1. About This Manual
This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of the PowMr POW-HVM Series Hybrid Inverter. Please read this manual thoroughly before installation and operation, and keep it for future reference. It includes essential safety guidelines, installation procedures, and information regarding tools and wiring.
2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It is very important to correctly operate this inverter/charger.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
- NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.
3. Introduction
The PowMr POW-HVM Series is a multi-function inverter/charger that combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a compact size. Its comprehensive LCD display allows users to configure settings such as battery charging current, AC/solar charger priority, and acceptable input voltage for various applications.
3.1 Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload/Over temperature/short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
3.2 Basic System Architecture
The following illustration shows a basic application for this inverter/charger. A complete running system typically includes a generator or utility power source and PV modules. Consult with your system integrator for other possible system architectures based on your specific requirements.
This inverter can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

3.3 Product Overview
The inverter features an LCD display, status indicators, and function buttons for easy operation. Below are the key components:


- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input
- AC output
- PV input
- Battery input
- Circuit breaker
- Output receptacles
4. Installation and Setup
4.1 Unpacking and Inspection
Before installation, carefully inspect the unit. Ensure that no damage occurred during transit. The package should contain:
- The inverter unit x 1
- User manual x 1
- U-terminal x 2

4.2 Preparation
Before connecting any wiring, remove the bottom cover by unscrewing the two screws as indicated in the full PDF manual.
4.3 Mounting the Unit
Consider the following points when selecting an installation location:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level for easy readability of the LCD display.
- For proper air circulation and heat dissipation, allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit.
- The ambient temperature should be between 0°C and 55°C for optimal operation.
- The recommended installation position is vertically on a wall.
- Ensure sufficient heat dissipation and space for wiring by keeping other objects and surfaces clear as shown in the diagram in the full PDF manual.
CAUTION: Suitable for mounting on concrete or other non-combustible surfaces only.
Install the unit using two M4 or M5 screws.
4.4 Battery Connection
CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. While a disconnect device may not always be required, over-current protection is essential. Refer to the table below for recommended fuse or breaker sizes.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It is crucial for system safety and efficient operation to use appropriate cables for battery connection. To reduce the risk of injury, use the recommended cable sizes below.
Recommended Battery Cable Size:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 1.0KW 12V | 1 x 6AWG | 14 | 5 Nm |
| 1.5KW 24V | 1 x 6AWG | 14 | 5 Nm |
Battery Connection Steps:
- Remove 18 mm of insulation sleeve from the positive and negative conductors.
- It is recommended to use bootlace ferrules on the ends of the positive and negative wires with a proper crimping tool.
- Connect all battery packs as shown in the diagram below.
- Insert the battery wires flatly into the inverter's battery connectors. Ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify that the polarity is correct at both the battery and the inverter/charger, and that conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.
CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).
4.5 AC Input/Output Connection
CAUTION!! Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. Recommended AC breaker spec: 20A for 1.0KW and 20A for 1.5KW.
CAUTION!! There are two terminal blocks labeled "IN" and "OUT". Do NOT mis-connect input and output connectors.
WARNING! All wiring must be performed by qualified personnel.
WARNING! It is critical for system safety and efficient operation to use appropriate cables for AC input connection. To reduce the risk of injury, use the recommended cable sizes below.
Suggested Cable Requirement for AC Wires:
| Model | Gauge | Torque Value |
|---|---|---|
| 1.0KW 12V | 14 AWG | 2 Nm |
| 1.5KW 24V | 12 AWG | 2 Nm |
AC Input/Output Connection Steps:
- Before making AC input/output connections, ensure the DC protector or disconnector is open.
- Remove 10 mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3 mm.
- Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (yellow-green) first.
- Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws.
WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.
4.6 PV Connection
CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.
WARNING! It is crucial for system safety and efficient operation to use appropriate cables for PV module connection. To reduce the risk of injury, use the recommended cable sizes below.
Recommended PV Module Cable Size:
| Model | Wire Size | Torque value (max) |
|---|---|---|
| 1.0KW 12V / 1.5KW 24V | 1x12AWG | 2 Nm |
PV Module Selection Parameters:
- Open Circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
- Open Circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
PV Module Wire Connection Steps:
- Remove 10 mm of insulation sleeve for positive and negative conductors.
- It is recommended to use bootlace ferrules on the ends of the positive and negative wires with a proper crimping tool.
