1. Product Overview
The Gaqqee TS457 is a versatile Voltage Internal Resistance Tester designed for precise measurement of voltage and internal resistance using the AC 4-wire Kelvin method. It features a clear digital display with adjustable backlight, intelligent power-saving functions, and data recording capabilities, making it suitable for various electrical testing applications, including 18650 dry batteries.

2. Specifications
| Feature | Specification |
|---|---|
| Model Number | TS457 |
| Brand Name | Gaqqee |
| Working Voltage | DC5V (Do not overvoltage power supply, max 45V) |
| Test Principle | AC 4-wire method |
| Voltage Testing Range | 0.001V ~ 45.00V |
| Voltage Resolution | 0.001V |
| Internal Resistance Range | 0.1mΩ ~ 6.999Ω |
| Internal Resistance Resolution | 0.1mΩ |
| Data Recording | Supports recording 5 groups of internal resistance data |
| Voltage Display Fine-tuning | Supported |
| Internal Resistance Display Fine-tuning | Supported |
| Automatic Shutdown | Adjustable from 1 to 9 minutes |
| Backlight Brightness | 1-9 levels adjustable |
| Dimensions | 79.5 x 42.1 x 27.8 mm |
| Installation Hole | 77 x 39.3 mm |
| Power Supply Method | DC5V, 18650 battery, or 18650 battery + power transfer board (purchased separately) |
| Battery Included | No |
| Display Type | Digital Only |
| DIY Supplies | Electrical |
| Certification | CE |

3. Setup
3.1 Power Supply Connection
The TS457 can be powered by a DC5V source or an 18650 battery. Ensure the power supply does not exceed 45V.
DC5V or 18650 Battery Two-Wire Supply Method:
Connect the fine red wire to the positive electrode and the fine black wire to the negative electrode. The yellow wire is not used for this power method.

Using 18650 Battery with Power Transfer Board:
If using an 18650 battery with a power transfer board (purchased separately), connect the board to the tester as shown in the diagram. This method provides a convenient way to power the device using an 18650 battery.

3.2 Test Probe Connection
The tester uses an AC 4-wire method for accurate measurements. Connect the XH-2.54-4P signal acquisition cable to the appropriate port on the tester. The other end of this cable connects to your Kelvin clips or test probes for measuring the voltage and internal resistance of the target device.
WARNING: Do NOT test AC power. Do NOT test voltages above 45V.
4. Operating Instructions
4.1 Display Overview
The TS457 features a clear digital display showing real-time voltage, resistance, and data. The display includes a battery indicator and a clock.

4.2 Button Functions
- Up Arrow Button (▲): Used for navigation and increasing values in settings.
- M Button (M): Mode or Menu button, typically used to enter settings or switch modes.
- Down Arrow Button (▼): Used for navigation and decreasing values in settings.
- R Button (R): Reset or Record button, used for specific functions like data recording or resetting.
4.3 Fine Adjustment of Display
The tester supports fine-tuning for both voltage and internal resistance display. This feature allows users to make precise adjustments to ensure accurate readings and improve test reliability.

4.4 Backlight Brightness Adjustment
The device offers 1-9 levels of backlight brightness adjustment. Users can adjust the screen brightness to a comfortable level for optimal visibility in various lighting conditions, from strong light to dim environments.

4.5 Intelligent Power Saving and Automatic Shutdown
The standby time can be flexibly set from 1 to 9 minutes. The device will automatically enter an energy-saving mode based on usage frequency, effectively extending battery life.

4.6 Data Recording
The built-in storage function automatically records the last 5 groups of internal resistance measurement data. This allows for easy comparison and analysis on-site or for follow-up access, improving work efficiency and providing valuable data support for quality control and troubleshooting.

5. Maintenance
- Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
- Storage: Store the tester in a dry environment, away from direct sunlight and extreme temperatures.
- Battery Care: If using an 18650 battery, ensure it is charged properly and replaced when necessary. Do not expose batteries to high temperatures or physical damage.
- Probe Care: Keep test probes and Kelvin clips clean and free from corrosion to ensure accurate readings.
6. Troubleshooting
- No Display/Power: Check the power supply connection. Ensure DC5V is correctly applied or the 18650 battery is charged and properly installed.
- Inaccurate Readings: Utilize the voltage and internal resistance fine-tuning functions to calibrate the device. Ensure test probes are clean and making good contact. Verify the test object is within the specified measurement ranges.
- Device Not Responding: Try resetting the device via the menu (refer to Figure 8). If issues persist, disconnect and reconnect the power supply.
- Important Safety Note: Never attempt to test AC power or voltages exceeding 45V, as this can damage the device and pose a safety risk.
7. User Tips
- Probe Quality: For optimal accuracy, consider using high-quality Kelvin clips or test probes, as the quality of probes can significantly impact measurement results.
- Battery Testing Reference: New 18650 batteries typically show an internal resistance around 18-22 mOhm. Older or degraded batteries may show higher values, such as 45-50 mOhm.
- Physical Inspection: Upon receiving the product, carefully inspect its physical integrity. Ensure all components are securely attached and there are no visible damages.
- Small Resistor Accuracy: This device is noted for its accuracy when measuring small resistance values.
8. Warranty and Support
For specific warranty information and technical support, please refer to the seller or manufacturer directly. Keep your purchase records for any warranty claims.
Additional item guides and documents, including a user manual in PDF format, may be available from the seller. For example, a PDF manual can be found at: User manual (PDF).