1. Introduction
The DIGITEN FL-308D G3/8" Water Flow Sensor is designed for precise measurement of liquid flow. It is primarily composed of a plastic valve body, a water flow rotor assembly, and a Hall sensor. This sensor is suitable for various applications requiring accurate flow detection, such as water heaters, coffee machines, water purifiers, drinking fountains, and beverage machines.
Key Features:
- Lightweight and flexible design, small in size, and easy to install.
- Internal impeller features stainless steel beads for enhanced wear resistance.
- Seal ring utilizes an upper and lower force structure to prevent leaks.
- Hall element is imported from Germany and encapsulated with potting glue to prevent water ingress and aging.
- All raw materials comply with ROSH testing standards.
- Integrated magnetic Hall effect sensor outputs an electrical pulse with each revolution.
- Hall effect sensor is sealed from the water pipe for safety and dryness.
2. Specifications
General Specifications:
| Parameter | Value |
|---|---|
| External Thread Diameter | G3/8" |
| Interior Diameter | 5.5mm |
| External Diameter | 9.5mm |
| Flow Range | 0.3-10 L/min |
| Frequency (F) | F = 23.6 * Q (L/min) |
| Pressure Range | ≤ 0.8 MPa |
| Working Voltage Range | DC 5-18 V |
| Max Rated Current | 15 mA (DC 5V) |
| Loading Capacity | ≤ 10 mA (DC 5V) |
| Working Temperature Range | ≤ 80°C |
| Humidity Range | 35%~90% RH (Frost-free state) |
| Accuracy (Flow-Pulse Output) | 0.5~10 L/min ± 3% |
| Output Pulse Duty Cycle | 50 ± 10% |
| Output Rise Time | 0.04 µS |
| Output Fall Time | 0.18 µS |
| Output Waveform | Square Wave, output pulse signal |
| Cable Length | 15cm |
| Material | Food Grade POM |
Dimensional Information:
The sensor features G3/8" quick-connect fittings. Key dimensions are approximately:
- Overall length: Approximately 60mm (from end to end of the quick connectors).
- Main body width: Approximately 28.35mm.
- Main body height: Approximately 21.95mm.
- Connector width: Approximately 36.42mm.
For detailed dimensional drawings, please refer to the official user manual (PDF).
Flow-Pulse Characteristic Reference:
The pulse frequency (Hz) is directly proportional to the flow rate (Q in L/min), with a formula of F = [21 * Q] ± 3%. Below is a reference table for various flow rates:
| Flow (L/min) | Pulses (Hz) | Error (±) | Min Value (Hz) | Max Value (Hz) |
|---|---|---|---|---|
| 1 | 21 | 1.020 | 20.58 | 21.42 |
| 2.1 | 44.1 | 1.021 | 43.218 | 44.982 |
| 2.2 | 46.2 | 1.022 | 45.276 | 47.124 |
| 2.3 | 48.3 | 1.023 | 47.334 | 49.266 |
| 2.4 | 50.4 | 1.024 | 49.392 | 51.408 |
| 2.5 | 52.5 | 1.025 | 51.45 | 53.55 |
| 2.6 | 54.6 | 1.026 | 53.508 | 55.692 |
| 2.7 | 56.7 | 1.027 | 55.566 | 57.834 |
| 2.8 | 58.8 | 1.028 | 57.624 | 59.976 |
| 2.9 | 60.9 | 1.029 | 59.682 | 62.118 |
| 3 | 63 | 1.030 | 61.74 | 64.26 |
| 3.1 | 65.1 | 1.031 | 63.798 | 66.402 |
| 3.2 | 67.2 | 1.032 | 65.856 | 68.544 |
| 3.3 | 69.3 | 1.033 | 67.914 | 70.686 |
| 3.4 | 71.4 | 1.034 | 69.972 | 72.828 |
| 3.5 | 73.5 | 1.035 | 72.03 | 74.97 |
| 3.6 | 75.6 | 1.036 | 74.088 | 77.112 |
| 3.7 | 77.7 | 1.037 | 76.146 | 79.254 |
| 3.8 | 79.8 | 1.038 | 78.204 | 81.396 |
| 3.9 | 81.9 | 1.039 | 80.262 | 83.538 |
| 4 | 84 | 1.040 | 82.32 | 85.68 |
| 4.1 | 86.1 | 1.041 | 84.378 | 87.822 |
| 4.2 | 88.2 | 1.042 | 86.436 | 89.964 |
| 4.3 | 90.3 | 1.043 | 88.494 | 92.106 |
| 4.4 | 92.4 | 1.044 | 90.552 | 94.248 |
| 4.5 | 94.5 | 1.045 | 92.61 | 96.39 |
| 4.6 | 96.6 | 1.046 | 94.668 | 98.532 |
| 4.7 | 98.7 | 1.047 | 96.726 | 100.674 |
| 4.8 | 100.8 | 1.048 | 98.784 | 102.816 |
| 4.9 | 102.9 | 1.049 | 100.842 | 104.958 |
| 5 | 105 | 1.050 | 102.9 | 107.1 |
3. Setup and Installation
Installation Guidelines:
- Install the sensor in accordance with the flow direction indicated on the product. Incorrect installation will result in no signal output.
