Y&H SG(x)MD Series PV Smart Microinverter

Contents

Y&H SG(x)MD Series PV Smart Micro Inverter User Manual

Model: SG-600W, SG-700W, SG-800W, SG-1000W

1. Introduction

This manual provides essential information for the safe installation, operation, and maintenance of the Y&H SG(x)MD Series PV Smart Micro Inverter. Please read this manual thoroughly before operating the equipment. Failure to follow these instructions may result in serious injury, property damage, and/or electrical shock.

The Y&H Smart Micro Inverter is designed to convert direct current (DC) from solar photovoltaic (PV) panels into alternating current (AC) for grid-tie applications. It features Maximum Power Point Tracking (MPPT) for optimal energy harvesting and can be monitored via a cloud-based system.

2. Safety Information

WARNING! DANGER!

Read the user manual before operating this equipment. Failure to do so can result in serious injury, property damage, and/or electrical shock.

  • Use photovoltaic panel(s) ONLY to connect to this equipment.
  • This equipment is an ON-GRID Microinverter. To make it work properly, it must be connected to the power grid correctly, and the power grid must be working properly. When the power grid stops working, it will also stop generating.
  • Do NOT exceed PV panel(s) voltage over the inverter's maximum input voltage.
  • Do NOT exceed PV panel(s) power over the inverter's maximum input power.
  • DC voltage sources pass through this equipment. Each circuit must be individually disconnected before servicing.
  • Do NOT cover other items on this equipment.
  • Do NOT remove the lid. Servicing must be performed by qualified service personnel.
  • When the PV array is exposed to light, it supplies DC voltage to this equipment.
  • Install away from direct sunlight and direct rain exposure.

3. Product Overview

The Y&H Smart Micro Inverter is a compact and efficient device for solar energy systems. Below is a visual representation of the inverter and its key components.

Y&H Smart Micro Inverter
Figure 3.1: Y&H Smart Micro Inverter

This image shows the Y&H Smart Micro Inverter with its DC input connectors on both sides and an AC output cable. The device is silver-colored with 'Y&H SMART INVERTER' printed on top, along with a warning label. CE and VDE certifications are visible at the bottom right.

Y&H Smart Micro Inverter Components Diagram
Figure 3.2: Basic Structure and Components

This diagram labels the main components of the Smart Inverter: Status Indicator, 2.4G Antenna, Mounting, DC Input I & II to PV Module, AC Bus Cable to protect inverter, Screw, AC Bus Cable to next inverter/the Grid, and the WIFI Set/Reset Button. A warning label is also visible on the inverter's surface.

LED Display

  • Green light steady: Microinverter is generating power.
  • Red flash: Microinverter is in waiting mode.
  • Red light steady: Indicates a fault condition such as island protection, over-temperature, over/low AC voltage, over/low DC voltage, over/low AC frequency, or a general fault.

4. Specifications

Below are the detailed technical specifications for the Y&H SG(x)MD Series PV Smart Micro Inverter.

Y&H Smart Micro Inverter Dimensions
Figure 4.1: Inverter Dimensions

This image provides the dimensions of the Smart Inverter: 185mm x 180mm x 38.5mm (excluding connectors and cables). It also shows the length of the AC bus cable (1820mm) and the DC input cables (130mm and 240mm).

