Sumry 4000W Off Grid Hybrid Inverter
Model: HGX 4KW | Brand: SUMRY
Front view of the Sumry HGX 4KW Hybrid Inverter, highlighting 4000W/120VAC, 24VDC, 55-280VDC MPPT voltage range, and 50Hz/60Hz automatic recognition.
1. Introduction
1.1. Purpose
This manual describes the assembly, installation, operation, and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference.
1.2. Scope
This manual provides safety and installation guidelines as well as information on tools and wiring.
1.3. Features
- Off grid solar inverter
- Under Battery Mode, AC voltage can be adjusted to 100VAC, 110VAC, and 120VAC.
- Utility power, battery, and PV power complement each other.
- Pure sine wave solar inverter.
- Unique glass top cover design with 6.25-inch LCD display and touchable buttons.
- Built-in 150A MPPT (Max PV 7200W) solar charger.
- High PV input range from 55V-450Vdc.
- Smart battery charger design for optimized battery performance.
- Configurable AC/Battery input priority via LCD setting.
- Auto restart while PV is recovering.
- Over-load, over temperature, and output short circuit protection.
- Cold restart function.
- Built-in lithium battery automatic activation.
- Communication with RS232/RS485.
- WiFi monitoring function (optional).
- Anti-dust kit for harsh environment (optional).
- Restore default settings with one click.
Illustration of the inverter powering various household appliances like a fridge, air conditioner, washing machine, and microwave oven, demonstrating its 4000W capacity.
1.4. Basic System Architecture
The inverter/charger can be used in a basic application with the following devices to form a complete running system:
- Generator or Utility.
- PV modules (option).
Consult with your system integrator for other possible system architectures depending on your requirements. This inverter can power all kinds of appliances in home or office environments, including motor-type appliances such as tube light, fan, refrigerator, and air conditioner.
Diagram showing the inverter connected to 24V batteries (GEL, FLD, LI, USE), indicating 140A PV Max and 110A AC Max.
Image depicting the inverter in an outdoor setting, emphasizing its battery-less support feature, allowing power from PV array without a connected battery.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION - Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
- GROUNDING INSTRUCTIONS - This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.
3. Setup (Installation)
Watch the installation video for a visual guide:
Video demonstrating the installation process of the hybrid inverter, including wiring connections for battery, AC, PV, and communication.
3.1. Unpacking and Inspection
Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items:
- The unit x 1
- User manual x 1
3.2. Preparation
Before connecting all wirings, please take off the bottom cover by removing two screws.
3.3. Mounting the Unit
Consider the following points before selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level in order to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces clear (as shown in the diagram in the PDF manual) to guarantee sufficient heat dissipation and to have enough space for removing wires.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws.
3.4. Battery Connection
CAUTION: For safety operation and regulation compliance, it's requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it's still requested to have over-current protection installed. Please refer to typical amperage in the table below as required fuse or breaker size.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of injury, please use the proper recommended cable and terminal size as below.
Please follow below steps to implement battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal size.
- Connect all battery packs as units requires.
NOTE: Please only use sealed lead acid battery or sealed GEL/AGM lead-acid battery or lithium battery.
- Insert the ring terminal of battery cable flatly into the battery connector of the inverter and make sure the bolts are tightened with a torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charger is correctly connected and ring terminals are tightly screwed to the battery terminals.
| Model | Typical Amperage | Battery Capacity | Wire Size | Cable mm² | Ring Terminal Dimensions | Torque Value | ||
|---|---|---|---|---|---|---|---|---|
| D (mm) | L (mm) | M (mm) | ||||||
| 3.0KW 24V | 110A | 100AH 200AH |
1*4AWG | 22 | 8 | 44 | 18.2 | 2~3 Nm |
| 4.0KW 24V | 150A | 200AH | 1*2AWG | 35 | 8 | 44 | 18.2 | 2~3 Nm |
WARNING: Shock Hazard - Installation must be performed with care due to high battery voltage in series.
CAUTION!! Do not place anything between the flat part of the inverter terminal and the ring terminal. Otherwise, overheating may occur.
CAUTION!! Do not apply anti-oxidant substance on the terminals before terminals are connected tightly.
CAUTION!! Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).