- Check the correct polarity of wire connection from PV modules and PV input connectors. Connect the positive pole (+) of the connection wire to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection wire to the negative pole (-) of the PV input connector. Recommended tool: 4mm blade screwdriver.
4.7 Final Assembly
After all wirings are connected, replace the bottom cover by screwing in the four screws.
5. Operation
5.1 Power ON/OFF
Once the unit is properly installed and the batteries are connected, simply press the On/Off switch (located on the side of the unit) to turn on the unit.
5.2 Operation and Display Panel
The operation and display panel, located on the front of the inverter, includes three indicators, four function keys, and an LCD display. These components provide information on the operating status and input/output power.
LED Indicator Descriptions:
| LED Indicator | Color | Status | Messages |
|---|---|---|---|
| AC/INV | Green | Solid On | Output is powered by utility in Line mode. |
| Flashing | Output is powered by battery or PV in battery mode. | ||
| CHG | Green | Solid On | Battery is fully charged. |
| Flashing | Battery is charging. | ||
| FAULT | Red | Solid On | Fault occurs in the inverter. |
| Flashing | Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
5.3 LCD Setting
To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to navigate through the setting programs. Press "ENTER" to confirm a selection or "ESC" to exit. The manual provides detailed programs for configuring various parameters such as output source priority, maximum charging current, AC input voltage range, battery type, auto-restart functions, output frequency, output voltage, and battery equalization settings.
For a complete list of LCD setting programs and their detailed descriptions, please refer to the official user manual PDF: PowMr POW-HVM Series User Manual (PDF).
6. Maintenance
6.1 Clearance and Maintenance for Anti-Dust Kit (Optional)
Every inverter unit comes with an anti-dust kit installed from the factory. The inverter automatically detects this kit and adjusts its internal thermal sensor to regulate internal temperature. This kit helps prevent dust accumulation, enhancing product reliability in harsh environments.
Maintenance Steps:
- Remove the screws securing the dustproof case.
- Carefully remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and the dustproof case. After cleaning, re-assemble the dust-kit back into the inverter.
NOTICE: The anti-dust kit should be cleaned from dust every one month.

7. Troubleshooting
This section provides information on fault codes and warning indicators to help diagnose and resolve common issues. If problems persist after following these steps, please contact qualified service personnel.
7.1 Fault Reference Code
| Fault Code | Fault Event | Icon on |
|---|---|---|
| 01 | Fan is locked when inverter is off. | 01 |
| 02 | Over temperature | 02 |
| 03 | Battery voltage is too high | 03 |
| 04 | Battery voltage is too low | 04 |
| 05 | Output short circuited or over temperature is detected by internal converter components. | 05 |
| 06 | Output voltage is too high. | 06 |
| 07 | Overload time out | 07 |
| 08 | Bus voltage is too high | 08 |
| 09 | Bus soft start failed | 09 |
| 51 | Over current or surge | 51 |
| 52 | Bus voltage is too low | 52 |
| 53 | Inverter soft start failed | 53 |
| 55 | Over DC voltage in AC output | 55 |
| 57 | Current sensor failed | 57 |
| 58 | Output voltage is too low | 58 |
| 59 | PV voltage is over limitation | 59 |
7.2 Warning Indicator
| Warning Code | Warning Event | Audible Alarm | Icon flashing |
|---|---|---|---|
| 01 | Fan is locked when inverter is on. | Beep three times every second | 01 |
| 03 | Battery is over-charged | Beep once every second | 03 |
| 04 | Low battery | Beep once every second | 04 |
| 07 | Overload | Beep once every 0.5 second | 07 / OVER LOAD |
| 10 | Output power derating | Beep twice every 3 seconds | 10 |
| 15 | PV energy is low. | Beep twice every 3 seconds | 15 |
| E9 | Battery equalization | None | E9 |
8. Specifications
The following tables detail the technical specifications for the PowMr POW-HVM Series Hybrid Inverter.