Parameter Table for SG(x)MD Series Micro Inverter
Product SeriesModelSG600MDSG700MDSG800MDSG1000MD
Input Data (DC, PV)Number of Input MC4 Connector2 sets
MPPT Voltage Range28V-55V
Operation Voltage Range20V-60V
Maximum Input Voltage60V
Startup Voltage20V
Maximum Input Power2*300W2*350W2*400W2*500W
Output Data (AC)Single-Phase Grid Type120V & 230V
Rated Output Power590W650W760W950W
Maximum Output Power600W700W800W1000W
Nominal Output Current @120VAC4.91A5.41A6.33A7.91A
Nominal Output Current @230VAC2.56A2.82A3.3A4.13A
Nominal Output Voltage120VAC / 230VAC
Default Output Voltage Range@120VAC: 80V-160V / @230VAC: 180V-280V
Nominal Output Frequency50Hz / 60Hz
EfficiencyPeak Efficiency95%
CEC Weighted Efficiency@120VAC: 92.5% / @230VAC: 93.5%
Nominal MPPT Efficiency99.9%
Night Power Consumption<700mW
Mechanical DataOperating Ambient Temperature Range-40°C to +65°C
Storage Temperature Range-40°C to +85°C
Dimensions (W x H x D)185mm x 180mm x 38.5mm (not include connectors and cable)
Weight1.5kg
Max Current of AC Bus Cable20A
Waterproof GradeIP65
Other FeaturesCommunicationWIFI With Cloud Monitoring
Transformer DesignHigh Frequency Transformers, Galvanically Isolated
Integrated GroundEquipment ground is provided by the PE in the AC cable. No additional ground is required.
Protection FunctionsIsolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc.
Design ComplianceCertificationCE etc.

5. Installation Procedures

Prior to installing the Microinverters, please verify that the utility voltage at the point of common grid connection matches the voltage rating on the Microinverter label.

5.1. Packing List

Ensure all items are present and undamaged before installation:

  • Micro inverter: 1 pc
  • Mounting screws: 1 set
  • Micro inverter User Manual: 1 pc
  • Cloud Monitoring User Manual: 1 pc
  • Antenna: 1 pc

5.2. Wiring Diagrams

The following diagrams illustrate various wiring configurations for the Y&H Smart Micro Inverter. Always ensure correct connections for safe and efficient operation.

Y&H Smart Micro Inverter Basic Wiring Diagram
Figure 5.1: Basic Wiring Diagram

This diagram shows a basic setup with two solar panels connected to the Smart Inverter. The inverter's AC output is connected to a power outlet. Text indicates that each MC4 branch cannot exceed 300W, with Vmp > 28V and Voc < 50V. The green line represents the ground connection.

Home Solar System with Microinverter
Figure 5.2: Home Solar System Integration

This diagram illustrates how the microinverter integrates into a home solar system. Solar panels are connected to the microinverter, which is then connected to the home's electrical panel. A Wi-Fi antenna on the inverter allows for monitoring, and household appliances are shown connected to the grid.

5.3. Step-by-Step Installation

  1. Attaching the Microinverters to the Racking:
    a. Mark the location of the Microinverter on the rack, with respect to the PV module junction box or any other obstructions.
    b. Mount one Microinverter at each of these locations using hardware recommended by your module racking vendor.
  2. Connecting the Microinverter AC bus cable one by one: Please do NOT exceed the Maximum Units per Branch.
  3. Connecting Microinverters to the PV Module: Please do NOT exceed PV panel(s) VOC over inverter max. input voltage.
  4. Tighten the Bus Cable End Cap: Tighten the Bus Cable End Cap at the end of the AC bus cable.
  5. Install the AC Branch Circuit Junction Box: Wire the conductors of the AC bus cable: L-BROWN, N-BLUE, G-GREEN&YELLOW. Connect the AC branch circuit junction box to the point of utility-grid interconnection.
  6. Double check all Microinverters: Ensure all Microinverters, connectors, and cables are correctly and well connected.
  7. Turn ON the AC circuit breaker: Turn ON the AC circuit breaker on each AC branch circuit of the Microinverter.
  8. Turn ON the main AC circuit breaker: Turn ON the main AC circuit breaker of the utility-grid. Your system will start producing power after a 30-second safety delay period.

5.4. AC Bus Cable and Connectors

The AC Bus Cable uses standard color coding for wiring:

  • P1 - L (BROWN)
  • P3 - N (BLUE)
  • P2 - G (GREEN&YELLOW)

For single micro inverter installations, you can cut off the left/right connector, or purchase an extra female/male connector/extension cable (pair with left/right connector) at extra cost.

6. Operation

Once installed and connected, the microinverter will automatically begin operation after the 30-second safety delay. The green LED indicator will blink and then remain steady when working correctly.

