Y&H SY-SLCD (SY Series 60A/80A/100A)

Contents

Y&H SY-SLCD MPPT Solar Charge Controller User Manual

Model: SY-SLCD (SY Series 60A/80A/100A)

1. Introduction

Thank you for choosing the Y&H SY-SLCD MPPT Solar Charge Controller. This multi-functional LCD solar controller is designed to efficiently manage power from your solar panels to charge various battery types, including lead-acid and lithium batteries, and to power DC loads. It features a clock display and seven operating modes to ensure optimal performance and battery longevity. Please check that the product model matches your packaging upon opening.

2. Package Contents

  • 1 x Host Machine (Y&H SY-SLCD MPPT Solar Charge Controller)
  • 1 x User Manual
  • 1 x Pack of Desiccant

3. Specifications

FeatureDescription
ModelSY-SLCD (SY Series)
Charge Current60A / 80A / 100A
Input VoltageDC12V/24V, DC36V, DC48V, DC96V
Output VoltageDC12V/24V, DC36V, DC48V, DC5V/1.5A×2USB
Battery Voltage12V, 24V, 36V, 48V (Auto-sensing)
Operating Temperature-25°C ~ 55°C
ApplicationCharger Controller, Voltage Control, Solar Energy, Lighting Controller, Solar System Controller, Solar Working Station
CertificationCE
Is Smart DeviceNo
Dimensions (approx.)Length: 19cm, Width: 18cm, Height: 6cm
Weight (approx.)1.0 kg

The controller is designed for high efficiency, with up to 98% tracking efficiency and 99% conversion efficiency.

Wiring diagram for Y&H MPPT Solar Charge Controller showing connections for solar panels, battery, and load, along with efficiency ratings and a table of recommended photovoltaic input voltage and maximum PV input power for different battery voltages.
Figure 1: Wiring Diagram and Performance Specifications. This diagram illustrates the connection points for solar panels, battery, and load, highlighting the high tracking and conversion efficiencies. A table provides recommended photovoltaic input voltage and maximum PV input power for 12V, 24V, 36V, and 48V battery systems.

4. Product Features

  • Multi-functional LCD display with clock.
  • Seven operating modes: Charging, Light Control, Light and Time Delay Control, Universal Control, Manual Control, Timing Control, and Testing.
  • Charging control: Charges immediately when conditions are met.
  • Discharge control: Varies based on selected mode.
  • Compatible with multiple battery types: SLD GEL, Flooded, and Lithium batteries.
  • Four charging stages: Bulk Charge, Boost Charge, Float Charge, and Equalization Charge for rapid, efficient, and safe battery charging.
  • Built-in protections for low voltage, over-current, and over-temperature.
Image showing the Y&H MPPT Solar Charge Controller compatible with multiple battery types, specifically SLD GEL, Flooded, and Lithium batteries, emphasizing battery protection.
Figure 2: Battery Type Compatibility. The controller supports various battery chemistries, ensuring broad applicability and optimized charging.
Diagram illustrating the four charging stages of the Y&H MPPT Solar Charge Controller: Bulk Charge, Boost Charge, Float Charge, and Equalization Charge, designed for efficient and safe battery charging.
Figure 3: Four Charging Stages. The controller employs a sophisticated 4-stage charging algorithm to maximize battery life and performance.

5. Display and Operation Instructions

5.1. Display Screen

Detailed diagram of the Y&H MPPT Solar Charge Controller's LCD display interface, labeling areas for battery status, solar panel status, load output, mode control, and normal/fault status.
Figure 4: At-a-Glance Display Interface. The LCD provides comprehensive information about the system's status.

