Safety Information
CAUTION! All liquid coolers have a probability of leakage. Please check for any external deformation before installation. If any deformation is found, immediately contact customer service for confirmation.
- Ensure all components are handled with care to prevent damage.
- Do not attempt to modify the cooler or its components.
- Keep out of reach of children.
- Refer to the official user manual PDF for additional safety guidelines.
For the complete user manual in PDF format, please refer to the Thermalright FW 240 User Manual (PDF).
Package Contents
Please verify that all components are present before proceeding with installation.
Image: Overview of the SS2 buckle system components, including various screws, standoffs, and mounting brackets for different CPU sockets.
Component List (Refer to "附件清单" in the PDF)
- Radiator with integrated pump and cold plate
- Two TL-P12W-S fans (pre-installed on some models)
- Mounting hardware for Intel platforms (LGA1700, LGA115X, LGA1200, LGA2011, LGA2066, LGA1851)
- Mounting hardware for AMD platforms (AM5, AM4)
- Backplates (Intel LGA 115X/1700 adjustable backplate)
- Screws and standoffs specific to each socket type
- Thermal paste (TF7 heat conduction silicone grease)
- Water pipe buckles
Installation Guide
This section outlines the general installation process. Specific steps may vary slightly depending on your CPU socket and PC case. Always refer to the detailed diagrams.
1. Prepare the Motherboard
- Ensure your motherboard is compatible with the cooler (Supported CPU: Intel LGA 2066, LGA 1155, LGA1200, LGA 1700, LGA 1851, LGA 115X, LGA 2011; AMD AM4, Socket AM5).
- For Intel LGA 115X/1700, adjust the backplate according to your socket type. The backplate has adjustable positions for LGA 1700/1851 and LGA 115X/1200.
- Install the appropriate standoffs onto the backplate.
Image: Excerpt from the user manual showing the component list and detailed diagrams for Intel LGA 115X/1700 backplate installation, including screw types and positions.
2. Apply Thermal Paste
- Clean the CPU surface thoroughly.
- Apply a small amount of the provided TF7 thermal paste to the center of the CPU.
- Do not spread the paste; the pressure from the cold plate will distribute it evenly.
3. Install the Cold Plate/Pump
- Carefully place the cold plate onto the CPU, aligning the mounting holes with the standoffs.
- Secure the cold plate with the appropriate screws, tightening them in a cross pattern until snug. Do not overtighten.
Image: The Thermalright FW 240 White ARGB cooler installed in a system, highlighting the cold plate and its LCD display.
4. Mount the Radiator and Fans
- Mount the radiator to an available fan slot in your PC case (typically top or front).
- Ensure the fans are oriented to provide optimal airflow (intake or exhaust, depending on your case configuration).
- The TL-P12W-S fans may come pre-installed on the radiator.
Image: The Thermalright FW 240 White ARGB cooler, showing the radiator, two fans, and the pump/cold plate unit.
5. Connect Cables
- Connect the pump's 4-pin PWM cable to the CPU_FAN or AIO_PUMP header on your motherboard.
- Connect the fan's 4-pin PWM cables to available fan headers on your motherboard or a fan controller.
- Connect the ARGB interface (+5V/3PIN ARGB) cables from the pump and fans to your motherboard's ARGB header or a dedicated ARGB controller.
- Connect the USB cable from the pump to an available internal USB 2.0 header on your motherboard for LCD display control.
Operation and Software
LCD Display Features
The FW 240 features a 2.4-inch IPS LCD screen with 320*240 resolution and 450 Nits peak brightness. This screen supports personalized JPG, PNG, and GIF images, allowing for custom display content.
Image: A close-up view of the cooler's LCD screen, showing real-time CPU temperature (34°C), frequency (1995MHz), and CPU usage (1%).
Image: The 2.4-inch LCD screen displaying GPU temperature and usage, demonstrating its customizable monitoring capabilities.
TRCC Water-Cooled LCD Screen Control Software
To customize the LCD display and monitor various system parameters, use the TRCC water-cooled LCD screen control software. This software allows you to:
- Display CPU temperature, frequency, and usage.
- Display GPU temperature and usage.
- Customize the background and theme of the display.
- Upload personalized images (JPG, PNG, GIF) to the screen.
- Monitor other system states (M1-M6 corresponding to system states).
Image: Screenshots illustrating the TRCC software interface, showing options for monitoring system parameters, customizing themes, and managing display settings. The software allows for dynamic display of CPU/GPU metrics and custom backgrounds.