8.1 Table 1 Line Mode Specifications
| INVERTER MODEL | 1.0KW-12V | 1.5KW-24V |
|---|---|---|
| Input Voltage Waveform | Sinusoidal (utility or generator) | |
| Nominal Input Voltage | 230Vac | |
| Low Loss Voltage | 170Vac±10V (UPS); 90Vac±10V (Appliances) | |
| Low Loss Return Voltage | 180Vac±10V (UPS); 100Vac±10V (Appliances) | |
| High Loss Voltage | 280Vac±10V | |
| High Loss Return Voltage | 270Vac±10V | |
| Max AC Input Voltage | 300Vac | |
| Nominal Input Frequency | 50Hz / 60Hz (Auto detection) | |
| Low Loss Frequency | 40±1Hz | |
| Low Loss Return Frequency | 42±1Hz | |
| High Loss Frequency | 65±1Hz | |
| High Loss Return Frequency | 63±1Hz | |
| Output Short Circuit Protection | Circuit Breaker | |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | |
| Transfer Time | 10ms | |
8.2 Table 2 Inverter Mode Specifications
| INVERTER MODEL | 1.0KW-12V | 1.5KW-24V |
|---|---|---|
| Rated Output Power | 1000VA/1000W | 1500VA/1500W |
| Output Voltage Waveform | Pure Sine Wave | |
| Output Voltage Regulation | 230Vac±5% | |
| Output Frequency | 50Hz | |
| Peak Efficiency | 94% | |
| Overload Protection | 3s@≥150% load; 5s@100%~150% load | |
| Surge Capacity | 2* rated power for 5 seconds | |
| Nominal DC Input Voltage | 12Vdc | 24Vdc |
| Cold Start Voltage | 11.5Vdc | 23.0Vdc |
| Low DC Warning Voltage @ load < 50% | 11.25Vdc | 22.5Vdc |
| Low DC Warning Voltage @ load ≥ 50% | 11.0Vdc | 22Vdc |
| Low DC Warning Return Voltage @ load < 50% | 11.75Vdc | 23.5Vdc |
| Low DC Warning Return Voltage @ load ≥ 50% | 11.5Vdc | 23Vdc |
| Low DC Cut-off Voltage @ load < 50% | 10.75Vdc | 21.5Vdc |
| Low DC Cut-off Voltage @ load ≥ 50% | 10.5Vdc | 21Vdc |
| High DC Recovery Voltage | 15.5Vdc | 31Vdc |
| High DC Cut-off Voltage | 16.0Vdc | 32Vdc |
| No Load Power Consumption | <28W | |
8.3 Table 3 Charge Mode Specifications
| Utility Charging Mode | 1.0KW-12V | 1.5KW-24V |
|---|---|---|
| Charging Algorithm | 3-Step | |
| AC Charging Current (Max) (@VI/P=230Vac) | 40Amp | 40Amp |
| Bulk Charging Voltage Flooded Battery | 14.6 | 29.2 |
| Bulk Charging Voltage AGM / Gel Battery | 14.1 | 28.2 |
| Floating Charging Voltage | 13.5Vdc | 27Vdc |
| MPPT Solar Charging Mode | 1.0KW-12V | 1.5KW-24V |
| Max. PV Array Power | 600W | 1200W |
| PV Array MPPT Voltage Range | 20~150Vdc | 30~150Vdc |
| Max. PV Array Open Circuit Voltage | 150Vdc | |
| Max solar charging current | 40Amp | |
| Max(AC+Solar) Charging current | 80Amp | |
8.4 Table 4 General Specifications
| INVERTER MODEL | 1.0KW-12V | 1.5KW-24V |
|---|---|---|
| Safety Certification | CE | |
| Operating Temperature Range | -10°C to 50°C | |
| Storage temperature | -15°C ~ 60°C | |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |
| Dimension (D*W*H), mm | 286X240X91 | |
| Net Weight, kg | 3 | 3.5 |
9. User Tips
- Output Voltage: Please note that this inverter provides a 230V AC output. It does not support 110V or 120V AC output. Ensure your appliances are compatible with 230V AC.
- Battery Type Selection: Carefully select the correct battery type (AGM, Flooded, or User-Defined) in the LCD settings (Program 05) to ensure optimal charging and battery lifespan.
- Cable Sizing: Always use the recommended wire sizes for battery, AC input/output, and PV connections to ensure safety and efficient operation, as specified in the installation section.
- Regular Maintenance: Clean the anti-dust kit monthly to maintain optimal performance and extend the inverter's lifespan, especially in dusty environments.
10. Warranty and Support
For detailed warranty information and technical support, please contact PowMr directly. You can find comprehensive information, including troubleshooting guides and detailed specifications, in the official user manual PDF.
Official User Manual (PDF): PowMr POW-HVM Series User Manual (PDF)
Contact Information:
- Brand: PowMr
- Manufacturer: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
- Tel/Fax: +86755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China