Operational Video Demonstration

Play video
Watch video online

This video demonstrates the connection process for the Y&H Smart Micro Inverter. It shows connecting the positive and negative terminals, connecting the AC output to the grid (simulated with a DC power supply for testing), and observing the green LED indicator light up and blink, signifying operation. The video also shows the peak output power reaching 600W. Finally, it illustrates the steps for connecting the inverter to a mobile application for monitoring, including opening the app, adding a device, connecting to Wi-Fi, and viewing real-time data like cumulative output, current output, DC voltage, DC current, AC voltage, and AC current.

7. Monitoring with App

The Y&H Smart Micro Inverter supports cloud monitoring via a dedicated mobile application. Follow these steps to connect your inverter to the app:

  1. Open the App: Launch the designated monitoring application on your smartphone or tablet.
  2. Click "Add": Navigate to the device management section and select the option to add a new device.
  3. Find and Add Products: The app will search for nearby devices. Select your "SMART INVERTER" from the list and tap to add it.
  4. Connect WIFI to the product: Follow the in-app instructions to connect the inverter to your local Wi-Fi network. You will need to enter your Wi-Fi password.
  5. Ready to use after configuration: Once successfully configured, you can view real-time data such as cumulative output, current output, DC voltage, DC current, AC voltage, and AC current.

8. Troubleshooting

If your microinverter is not operating as expected, refer to the LED display section for error indications. Common issues and their solutions include:

  • No Power Output: Check all DC and AC connections. Ensure the solar panels are receiving sufficient sunlight and producing adequate voltage. Verify that the utility grid is active.
  • Red Light Steady: This indicates a fault. Refer to the 'LED Display' section for possible causes (e.g., island protection, over-temperature, voltage/frequency issues). Disconnect and reconnect the inverter, then check if the fault persists. If so, contact qualified service personnel.
  • Inverter Not Connecting to App: Ensure your Wi-Fi network is active and the password is correct. Check the inverter's Wi-Fi status indicator. Try resetting the inverter's Wi-Fi module if available (refer to the 'WIFI Set/Reset Button' on the basic structure diagram).
  • Low Power Output: Check for shading on solar panels. Ensure panel specifications (Vmp, Voc, Max Power) are within the inverter's operating range. Clean solar panels if dirty.

9. Maintenance

The Y&H Smart Micro Inverter is designed for minimal maintenance. However, regular checks can ensure optimal performance and longevity:

  • Visual Inspection: Periodically inspect the inverter and all cables for any signs of damage, corrosion, or loose connections.
  • Cleaning: Ensure the inverter's cooling fins are free from dust and debris to maintain proper heat dissipation. Use a soft, dry cloth for cleaning. Do not use liquids or abrasive cleaners.
  • Panel Cleaning: Keep solar panels clean from dirt, dust, and leaves to maximize energy production.
  • Software Updates: Check the mobile application or manufacturer's website for any available firmware updates for the inverter.

Note: All servicing must be performed by qualified service personnel.

10. User Tips

Based on common user experiences and best practices for solar microinverters:

  • Optimal Panel Placement: Ensure your solar panels are positioned to receive maximum sunlight throughout the day, avoiding shadows from trees or buildings.
  • Monitor Performance Regularly: Use the mobile app to regularly check your system's performance. This helps in identifying any drops in power output early, which could indicate a problem with a panel or the inverter.
  • Secure Connections: Double-check all MC4 and AC connections during installation. Loose connections can lead to efficiency losses or safety hazards.
  • Ventilation: Although the inverter uses natural convection cooling, ensure it is installed in a location with adequate airflow to prevent overheating, especially in hot climates.
  • Consult the PDF Manual: For more in-depth information or specific troubleshooting steps, refer to the comprehensive user manual available in PDF format: Y&H Micro Inverter User Manual (PDF).

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your vendor or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.

The manufacturer offers an after-sales guarantee which includes determining the cause of product faults, providing free replacement parts, and replacing the product if necessary.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.