After the system status display is set, the theme can be saved, and the background can be replaced without changing the system status display. An explanation document is available within the software interface.
ARGB Lighting Control
The A-RGB lighting on the fans and pump can be controlled via your motherboard's ARGB software (if connected to an ARGB header) or a compatible ARGB controller.
Maintenance
- Dust Cleaning: Regularly clean the radiator fins and fan blades with compressed air to prevent dust buildup, which can impede cooling performance.
- Cable Management: Ensure all cables are neatly routed and secured to prevent interference with fan operation or accidental disconnections.
- Visual Inspection: Periodically inspect the tubing and connections for any signs of leaks or damage. While liquid coolers are designed to be sealed, vigilance is recommended.
- Software Updates: Keep the TRCC software and your motherboard's BIOS/drivers updated for optimal performance and compatibility.
Troubleshooting
- High CPU Temperatures:
- Check if the cold plate is securely mounted to the CPU.
- Ensure thermal paste was applied correctly.
- Verify that the pump and fans are spinning. Check cable connections.
- Clean any dust from the radiator fins.
- Ensure proper airflow within your PC case.
- LCD Display Not Working:
- Ensure the internal USB 2.0 cable from the pump is securely connected to the motherboard.
- Check if the TRCC software is installed and running.
- Restart your system.
- Fans/Pump Not Spinning or ARGB Not Lighting Up:
- Verify all power and ARGB cables are correctly connected to the motherboard or controller.
- Check your motherboard's BIOS/UEFI settings to ensure fan headers are configured correctly.
- Ensure your ARGB software is properly configured.
Specifications
| Feature | Detail |
|---|---|
| Brand Name | Thermalright |
| Model Number | FW240 |
| Type | CPU All In One Liquid Cooler |
| Supported CPU Sockets | Intel: LGA 2066, LGA 1155, LGA1200, LGA 1700, LGA 1851, LGA 115X, LGA 2011 AMD: AM4, Socket AM5 |
| Radiator Type | 240 MM |
| Radiator Size | 277mm * 120mm * 27mm |
| Cold Head Size | 69.2mm * 69.2mm * 60mm |
| Water Guide Length | 450mm |
| Heatsink Material | Copper & Aluminum |
| RGB Support | A-RGB |
| With Screen | Yes, 2.4-inch IPS LCD (320*240 resolution, 450 Nits peak brightness, 24bit color) |
| With Liquid | Yes |
| Package | Yes |
| Origin | Mainland China |
Pump Parameters
Image: Diagram illustrating the Corev1.0 independent water pump framework, highlighting the 9-pole rotor motor, fluid impeller, and micro-dental shovel technology. This design aims for increased heat absorption rate (23%), increased heat exchange rate (17%), and reduced noise (33%).
| Parameter | Value |
|---|---|
| Speed | 3000RPM+10% |
| Voltage | DC 12V |
| Current | 0.28+10%A |
| Noise | ≤23DB(A) |
| Interface | 4PIN PWM |
| Power | ≤3.4W |
| ARGB Interface | +5V/3PIN ARGB |
Fan Parameters (TL-P12W-S)
| Parameter | Value |
|---|---|
| Size | 120 * 120 * 25MM |
| Speed | 2000RPM+10%(MAX) |
| Voltage | DC 12V |
| Current | 0.17A |
| Wind Pressure | 2.63MM H₂O(MAX) |
| Air Volume | 70.84CFM(MAX) |
| Noise | ≤22.1DB(A) |
| Interface | 4PIN PWM |
| ARGB Interface | +5V/3PIN ARGB |
| Bearing | S-FDB BEARING |
Note: Specifications are subject to change without notice.
User Tips
- For optimal cooling, ensure your PC case has good airflow and that the radiator fans are configured to either push or pull air efficiently through the radiator.
- Experiment with different display settings and custom images on the LCD screen using the TRCC software to personalize your build.
- Regularly monitor CPU and GPU temperatures through the LCD display or software to ensure your system is running within safe operating limits.
- When installing, pay close attention to the orientation of the cold plate and radiator to avoid kinks in the tubing, which can restrict coolant flow.
Warranty and Support
The Thermalright FW 240 ARGB All-in-One Liquid CPU Cooler comes with a 3-year warranty from the date of purchase.
For technical support, warranty claims, or further assistance, please contact Thermalright customer service or refer to the official Thermalright website.
For the complete user manual in PDF format, please refer to the Thermalright FW 240 User Manual (PDF).