3.5. AC Input/Output Connection
CAUTION!! Before connecting to AC input power source, please install a separate AC breaker between inverter and AC input power source. This will ensure the inverter can be securely disconnected during maintenance and fully protected from over current of AC input. The recommended spec of AC breaker is for 32A for 3.0KW, 40A for 4.0KW.
CAUTION!! There are two terminal blocks with "INPUT" and "OUTPUT" markings. Please do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for AC input connection. To reduce risk of injury, please use the proper recommended cable size as below.
Suggested cable requirement for AC wires:
| Model | Gauge | Torque Value |
|---|---|---|
| 3.0KW | 10 AWG | 1.2~1.6 Nm |
| 4.0KW | 8 AWG | 1.4~1.6 Nm |
Please follow below steps to implement AC input/output connection:
- Before making AC input/output connection, be sure to open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. And shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten the terminal screws.
L—LINE (brown or black)
N—Neutral (blue or white)
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
4. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws. Be sure to connect PE protective conductor (Ground, green) first.
L—LINE (brown or black)
N—Neutral (blue or white)
5. Make sure the wires are securely connected.
CAUTION: Important - Be sure to connect AC wires with correct polarity. If L and N wires are connected reversely, it may cause utility short-circuited when these inverters are worked in parallel operation.
CAUTION: Appliances such as air conditioner are required at least 2~3 minutes to restart because it's required to have enough time to balance refrigerant gas inside of circuits. If a power shortage occurs and recovers in a short time, it will cause damage to your connected appliances. To prevent this kind of damage, please check manufacturer of air conditioner if it's equipped with time-delay function for installation. Otherwise, this inverter/charger will trigger an overload fault and cut off output to protect your appliance, but sometimes it still causes internal damage to the air conditioner.
3.6. PV Connection
CAUTION: Before connecting to PV modules, please install separately a DC circuit breaker between inverter and PV modules.
WARNING! All wiring must be performed by a qualified personnel.
WARNING! It's very important for system safety and efficient operation to use appropriate cable for PV module connection. To reduce risk of injury, please use the proper recommended cable size as below.
PV Module Selection:
When selecting proper PV modules, please be sure to consider below parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than min. PV Array MPPT Voltage range.
| INVERTER MODEL | 3.0KW | 4.0KW |
|---|---|---|
| Max. PV Array Open Circuit Voltage | 350Vdc | |
| PV Array MPPT Voltage Range | 55Vdc~350Vdc | |
Suggested cable requirement for PV wires:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.0KW/4.0KW | 1 x 12AWG | 4 | 1.2 Nm |
Please follow below steps to implement PV module connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Check correct polarity of connection cable from PV modules and PV input connectors. Then, connect positive pole (+) of connection cable to positive pole (+) of PV input connector. Connect negative pole (-) of connection cable to negative pole (-) of PV input connector.
- Make sure the wires are securely connected.
Close-up side view of the inverter's connection ports, clearly labeled for Battery input, AC output, RS485/RS232 communication port, AC input, and PV input.
3.7. Final Assembly
After connecting all wirings, please put the bottom cover back by screwing two screws.
4. Operating Instructions
4.1. Power ON/OFF
Once the unit has been properly installed and the batteries are connected well, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2. Operation and Display Panel
The operation and display panel is on the front panel of the inverter. It includes three indicators, four function keys, and an LCD display, indicating the operating status and input/output power information.
LED Indicators:
- AC-INV (Green): Solid On (Output is powered by utility in Line mode), Flashing (Output is powered by battery or PV in battery mode).
- CHG (Green): Solid On (Battery is fully charged), Flashing (Battery is charging).
- FAULT (Red): Solid On (Fault occurs in the inverter), Flashing (Warning condition occurs in the inverter).
Function Keys:
- ESC: To exit setting mode.
- UP: To go to previous selection.
- DOWN: To go to next selection.
- ENTER: To confirm the selection in setting mode or enter setting mode.
4.3. LCD Display Icons
The LCD display provides various information through icons and numerical values. Key information includes:
- Input Source Information: AC (utility input), PV (solar input).
- Input/Battery/Temp: Input voltage, input frequency, PV voltage, battery voltage, and charger current.
- Configuration Program and Fault Information: Setting programs, warning codes, and fault codes.
