode: In the event of a power outage, the built-in rechargeable Ni-CD 1.2V 800mAh battery will automatically activate, providing emergency illumination for up to 180 minutes (3 hours). The light is designed to provide consistent and bright light output during emergencies.
  • Battery Charging: The battery charges automatically when the light is connected to AC power. A full charge takes approximately 24 hours.
The emergency exit light is turned on, displaying a bright green running man symbol.
The emergency exit light in operation, showing the illuminated sign.

For a visual guide on the product, please watch the official product video:

Official product video demonstrating the SHINEKNOT Emergency Exit Light.

Maintenance

  • Cleaning: Regularly wipe the surface of the light with a soft, dry cloth to remove dust and debris. Do not use abrasive cleaners or solvents.
  • Battery Check: Periodically test the emergency function by temporarily cutting off the AC power supply to ensure the battery backup is working correctly and provides the specified emergency duration. This should be done at least once a month.
  • Battery Replacement: The Ni-CD battery has a limited lifespan. If the emergency duration significantly decreases or the light fails to operate in emergency mode after a full charge, the battery may need to be replaced by a qualified technician.
  • Inspection: Annually inspect the wiring and housing for any signs of damage, corrosion, or wear.

Troubleshooting

If you encounter issues with your emergency exit light, please refer to the following common troubleshooting steps:

  • Light Not Illuminating (AC Power):
    • Check the main power supply and circuit breaker to ensure power is on.
    • Verify that the wiring connections (Live, Neutral, Earth) are correct and secure.
    • Ensure the input voltage is within the specified AC85-265V range.
  • Light Not Illuminating in Emergency Mode (Power Outage):
    • Ensure the unit has been connected to AC power for at least 24 hours to allow the battery to fully charge.
    • The battery may be at the end of its lifespan and require replacement.
  • Emergency Duration is Shorter Than Expected:
    • The battery may not be fully charged; allow more time for charging.
    • The battery may be aging and losing capacity; consider battery replacement.

For complex issues or if troubleshooting steps do not resolve the problem, it is recommended to consult a qualified electrician.

Specifications

Feature Detail
Product Name LED Emergency EXIT Sign Light
Model Number emergency light 118
Brand SHINEKNOT
Light Source LED bulbs
Luminous Flux 249-2000 lumens
Input Voltage AC85-265V
Power Source Rechargeable battery
Battery Type Ni-CD 1.2V 800mAh
Battery Charge Time Approximately 24 hours
Emergency Duration 180 minutes (3 hours)
Continuous Illumination 24 hours (when connected to AC power)
Body Material Iron + Glass (Fireproof material) / ABS
Installation Type Embedded installation
Is Dimmable No
Is Bulbs Included Yes
Certifications VDE, UL, SAA, RoHS, pse, LVD, GS, FCC, EMC, CQC, CE, CCC
Usage Emergency exits in commercial and residential spaces
Product Dimensions (approx.) Housing Length: 40cm, Sign Length: 30cm, Sign Height: 20cm
Package Weight 1.3 kg

Note: Some specifications may vary slightly based on manufacturing batches.

User Tips

  • For optimal battery performance, ensure the unit is continuously connected to AC power to maintain a full charge.
  • Perform monthly tests of the emergency function by temporarily cutting off the AC power supply to confirm readiness and battery health.
  • Consider professional installation for best results and compliance with local electrical codes and safety regulations.
  • Keep the light's surface clean to ensure maximum visibility of the exit sign.

Warranty and Support

This SHINEKNOT Emergency Exit Light comes with a 7-year warranty, covering manufacturing defects and ensuring long-term reliability. For detailed warranty terms and conditions, please refer to the official product documentation.

For further assistance, technical support, or to access additional documentation, please refer to the User Manual (PDF) provided by the manufacturer. This PDF contains comprehensive guides and documents for your item.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.