Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your SHINEKNOT Embedded Emergency Exit Light (Model: emergency light 118). This state-of-the-art LED exit indicator is designed to ensure safety and visibility in emergency situations, offering continuous illumination for 24 hours and an emergency duration of 180 minutes at AC85-265V. Its sleek design makes it suitable for both commercial and residential spaces, adhering to high standards of safety and compliance.
Setup and Installation
The SHINEKNOT Emergency Exit Light is designed for embedded installation. Please follow these steps carefully:
- Preparation: Ensure the power supply is turned off at the main circuit breaker before beginning installation.
- Mounting Location: Choose a suitable location for embedded installation, typically above an exit door or in a clear path to an emergency exit.
- Recess Opening: Create a recess in the ceiling or wall that accommodates the dimensions of the light fixture. The fixture dimensions are approximately 40cm (length of housing), 30cm (length of illuminated sign), and 20cm (height of illuminated sign).
- Wiring: Connect the light fixture to the AC85-265V power supply. Refer to the wiring diagram on the product label for correct connections:
- Brown wire: Live (L)
- Blue wire: Neutral (N)
- Yellow wire: Earth (E)
Wiring diagram and key specifications on the product label. - Secure the Fixture: Insert the light fixture into the prepared recess. The embedded installation mechanism (spring clips) will secure the light in place.
Detail of the embedded installation spring clips. - Power On: Once the installation is complete and secure, restore power at the main circuit breaker. The light should illuminate.
The light is constructed from Iron and Glass, featuring fireproof materials for enhanced safety.
Operating Instructions
The SHINEKNOT Emergency Exit Light operates automatically once connected to a continuous power supply.
- Continuous Illumination: When connected to AC power (AC85-265V), the LED exit sign will remain constantly on for 24 hours, providing clear guidance to exits.
- Emergency Mode: In the event of a power outage, the built-in rechargeable Ni-CD 1.2V 800mAh battery will automatically activate, providing emergency illumination for up to 180 minutes (3 hours). The light is designed to provide consistent and bright light output during emergencies.
- Battery Charging: The battery charges automatically when the light is connected to AC power. A full charge takes approximately 24 hours.
For a visual guide on the product, please watch the official product video:
Maintenance
- Cleaning: Regularly wipe the surface of the light with a soft, dry cloth to remove dust and debris. Do not use abrasive cleaners or solvents.
- Battery Check: Periodically test the emergency function by temporarily cutting off the AC power supply to ensure the battery backup is working correctly and provides the specified emergency duration. This should be done at least once a month.
- Battery Replacement: The Ni-CD battery has a limited lifespan. If the emergency duration significantly decreases or the light fails to operate in emergency mode after a full charge, the battery may need to be replaced by a qualified technician.
- Inspection: Annually inspect the wiring and housing for any signs of damage, corrosion, or wear.
Troubleshooting
If you encounter issues with your emergency exit light, please refer to the following common troubleshooting steps:
- Light Not Illuminating (AC Power):
- Check the main power supply and circuit breaker to ensure power is on.
- Verify that the wiring connections (Live, Neutral, Earth) are correct and secure.
- Ensure the input voltage is within the specified AC85-265V range.
- Light Not Illuminating in Emergency Mode (Power Outage):
- Ensure the unit has been connected to AC power for at least 24 hours to allow the battery to fully charge.
- The battery may be at the end of its lifespan and require replacement.
- Emergency Duration is Shorter Than Expected:
- The battery may not be fully charged; allow more time for charging.
- The battery may be aging and losing capacity; consider battery replacement.
For complex issues or if troubleshooting steps do not resolve the problem, it is recommended to consult a qualified electrician.
Specifications
| Feature | Detail |
|---|---|
| Product Name | LED Emergency EXIT Sign Light |
| Model Number | emergency light 118 |
| Brand | SHINEKNOT |
| Light Source | LED bulbs |
| Luminous Flux | 249-2000 lumens |
| Input Voltage | AC85-265V |
| Power Source | Rechargeable battery |
| Battery Type | Ni-CD 1.2V 800mAh |
| Battery Charge Time | Approximately 24 hours |
| Emergency Duration | 180 minutes (3 hours) |
| Continuous Illumination | 24 hours (when connected to AC power) |
| Body Material | Iron + Glass (Fireproof material) / ABS |
| Installation Type | Embedded installation |
| Is Dimmable | No |
| Is Bulbs Included | Yes |
| Certifications | VDE, UL, SAA, RoHS, pse, LVD, GS, FCC, EMC, CQC, CE, CCC |
| Usage | Emergency exits in commercial and residential spaces |
| Product Dimensions (approx.) | Housing Length: 40cm, Sign Length: 30cm, Sign Height: 20cm |
| Package Weight | 1.3 kg |
Note: Some specifications may vary slightly based on manufacturing batches.
User Tips
- For optimal battery performance, ensure the unit is continuously connected to AC power to maintain a full charge.
- Perform monthly tests of the emergency function by temporarily cutting off the AC power supply to confirm readiness and battery health.
- Consider professional installation for best results and compliance with local electrical codes and safety regulations.
- Keep the light's surface clean to ensure maximum visibility of the exit sign.
Warranty and Support
This SHINEKNOT Emergency Exit Light comes with a 7-year warranty, covering manufacturing defects and ensuring long-term reliability. For detailed warranty terms and conditions, please refer to the official product documentation.
For further assistance, technical support, or to access additional documentation, please refer to the User Manual (PDF) provided by the manufacturer. This PDF contains comprehensive guides and documents for your item.