- Output Information: Output voltage, output frequency, load percent, load in VA, load in Watt, and discharging current.
- Battery Information: Left side flashing bar and battery icon indicate battery level (0-20%, 20-40%, 40-60%, 80-100%) in battery mode and charging status in line mode.
- Load Information: Overload indicator, load level (0-24%, 25-50%, 50-75%, 75-100%).
- Mode Operation Information: Unit connects to mains, unit connects to PV panel, load supplied by utility power (BYPASS), utility charger circuit working, DC/AC inverter circuit working.
- Mute Operation: Indicates unit alarm is disabled.
4.4. LCD Setting
After pressing and holding the ENTER button for 3 seconds, the unit will enter setting mode. Use "UP" or "DOWN" buttons to select setting programs, then "ENTER" to confirm or "ESC" to exit.
Key settings include:
- Output source priority (Program 01): Configure whether solar energy, battery, or utility is prioritized for loads.
- Maximum charging current (Program 02): Set total charging current for solar and utility chargers.
- AC input voltage range (Program 03): Select between Appliance (90-140VAC) or UPS (90-140VAC) modes.
- Power saving mode enable/disable (Program 04): Enable to turn off output when load is low, disable to keep output on.
- Battery type (Program 05): Select battery type (AGM, Flooded, Lithium, User-Defined). For Lithium batteries, select "LIB" or "Lib-485".
- Auto restart (Program 06, 07): Enable/disable auto restart after overload or over temperature.
- Output voltage (Program 08): Set AC output voltage (100V, 110V, 120V).
- Output frequency (Program 09): Set output frequency (50Hz/60Hz).
- Maximum utility charging current (Program 11): Set the maximum current drawn from utility for charging.
- Setting voltage point back to utility source (Program 12): For SBU priority, defines the battery voltage threshold to switch back to utility.
- Setting voltage point back to battery mode (Program 13): For SBU priority, defines the battery voltage threshold to switch back to battery.
- Low DC cut-off voltage (Program 29): Set the minimum DC voltage before the inverter cuts off output.
- Restore default settings (Program 30): Resets all settings to factory defaults.
- Battery equalization (Program 33-39): Settings for battery equalization voltage, time, and interval.
4.5. Lithium Battery Connection and Settings
If the inverter is matched with lithium batteries, only lithium batteries that have been matched with the BMS communication protocol are allowed to be used.
To implement lithium battery connection:
- Assemble battery ring terminal based on recommended battery cable and terminal specifications.
- Insert the ring terminal of battery cable flatly into battery connector of inverter and make sure the bolts are tightened with a torque of 2-3Nm. Make sure polarity at both the battery and the inverter/charger is correctly connected and ring terminals are tightly screwed to the battery terminals.
- Connect the RJ45 connector to the COMM port on the inverter.
- Connect the other end of the RJ45 plug to the battery communication port (RS485). Ensure that the battery signal cable RS485-A is connected to the RS485-A of the COMM port, and the battery signal cable RS485-B is connected to the RS485-B of the COMM port.
Note: If choosing lithium battery, make sure to connect the BMS communication cable between the battery and the inverter. You need to choose battery type as "Lib-485" mode in Program 5.
The pin of the inverter BMS interface is defined as shown in the PDF manual (Pin 1: RX, Pin 2: TX, Pin 3: VCC, Pin 4: VCC, Pin 5: RS485-A, Pin 6: RS485-B, Pin 7: GND, Pin 8: GND).
When the battery type is set to "Lib-485", the settings of Programs 12, 13, and 29 are automatically configured, and the default charging current is 0.5C. If communication fails, the inverter will cut off output.
4.6. Operating Mode Description
The inverter operates in various modes:
- Standby mode / Power saving mode: No output is supplied, but the unit can still charge batteries.
- Line Mode: Unit provides power from the mains and charges the battery. Can prioritize solar or battery if configured.
- Battery Mode: Unit provides output power from battery and PV power. PV energy can supply loads and charge batteries simultaneously, or power can come from battery only, or PV energy only.
4.7. Battery Equalization Description
Equalization reverses the buildup of negative chemical effects like stratification and removes sulfate crystals, which can reduce battery capacity. It's recommended to equalize batteries periodically.
To apply equalization:
- Enable battery equalization function in monitoring LCD setting program 33.
