PowMr POW-HVM Series

Contents

PowMr POW-HVM Series Hybrid Inverter User Manual

Models: POW-HVM1K-12V, POW-HVM1.5K-24V

1. About This Manual

This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of the PowMr POW-HVM Series Hybrid Inverter. Please read this manual thoroughly before installation and operation, and keep it for future reference. It includes essential safety guidelines, installation procedures, and information regarding tools and wiring.

2. Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required specifications to select appropriate cable size. It is very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow the installation procedure when you want to disconnect AC or DC terminals. Please refer to the INSTALLATION section of this manual for details.
  10. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulations to install this inverter.
  11. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following the troubleshooting table, please send this inverter/charger back to a local dealer or service center for maintenance.

3. Introduction

The PowMr POW-HVM Series is a multi-function inverter/charger that combines the functions of an inverter, solar charger, and battery charger to provide uninterruptible power support in a compact size. Its comprehensive LCD display allows users to configure settings such as battery charging current, AC/solar charger priority, and acceptable input voltage for various applications.

3.1 Features

  • Pure sine wave inverter
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible with mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload/Over temperature/short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function

3.2 Basic System Architecture

The following illustration shows a basic application for this inverter/charger. A complete running system typically includes a generator or utility power source and PV modules. Consult with your system integrator for other possible system architectures based on your specific requirements.

This inverter can power various appliances in home or office environments, including motor-type appliances such as tube lights, fans, refrigerators, and air conditioners.

Diagram of Hybrid Power System showing solar panels, inverter, battery, utility/generator, and home appliances.
Figure 1: Hybrid Power System Diagram. This diagram illustrates the connections between solar power, a generator or utility, the inverter, external battery packs, and home appliances.

3.3 Product Overview

The inverter features an LCD display, status indicators, and function buttons for easy operation. Below are the key components:

Front view of PowMr Solar Inverter Charger showing LCD display, buttons, and caution labels.
Front view of the PowMr Solar Inverter Charger, highlighting the LCD display and control buttons.
Angled view of PowMr Solar Inverter Charger showing AC output, battery, and PV input terminals.
Angled view of the inverter, showing the AC output receptacles, AC input, battery input, and PV input terminals.
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. Circuit breaker
  12. Output receptacles

4. Installation and Setup

4.1 Unpacking and Inspection

Before installation, carefully inspect the unit. Ensure that no damage occurred during transit. The package should contain:

  • The inverter unit x 1
  • User manual x 1
  • U-terminal x 2
Contents of the PowMr Solar Inverter Charger package, showing the user manual and U-terminals.
Package contents: User Manual and U-terminals.

4.2 Preparation

Before connecting any wiring, remove the bottom cover by unscrewing the two screws as indicated in the full PDF manual.

4.3 Mounting the Unit

Consider the following points when selecting an installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level for easy readability of the LCD display.
  • For proper air circulation and heat dissipation, allow a clearance of approximately 20 cm to the sides and 50 cm above and below the unit.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • The recommended installation position is vertically on a wall.
  • Ensure sufficient heat dissipation and space for wiring by keeping other objects and surfaces clear as shown in the diagram in the full PDF manual.

CAUTION: Suitable for mounting on concrete or other non-combustible surfaces only.

Install the unit using two M4 or M5 screws.

4.4 Battery Connection

CAUTION: For safety and compliance, install a separate DC over-current protector or disconnect device between the battery and inverter. While a disconnect device may not always be required, over-current protection is essential. Refer to the table below for recommended fuse or breaker sizes.

WARNING! All wiring must be performed by qualified personnel.

WARNING! It is crucial for system safety and efficient operation to use appropriate cables for battery connection. To reduce the risk of injury, use the recommended cable sizes below.

ModelWire SizeCable (mm²)Torque value (max)
1.0KW 12V1 x 6AWG145 Nm
1.5KW 24V1 x 6AWG145 Nm

Battery Connection Steps:

  1. Remove 18 mm of insulation sleeve from the positive and negative conductors.
  2. It is recommended to use bootlace ferrules on the ends of the positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into the inverter's battery connectors. Ensure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Verify that the polarity is correct at both the battery and the inverter/charger, and that conductors are tightly screwed into the battery terminals. Recommended tool: #2 Pozi Screwdriver.
Diagram showing battery connection for 1.0KW 12V and 1.5KW 24V inverters.
Battery connection diagrams for 1.0KW 12V and 1.5KW 24V models. Shows parallel connection for 12V batteries to achieve 12V or 24V system voltage.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION!! Before making the final DC connection or closing the DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) is connected to negative (-).

