1. Overview

Welcome to the product! The SZBJ BM500A is a digital insulation resistance tester designed for measuring the insulating resistance of various materials and electrical equipment. It features switchable output test voltages of 250V, 500V, and 1000V, with a measurement range up to 1999MΩ.

This compact and portable device is ideal for maintenance, testing, and inspection of transformers, motors, cables, switches, and other electrical apparatuses, making it an essential tool for electrical and electronic testing.

SZBJ BM500A Digital Insulation Resistance Tester held in hand

Figure 1: SZBJ BM500A Digital Insulation Resistance Tester

2. Safety Information

WARNING: Important safety information. The user must read this!

DANGER: High-voltage electric shock is present!

The device is double-insulated for protection.

General Safety Rules:

  1. Read the operating instructions carefully before using the meter.
  2. It is strictly prohibited to use the meter before its rear cover is in place. Otherwise, it might cause an electric shock.
  3. Check and ensure the insulating layer of the test cable is in good condition without any breakage.
  4. To avoid electric shock, do not touch the test cable and the circuit under test when performing a test.
  5. Ensure one end of the test cable is securely inserted into the terminal.
  6. During testing, any range must not exceed its specified maximum input value.
  7. During testing, do not operate the switch knob to change a range to avoid damaging the meter.
  8. Before performing an insulation test, ensure the range selection switch has been set within an appropriate voltage range.
  9. Do not perform an insulating resistance test in a combustible environment. Sparks may cause an explosion.
  10. Stop using the meter if its case or test cable is broken during use and metal is exposed.
  11. When opening the rear cover for changing the battery, ensure the test cable has been removed from the test terminals and the range switch is set to the OFF position.
  12. Remove the battery when the meter will not be used for a long time.
  13. When the battery indicator is displayed, it is necessary to change the battery promptly to ensure measurement accuracy.

3. Setup

3.1. What's in the Box

Carefully unpack the contents and check for any damage. The package should contain:

  • 1 x SZBJ BM500A Digital Insulation Resistance Tester
  • 1 x Set of Test Leads (red and black)
  • 1 x User Manual (English)
  • 1 x Conformity Certificate/Warranty Card
Contents of the BM500A package: the tester, user manual, and test leads

Figure 2: Package Contents

3.2. Battery Installation

The BM500A requires a 9V battery (6F22 or NEDA 1604), which is typically not included. To install or replace the battery:

  1. Ensure the meter is turned OFF and all test leads are disconnected.
  2. Locate the battery compartment on the rear of the device.
  3. Open the battery cover.
  4. Insert a new 9V battery, observing the correct polarity.
  5. Close the battery cover securely.

3.3. Name and Function of Parts

Familiarize yourself with the components of your BM500A tester:

Diagram showing the name and function of parts of the BM500A tester

Figure 3: Parts Diagram

  1. LCD: Liquid Crystal Display for readings.
  2. Data-hold Switch (HOLD): Freezes the current reading on the display.
  3. Rotary Switch: Used to select functions and measurement ranges (OFF, 250V, 500V, 1000V, MΩ).
  4. L (LINE) Input Terminal: Connects to the line terminal of the object being tested.
  5. G Input Terminal: Shielded terminal for insulating resistance measurements.
  6. E (EARTH) Input Terminal: Connects to the EARTH terminal of the object being tested.
  7. TEST/STOP Key: Initiates and stops the insulation resistance measurement.
  8. Indicator Light of High Voltage: Illuminates when high voltage is output.

4. Operating Instructions

4.1. Insulating Resistance Test

DANGER: Improper operation can cause personal injury, meter failure, fire, or damage. Operate only after reading the instructions carefully.

  1. Preparation: Before testing, ensure the circuit to be tested is not electrified. Do not measure any live equipment or circuits. The object under test should be securely earthed. Short-circuit and discharge the test terminals of the object before connecting the meter.
  2. Connection of Test Terminals:
    • Insert the red test lead into the L (LINE) terminal socket.
    • Insert one end of the black test lead with a red test clamp into the E (EARTH) terminal socket.
    • Insert one end of the black test lead with a black test clamp into the G (SHIELD) terminal socket.
    • Ensure all connections are secure.
  3. Rated Voltage Selection: Turn the Rotary Switch to the desired test voltage (250V, 500V, or 1000V) for your insulation resistance test.
  4. Performing the Test:
    • Connect the free end of the test leads to the object being tested.
    • Press the TEST/STOP key. The red indicator light will turn on, indicating high voltage output. The actual high voltage value will be displayed on the meter.
    • The insulation resistance value will be displayed on the LCD.
    • Attention: Do not short-circuit the two test leads with high voltage output. Do not measure insulation resistance immediately after high voltage is output.
  5. Power Off:
    • After the test, release the TEST/STOP key. The red indicator light will turn off, indicating high-voltage output has been disconnected.
    • Turn the Rotary Switch to the OFF position. The LCD screen will turn off.
    • For capacitive loads, discharge any residual charge on the object before disconnecting the test leads.

5. Maintenance

WARNING: Always turn off the power and disconnect test leads before opening the meter case or battery cover to prevent electric shock.

  1. Battery Replacement: When the battery indicator is displayed on the meter, replace the 9V battery (6F22 or NEDA 1604) as described in Section 3.2.
  2. Cleaning: Keep the meter and test leads clean, dry, and undamaged. Use a clean, soft cloth or a mild cleaner to wipe the case. Do not use abrasive or organic solvents.
  3. Storage: Avoid mechanical damage, shock, and impact. Store the meter in a dry place, away from high temperatures and strong magnetic fields.

6. Troubleshooting

If the meter does not power on or function correctly, consider the following:

  • No Display/Meter Not Turning On: Check if the battery is correctly installed and has sufficient charge. Replace the battery if necessary.
  • Inaccurate Readings: Ensure test leads are properly connected and undamaged. Verify the correct voltage range is selected for the test.
  • High Voltage Indicator Not Lighting Up: Check battery level. If the issue persists, discontinue use and consult support.

For persistent issues, refer to the full user manual PDF or contact customer support.

7. Specifications

General Characteristics:

  • Auto Range: '1' displayed for overload.
  • Display Mode: Liquid Crystal Display (LCD); maximum display: 1999.
  • Sampling Rate: 2.5 times per second.
  • High Voltage Indication: LED light indicates high voltage output status.
  • Operating Environment: 0°C to 40°C, less than 75% RH.
  • Storage Environment: -10°C to 60°C, less than 80% RH.
  • Low Battery Indication: Battery symbol displayed.
  • Power Supply: 9V battery, 6F22 or NEDA 1604.
  • Dimensions: 69mm x 138mm x 31mm (with holster).
  • Weight: Approx. 170g (including battery).
Dimensions of the BM500A tester: 138mm length, 69mm width, 31mm thickness

Figure 4: Product Dimensions

Insulation Tester Technical Characteristics:

ParameterSpecification
Rated Voltage250V / 500V / 1000V
Open Circuit Voltage90% ~ 110% of rated voltage
Measurement Range0.001 ~ 1999MΩ
Minimum Resolution0.001 MΩ
Accuracy±(5% RDG + 5)
Measurement Resistance for Rated Voltage250V: about 500kΩ
500V: about 1.5MΩ
1000V: about 5MΩ
Short Circuit CurrentNot less than 1.5mA