- A filter screen must be installed at the inlet of the sensor to prevent particles and debris from entering and affecting performance.
- The sensor should be installed vertically, with a slope of no more than 5 degrees, to ensure accurate readings.
- The medium temperature should not exceed 120°C.
Wiring Instructions:
The sensor features a three-wire connection system:
- Red Wire: Connect to VCC (+) (Positive power supply).
- Black Wire: Connect to GND (Ground).
- Yellow Wire: Connect to Signal Output.
The Hall sensor outputs a pulse signal corresponding to the water flow. This signal is fed back to a controller, which then determines and regulates the water flow.
| Pin | Wire Color | Function |
|---|---|---|
| 1 | Red | VCC (+) |
| 2 | Yellow | Signal Output |
| 3 | Black | GND |
4. Operating Principle
The water flow sensor operates by detecting the rotation of an internal impeller. As water flows through the sensor, it causes the impeller to rotate. A magnetic rotor within the impeller assembly rotates, and a Hall sensor detects this rotation. The rotational speed of the magnetic rotor changes proportionally with the water flow rate.
The Hall sensor then generates a series of electrical pulses, with the frequency of these pulses directly corresponding to the water flow rate. This pulse signal is transmitted to a connected controller or microcontroller, which interprets the frequency to determine the precise volume and rate of water flowing through the sensor. The output pulse duty cycle is typically 50% ± 10%.
5. Maintenance and Care
- Prevent Contamination: Always ensure a filter screen is installed at the inlet to prevent debris from entering the sensor, which can impede the impeller's movement and affect accuracy.
- Temperature Limits: Do not expose the sensor to medium temperatures exceeding 120°C.
- Physical Handling: Avoid severe impact, chemical attack, throwing, or colliding the sensor. Such actions can damage the internal components and lead to malfunction.
- Durability: The sensor is designed for long-term use, tested for 300,000 cycles at 0.1 MPa water pressure (1 second on, 0.5 seconds off) without abnormality.
- Storage: Store the sensor in environments within -25°C to +80°C and 25% to 95% RH (non-condensing).
6. Troubleshooting
- No Signal Output:
- Check if the sensor is installed correctly according to the flow direction.
- Verify that the wiring (Red: VCC+, Black: GND, Yellow: Signal) is correct and secure.
- Ensure the power supply is within the DC 5-18V range.
- Inspect for blockages at the inlet; a clogged filter or debris can prevent impeller rotation.
- Inaccurate Readings:
- Confirm vertical installation with a slope of no more than 5 degrees.
- Check for any physical damage or deformation to the sensor body or impeller.
- Ensure the water pressure is within the specified range (≤ 0.8 MPa).
- Verify that the medium temperature is within the operating range (≤ 80°C).
- Leakage:
- Check all connections for proper sealing and tightness.
- Inspect the sensor body for cracks or damage.
7. User Tips
- This sensor is effective for measuring volume in water pump applications.
- Consider using appropriate connectors and sealing tape to ensure a watertight installation, especially in high-pressure systems.
- Regularly check the inlet filter for accumulation of debris to maintain optimal performance and prevent flow restrictions.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact DIGITEN Official Store directly. Keep your purchase records for any warranty claims.
You can also refer to the official user manual (PDF) for additional details and support information.