The LCD display is divided into several areas:

  1. Battery work status display area: Shows battery charging state and voltage. When charging, four dynamic bars indicate activity; static bars show current battery level. Battery voltage and discharge current toggle every 5 seconds.
  2. Operating status area of solar panel: When the solar panel icon is displayed, it indicates charging. If not displayed, charging has stopped. Displays charge current.
  3. Load output status and display areas of all parameters: When the battery discharges, the load icon is lit. When not discharging, it's off. Displays controller temperature (when 'C' is shown), battery electric quantity (when '%' is shown), and 24-hour time (when 'Time' is shown). 'Time ON' indicates timing start time.
  4. Mode control display area: 'Operate Mode Select' indicates the active control mode. 'Charging', 'Light Control', 'Light Control and delay', 'Universal Control', 'Manual', 'Timing', and 'Test' modes are displayed when active.
  5. Normal and fault status display area: 'OK' indicates normal operation. 'Fault' flickers for abnormalities in battery voltage, discharge current, or controller temperature.

5.2. Operation Buttons

  • ▲: Numerical values and mode adjustment (increase value).
  • MENU: Setting/confirmation.
  • ▼: Displacement and impulse start/stop (decrease value).

5.3. Time Setting

When charged, the controller enters time setting state. The first of the four values in the parameters display area will flicker, indicating it's changeable. Press "▲" to adjust the value, and "▼" for displacement. To re-enter time setting, long press "MENU" for 5 seconds.

5.4. Mode Adjustment

Press "MENU" to make the current control mode flicker. Use "▲" to select the desired control mode, then press "MENU" again to confirm.

5.5. Delay Stop Time Adjustment (Light Control + Delay Stop Control Mode)

When "Light Control and delay" is selected and confirmed, the delay stop time parameters will automatically appear. Adjust values using "▲" and "▼". The load output and display area will show "Time OFF". After adjustment, press "MENU" to return to display mode. To modify again, press "MENU" twice.

5.6. Timing Control Mode (Start and Stop Time Adjustment)

When "Timing" control mode is selected and confirmed, time parameters for start will appear. Adjust as with time setting. Load output and display area will show "Time ON". After adjusting start time and pressing "MENU", it will automatically enter stop time parameters adjustment. Load output and display area will show "Time OFF". After finishing adjustment, press "MENU" to return to display mode.

Play video
Watch video online
Video 1: Product Demonstration and Display Setting. This video shows the physical appearance of the solar charge controller and demonstrates how to navigate the menu and adjust settings on the LCD display.

6. Installation

The solar charge controller should be installed in a dry, well-ventilated area, away from direct sunlight and heat sources. Ensure adequate space around the unit for heat dissipation.

6.1. Wiring Connections

Follow the wiring diagram carefully. Connect components in the following order to prevent damage:

  1. Connect the Battery: Connect the battery to the controller's battery terminals (marked with '+' and '-'). Ensure correct polarity. The controller will automatically detect the battery voltage.
  2. Connect the Solar Panels: Connect the solar panels to the controller's solar terminals (marked with solar panel icon and '+' and '-'). Ensure correct polarity.
  3. Connect the Load: Connect your DC load to the controller's load terminals (marked with light bulb icon and '+' and '-'). Ensure correct polarity.

Important: Always connect the battery first, then the solar panels, and finally the load. Disconnect in the reverse order: load, then solar panels, then battery.

Front view of the Y&H MPPT Solar Charge Controller, showing the LCD display, control buttons (RESET, MENU, ON/OFF), and terminals for Solar, Battery, and Load connections. It also indicates 60A 12/24/36/48V AUTO.
Figure 5: Front View of the Controller. This image highlights the main components and connection points.
Internal view of the Y&H MPPT Solar Charge Controller circuit board, showing the terminal blocks for connections and dual USB ports. The image is a collage of the circuit board from different angles.
Figure 6: Internal Circuit Board and USB Ports. This view shows the robust internal components and the convenient dual USB output ports for charging devices.

7. Protection Parameters

7.1. Voltage Protection Instructions

  • 12V Battery:
    • Low Voltage Protection: Discharges stop if battery voltage is below 10.5V for 6 seconds.