4.5 AC Input/Output Connection

CAUTION!! Before connecting to an AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is fully protected from overcurrent. Recommended AC breaker spec: 20A for 1.0KW and 20A for 1.5KW.

CAUTION!! There are two terminal blocks labeled "IN" and "OUT". Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel.

WARNING! It is critical for system safety and efficient operation to use appropriate cables for AC input connection. To reduce the risk of injury, use the recommended cable sizes below.

Suggested Cable Requirement for AC Wires:

ModelGaugeTorque Value
1.0KW 12V14 AWG2 Nm
1.5KW 24V12 AWG2 Nm

AC Input/Output Connection Steps:

  1. Before making AC input/output connections, ensure the DC protector or disconnector is open.
  2. Remove 10 mm of insulation sleeve for six conductors. Shorten phase L and neutral conductor N by 3 mm.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (yellow-green) first.
  4. Then, insert AC output wires according to the polarities indicated on the terminal block and tighten the terminal screws.

WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.

4.6 PV Connection

CAUTION: Before connecting to PV modules, install a separate DC circuit breaker between the inverter and PV modules.

WARNING! It is crucial for system safety and efficient operation to use appropriate cables for PV module connection. To reduce the risk of injury, use the recommended cable sizes below.

ModelWire SizeTorque value (max)
1.0KW 12V / 1.5KW 24V1x12AWG2 Nm

PV Module Selection Parameters:

  • Open Circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
  • Open Circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.

PV Module Wire Connection Steps:

  1. Remove 10 mm of insulation sleeve for positive and negative conductors.
  2. It is recommended to use bootlace ferrules on the ends of the positive and negative wires with a proper crimping tool.
  3. Check the correct polarity of wire connection from PV modules and PV input connectors. Connect the positive pole (+) of the connection wire to the positive pole (+) of the PV input connector. Connect the negative pole (-) of the connection wire to the negative pole (-) of the PV input connector. Recommended tool: 4mm blade screwdriver.

4.7 Final Assembly

After all wirings are connected, replace the bottom cover by screwing in the four screws.

5. Operation

5.1 Power ON/OFF

Once the unit is properly installed and the batteries are connected, simply press the On/Off switch (located on the side of the unit) to turn on the unit.

5.2 Operation and Display Panel

The operation and display panel, located on the front of the inverter, includes three indicators, four function keys, and an LCD display. These components provide information on the operating status and input/output power.

LED Indicator Descriptions:

LED IndicatorColorStatusMessages
AC/INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

5.3 LCD Setting

To enter setting mode, press and hold the ENTER button for 3 seconds. Use the "UP" or "DOWN" buttons to navigate through the setting programs. Press "ENTER" to confirm a selection or "ESC" to exit. The manual provides detailed programs for configuring various parameters such as output source priority, maximum charging current, AC input voltage range, battery type, auto-restart functions, output frequency, output voltage, and battery equalization settings.

For a complete list of LCD setting programs and their detailed descriptions, please refer to the official user manual PDF: PowMr POW-HVM Series User Manual (PDF).

6. Maintenance

6.1 Clearance and Maintenance for Anti-Dust Kit (Optional)

Every inverter unit comes with an anti-dust kit installed from the factory. The inverter automatically detects this kit and adjusts its internal thermal sensor to regulate internal temperature. This kit helps prevent dust accumulation, enhancing product reliability in harsh environments.

Maintenance Steps:

  1. Remove the screws securing the dustproof case.
  2. Carefully remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and the dustproof case. After cleaning, re-assemble the dust-kit back into the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

Diagram illustrating the removal of the dustproof case and air filter foam for maintenance.
General view of the inverter. For specific diagrams on dust kit removal, refer to the official PDF manual.

7. Troubleshooting

This section provides information on fault codes and warning indicators to help diagnose and resolve common issues. If problems persist after following these steps, please contact qualified service personnel.

