1. Product Overview

The Gaqqee TS457 is a versatile Voltage Internal Resistance Tester designed for precise measurement of voltage and internal resistance using the AC 4-wire Kelvin method. It features a clear digital display with adjustable backlight, intelligent power-saving functions, and data recording capabilities, making it suitable for various electrical testing applications, including 18650 dry batteries.

TS457 Voltage Internal Resistance Tester with accessories
Figure 1: TS457 Voltage Internal Resistance Tester and included accessories.

2. Specifications

FeatureSpecification
Model NumberTS457
Brand NameGaqqee
Working VoltageDC5V (Do not overvoltage power supply, max 45V)
Test PrincipleAC 4-wire method
Voltage Testing Range0.001V ~ 45.00V
Voltage Resolution0.001V
Internal Resistance Range0.1mΩ ~ 6.999Ω
Internal Resistance Resolution0.1mΩ
Data RecordingSupports recording 5 groups of internal resistance data
Voltage Display Fine-tuningSupported
Internal Resistance Display Fine-tuningSupported
Automatic ShutdownAdjustable from 1 to 9 minutes
Backlight Brightness1-9 levels adjustable
Dimensions79.5 x 42.1 x 27.8 mm
Installation Hole77 x 39.3 mm
Power Supply MethodDC5V, 18650 battery, or 18650 battery + power transfer board (purchased separately)
Battery IncludedNo
Display TypeDigital Only
DIY SuppliesElectrical
CertificationCE
TS457 Voltage Internal Resistance Tester dimensions
Figure 2: Product dimensions of the TS457 tester.

3. Setup

3.1 Power Supply Connection

The TS457 can be powered by a DC5V source or an 18650 battery. Ensure the power supply does not exceed 45V.

DC5V or 18650 Battery Two-Wire Supply Method:

Connect the fine red wire to the positive electrode and the fine black wire to the negative electrode. The yellow wire is not used for this power method.

DC5V or 18650 battery two-wire supply method wiring diagram
Figure 3: Wiring diagram for DC5V or 18650 battery two-wire power supply. Red to positive, black to negative.

Using 18650 Battery with Power Transfer Board:

If using an 18650 battery with a power transfer board (purchased separately), connect the board to the tester as shown in the diagram. This method provides a convenient way to power the device using an 18650 battery.

18650 Battery and power transfer board connection
Figure 4: Connection of an 18650 battery with a power transfer board to the TS457 tester.

3.2 Test Probe Connection

The tester uses an AC 4-wire method for accurate measurements. Connect the XH-2.54-4P signal acquisition cable to the appropriate port on the tester. The other end of this cable connects to your Kelvin clips or test probes for measuring the voltage and internal resistance of the target device.

WARNING: Do NOT test AC power. Do NOT test voltages above 45V.

4. Operating Instructions

4.1 Display Overview

The TS457 features a clear digital display showing real-time voltage, resistance, and data. The display includes a battery indicator and a clock.

TS457 Voltage Internal Resistance Tester display
Figure 5: The main display interface of the TS457 tester, showing voltage, resistance, and data fields.

4.2 Button Functions

  • Up Arrow Button (▲): Used for navigation and increasing values in settings.
  • M Button (M): Mode or Menu button, typically used to enter settings or switch modes.
  • Down Arrow Button (▼): Used for navigation and decreasing values in settings.
  • R Button (R): Reset or Record button, used for specific functions like data recording or resetting.

4.3 Fine Adjustment of Display

The tester supports fine-tuning for both voltage and internal resistance display. This feature allows users to make precise adjustments to ensure accurate readings and improve test reliability.

Fine adjustment of voltage and internal resistance display
Figure 6: The fine adjustment capability for voltage and internal resistance readings.

4.4 Backlight Brightness Adjustment

The device offers 1-9 levels of backlight brightness adjustment. Users can adjust the screen brightness to a comfortable level for optimal visibility in various lighting conditions, from strong light to dim environments.

Adaptive visual experience with backlight adjustment
Figure 7: The display showing different backlight brightness levels for adaptive visual experience.

4.5 Intelligent Power Saving and Automatic Shutdown

The standby time can be flexibly set from 1 to 9 minutes. The device will automatically enter an energy-saving mode based on usage frequency, effectively extending battery life.

Display showing standby settings
Figure 8: Menu interface for adjusting standby time and other settings.

4.6 Data Recording

The built-in storage function automatically records the last 5 groups of internal resistance measurement data. This allows for easy comparison and analysis on-site or for follow-up access, improving work efficiency and providing valuable data support for quality control and troubleshooting.

Display showing data recording feature
Figure 9: The display indicating the data recording capability.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the tester in a dry environment, away from direct sunlight and extreme temperatures.
  • Battery Care: If using an 18650 battery, ensure it is charged properly and replaced when necessary. Do not expose batteries to high temperatures or physical damage.
  • Probe Care: Keep test probes and Kelvin clips clean and free from corrosion to ensure accurate readings.

6. Troubleshooting

  • No Display/Power: Check the power supply connection. Ensure DC5V is correctly applied or the 18650 battery is charged and properly installed.
  • Inaccurate Readings: Utilize the voltage and internal resistance fine-tuning functions to calibrate the device. Ensure test probes are clean and making good contact. Verify the test object is within the specified measurement ranges.
  • Device Not Responding: Try resetting the device via the menu (refer to Figure 8). If issues persist, disconnect and reconnect the power supply.
  • Important Safety Note: Never attempt to test AC power or voltages exceeding 45V, as this can damage the device and pose a safety risk.

7. User Tips

  • Probe Quality: For optimal accuracy, consider using high-quality Kelvin clips or test probes, as the quality of probes can significantly impact measurement results.
  • Battery Testing Reference: New 18650 batteries typically show an internal resistance around 18-22 mOhm. Older or degraded batteries may show higher values, such as 45-50 mOhm.
  • Physical Inspection: Upon receiving the product, carefully inspect its physical integrity. Ensure all components are securely attached and there are no visible damages.
  • Small Resistor Accuracy: This device is noted for its accuracy when measuring small resistance values.

8. Warranty and Support

For specific warranty information and technical support, please refer to the seller or manufacturer directly. Keep your purchase records for any warranty claims.

Additional item guides and documents, including a user manual in PDF format, may be available from the seller. For example, a PDF manual can be found at: User manual (PDF).

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.