- Set equalization interval in program 37, or activate equalization immediately in program 39.
The PDF manual includes graphs illustrating the Equalize Voltage, Float Voltage, and Equalize Charging Time.
5. Maintenance
Regular maintenance ensures optimal performance and longevity of your inverter. Always disconnect all power sources (AC, PV, and Battery) before performing any maintenance.
- Cleaning: Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating. Use a soft, dry cloth for cleaning the exterior.
- Connections: Periodically check all electrical connections (battery, AC input/output, PV input) for tightness and corrosion. Loose connections can lead to poor performance or safety hazards.
- Battery Inspection: If using lead-acid batteries, check electrolyte levels and terminal condition as per battery manufacturer guidelines. For lithium batteries, monitor the BMS status via the inverter's display.
- Environment: Ensure the installation environment remains within the specified temperature and humidity ranges.
6. Troubleshooting
This section provides information on common issues, their possible causes, and corrective actions.
6.1. Fault Reference Code
When a fault occurs, the inverter's red FAULT LED will be solid on, and a fault code will be displayed on the LCD. Refer to the table below for common fault codes and their solutions.
| Fault Code | Fault Event | What to do |
|---|---|---|
| 01 | Fan is locked when inverter is off. | Replace the fan. |
| 02 | Over temperature | Check whether the air flow of the unit is blocked or whether the ambient temperature is too high. |
| 03 | Battery voltage is too high | Check if spec and quantity of batteries are meet requirements. |
| 04 | Battery voltage is too low | 1. Re-charge battery. 2. Replace battery. |
| 05 | Output short circuited or over temperature is detected by internal converter components. | Check if wiring is connected well and remove abnormal load. |
| 06 | Output voltage is too high. | 1. Reduce the connected load. 2. Return to repair center. |
| 07 | Overload time out | Reduce the connected load by switching off some equipment. |
| 08 | Bus voltage is too high | Return to repair center. |
| 09 | Bus soft start failed | Return to repair center. |
| 11 | Main relay failed | Return to repair center. |
| 51 | Over current or surge | Restart the unit, if the error happens again, please return to repair center. |
| 52 | Bus voltage is too low | Restart the unit, if the error happens again, please return to repair center. |
| 53 | Inverter soft start failed | Restart the unit, if the error happens again, please return to repair center. |
| 55 | Over DC voltage in AC output | Restart the unit, if the error happens again, please return to repair center. |
| 56 | Battery connection is open | If the battery is connected well, please return to repair center. |
| 57 | Current sensor failed | Return to repair center. |
| 58 | Output voltage is too low | 1. Reduce the connected load. 2. Return to repair center. |
6.2. Warning Indicator
When a warning condition occurs, the red FAULT LED will flash, and the inverter may beep. Refer to the table below for common warning codes and their descriptions.
| Warning Code | Warning Event | Audible Alarm |
|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep twice every second |
| 03 | Battery is over-charged | Beep twice every second |
| 04 | Low battery | Beep twice every second |
| 07 | Overload | Beep twice every second |
| 10 | Output power derating | Beep twice every second |
| 12 | Solar charger stops due to low battery. | |
| 13 | Solar charger stops due to high PV voltage. | |
| 14 | Solar charger stops due to overload. | |
| 15 | PV is weak | |
| 61 | When the battery communication is abnormal, stop charging and discharging. |
7. Specifications
7.1. Table 1 Line Mode Specifications
| INVERTER MODEL | 3.0KW/24V | 4.0KW/24V |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 120Vac | |
| Low Loss Voltage | 95Vac±5V(UPS); 65Vac±7V(Appliances) | |
| Low Loss Return Voltage | 100Vac±5V(UPS); 70Vac±5V(Appliances) | |
| High Loss Voltage | 140Vac±5V | |
| High Loss Return Voltage | 135Vac±5V | |