7.1 Fault Reference Code

Fault CodeFault EventIcon on
01Fan is locked when inverter is off.01
02Over temperature02
03Battery voltage is too high03
04Battery voltage is too low04
05Output short circuited or over temperature is detected by internal converter components.05
06Output voltage is too high.06
07Overload time out07
08Bus voltage is too high08
09Bus soft start failed09
51Over current or surge51
52Bus voltage is too low52
53Inverter soft start failed53
55Over DC voltage in AC output55
57Current sensor failed57
58Output voltage is too low58
59PV voltage is over limitation59

7.2 Warning Indicator

Warning CodeWarning EventAudible AlarmIcon flashing
01Fan is locked when inverter is on.Beep three times every second01
03Battery is over-chargedBeep once every second03
04Low batteryBeep once every second04
07OverloadBeep once every 0.5 second07 / OVER LOAD
10Output power deratingBeep twice every 3 seconds10
15PV energy is low.Beep twice every 3 seconds15
E9Battery equalizationNoneE9

8. Specifications

The following tables detail the technical specifications for the PowMr POW-HVM Series Hybrid Inverter.

8.1 Table 1 Line Mode Specifications

INVERTER MODEL1.0KW-12V1.5KW-24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±10V (UPS); 90Vac±10V (Appliances)
Low Loss Return Voltage180Vac±10V (UPS); 100Vac±10V (Appliances)
High Loss Voltage280Vac±10V
High Loss Return Voltage270Vac±10V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms

8.2 Table 2 Inverter Mode Specifications

INVERTER MODEL1.0KW-12V1.5KW-24V
Rated Output Power1000VA/1000W1500VA/1500W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency94%
Overload Protection3s@≥150% load; 5s@100%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage12Vdc24Vdc
Cold Start Voltage11.5Vdc23.0Vdc
Low DC Warning Voltage @ load < 50%11.25Vdc22.5Vdc
Low DC Warning Voltage @ load ≥ 50%11.0Vdc22Vdc
Low DC Warning Return Voltage @ load < 50%11.75Vdc23.5Vdc
Low DC Warning Return Voltage @ load ≥ 50%11.5Vdc23Vdc
Low DC Cut-off Voltage @ load < 50%10.75Vdc21.5Vdc
Low DC Cut-off Voltage @ load ≥ 50%10.5Vdc21Vdc
High DC Recovery Voltage15.5Vdc31Vdc
High DC Cut-off Voltage16.0Vdc32Vdc
No Load Power Consumption<28W

8.3 Table 3 Charge Mode Specifications

Utility Charging Mode1.0KW-12V1.5KW-24V
Charging Algorithm3-Step
AC Charging Current (Max) (@VI/P=230Vac)40Amp40Amp
Bulk Charging Voltage Flooded Battery14.629.2
Bulk Charging Voltage AGM / Gel Battery14.128.2
Floating Charging Voltage13.5Vdc27Vdc
MPPT Solar Charging Mode1.0KW-12V1.5KW-24V
Max. PV Array Power600W1200W
PV Array MPPT Voltage Range20~150Vdc30~150Vdc
Max. PV Array Open Circuit Voltage150Vdc
Max solar charging current40Amp
Max(AC+Solar) Charging current80Amp

8.4 Table 4 General Specifications

INVERTER MODEL1.0KW-12V1.5KW-24V
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage temperature-15°C ~ 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm286X240X91
Net Weight, kg33.5

9. User Tips

  • Output Voltage: Please note that this inverter provides a 230V AC output. It does not support 110V or 120V AC output. Ensure your appliances are compatible with 230V AC.
  • Battery Type Selection: Carefully select the correct battery type (AGM, Flooded, or User-Defined) in the LCD settings (Program 05) to ensure optimal charging and battery lifespan.
  • Cable Sizing: Always use the recommended wire sizes for battery, AC input/output, and PV connections to ensure safety and efficient operation, as specified in the installation section.
  • Regular Maintenance: Clean the anti-dust kit monthly to maintain optimal performance and extend the inverter's lifespan, especially in dusty environments.

10. Warranty and Support

For detailed warranty information and technical support, please contact PowMr directly. You can find comprehensive information, including troubleshooting guides and detailed specifications, in the official user manual PDF.

Official User Manual (PDF): PowMr POW-HVM Series User Manual (PDF)

Contact Information:

  • Brand: PowMr
  • Manufacturer: SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD
  • Tel/Fax: +86755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.