| Max AC Input Voltage | 150Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (It can be set in program 09) | |
| Low Loss Frequency | 45±1Hz/55±1Hz | |
| Low Loss Return Frequency | 47±1Hz/57±1Hz | |
| High Loss Frequency | 55±1Hz/65±1Hz | |
| High Loss Return Frequency | 53±1Hz/63±1Hz | |
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms typical (UPS); 20ms typical (Appliances) | |
7.2. Table 2 Inverter Mode Specifications
| INVERTER MODEL | 3.0KW/24V | 4.0KW/24V |
|---|---|---|
| Rated Output Power | 3.0KW | 4.0KW |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 120Vac±5% | |
| Output Frequency | 60Hz or 50Hz | |
| Peak Efficiency | 94% | |
| Overload Protection | 5s@≥150% load; 10s@110%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 24Vdc | |
| Cold Start Voltage | 23.0Vdc | |
| Low DC Warning Voltage | 22.0Vdc | |
| Low DC Warning Return Voltage | 23.0Vdc | |
| Low DC Cut-off Voltage | 21.0Vdc | |
| High DC Recovery Voltage | 29Vdc | |
| High DC Cut-off Voltage | 31Vdc | |
| No Load Power Consumption | <35W | |
7.3. Table 3 Charge Mode Specifications
Utility Charging Mode
| INVERTER MODEL | 3.0KW/24V | 4.0KW/24V |
|---|---|---|
| Charging Current (UPS) @ Nominal Input Voltage | 80A | 110A |
| Bulk Charging Voltage (Flooded) | 29.2Vdc | |
| Bulk Charging Voltage (AGM / Gel Battery) | 28.2Vdc | |
| Floating Charging Voltage | 27Vdc | |
| Charging Algorithm | 3-Step | |
Solar Charging Mode
| INVERTER MODEL | 3.0KW/24V | 4.0KW/24V |
|---|---|---|
| Rated Power | 5600W | |
| PV Charge Current | 100A | 140A |
| Efficiency | 98.0% max. | |
| Max. PV Array Open Circuit Voltage | 350Vdc | |
| PV Array MPPT Voltage Range | 55-350Vdc | |
| Standby Power Consumption | 2W | |
| Battery Voltage Accuracy | +/-0.3% | |
| PV Voltage Accuracy | +/-2V | |
| Charging Algorithm | 3-Step | |
7.4. Table 4 General Specifications
| INVERTER MODEL | 3.0KW/24V | 4.0KW/24V |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | 0°C to 55°C | |
| Storage temperature | -15°C~60°C | |
| Dimension (D*W*H), mm | 400*250*89mm | |
| Net Weight, kg | 7.5kg | 8.5kg |
7.5. Appendix: Approximate Back-up Time Table
| Model | Load (W) | Backup Time @ 24Vdc 100Ah (min) | Backup Time @ 24Vdc 200Ah (min) |
|---|---|---|---|
| 4.0KW | 300 | 449 | 1100 |
| 600 | 222 | 525 | |
| 900 | 124 | 303 | |
| 1200 | 95 | 227 | |
| 1500 | 68 | 164 | |
| 1800 | 56 | 126 | |
| 2100 | 48 | 108 | |
| 2400 | 35 | 94 | |
| 2700 | 31 | 74 | |
| 3200 | 28 | 67 |
Note:
- Backup time depends on the quality of the battery, age of battery, and type of battery.
- Specifications of batteries may vary depending on different manufacturers.
- Product technical specifications are subject to change without notice.
8. User Tips
- Battery Compatibility: This inverter is designed to work with 24V battery systems, including two 12V batteries in series. It supports various battery types like GEL, FLD, LI (Lithium), and AGM, as well as user-defined settings. It is compatible with LiFePo4 batteries.
- Battery-less Operation: The inverter can operate without a battery, drawing power directly from the PV array, which is useful for direct solar power utilization.
- LCD Button Orientation: Some users have noted that the 'Up' and 'Down' buttons on the LCD might function in reverse. Be aware of this during navigation and setting adjustments.
- Parallel Operation: The manual mentions parallel operation in a caution regarding AC wire polarity. While it implies the capability, specific instructions for parallel setup and the maximum number of units are not detailed in this document. Consult a qualified technician for multi-unit installations.
- WiFi Monitoring: The inverter supports an optional WiFi module for remote monitoring and control via a dedicated app.
- Grounding: Ensure proper grounding. The inverter/charger must be connected to a permanent grounded wiring system. Always connect the PE (Protective Earth) conductor first for safety.
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your local dealer or the manufacturer directly. Ensure you have your product model and serial number available when seeking support.
A detailed user manual in PDF format is available for download: View User Manual (PDF)