Y&H SG-800W/1000W-WIFI

Contents

Y&H SG-800W/1000W-WIFI MPPT Grid Tie Micro Solar Inverter User Manual

Model: SG-800W/1000W-WIFI | Brand: Y&H

For 30-60VDC Solar Panel Input, with WiFi, IP65, Output 120V/230V Home Grid Solar Power

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Y&H SG-800W/1000W-WIFI MPPT Grid Tie Micro Solar Inverter. This device is designed to convert DC power from solar panels into AC power for injection into your home's electrical grid. It features Maximum Power Point Tracking (MPPT) for optimal energy harvesting and integrated WiFi for cloud monitoring.

Please read this manual thoroughly before installation and operation. Keep it for future reference.

2. Safety Information

WARNING! DANGER!

Failure to read and follow this user manual before operating this equipment can result in serious injury, property damage, and/or electrical shock.

  • Connect photovoltaic panel(s) ONLY to this equipment.
  • This equipment is an ON-GRID Microinverter. For proper operation, it must be connected to the power grid correctly, and the power grid must be working properly. The inverter will stop generating if the power grid stops working.
  • Do NOT exceed the PV panel(s) voltage beyond the inverter's maximum input voltage.
  • Do NOT exceed the PV panel(s) power beyond the inverter's maximum input power.
  • DC voltage sources pass through this equipment. Each circuit must be individually disconnected before servicing.
  • Do NOT cover other items on this equipment.
  • Do NOT remove the lid. Servicing must be performed by qualified service personnel.
  • When the PV array is exposed to light, it supplies DC voltage to this equipment.
  • Install the inverter away from direct sunlight and direct rain exposure.

3. Product Overview

The Y&H SG-800W/1000W-WIFI Micro Solar Inverter is a compact and efficient device for grid-tie solar applications. Below is a diagram illustrating its main components and connections.

Y&H Smart Inverter Component Diagram
Figure 1: Smart Inverter Component Diagram
This diagram shows the main parts of the inverter: Status Indicator, 2.4G Antenna, Mounting Holes, DC Input I and II (to PV Modules), AC Bus Cable (to previous inverter), WiFi Set/Reset Button, and AC Bus Cable (to next inverter/the Grid).
  • Status Indicator: Provides visual feedback on the inverter's operational status.
  • 2.4G Antenna: For WiFi communication and cloud monitoring.
  • Mounting Holes: Used to secure the inverter to a racking system.
  • DC Input I & II: Connectors for photovoltaic (PV) modules.
  • AC Bus Cable: For connecting to the AC grid or other inverters in a stackable configuration.
  • WiFi Set/Reset Button: For configuring WiFi settings or resetting the device.
  • Sticker: Contains unique ID and basic parameters for the inverter.

For single micro inverter installations, the left/right AC connectors can be cut off, or an extra male/female connector/extension cable can be purchased.

4. Specifications

The following table details the technical specifications for the Y&H SG(x)MD Series Micro Solar Inverters.

Y&H Smart Micro Inverter SG(x)MD Series User Manual Parameter Table
Figure 2: Parameter Table and Basic Structure Diagram
This image provides a comprehensive table of electrical and mechanical specifications for the SG600MD, SG700MD, SG800MD, and SG1000MD models, along with a basic structure diagram and safety warnings.
Y&H SG(x)MD Series Micro Inverter Specifications
Parameter SG600MD SG700MD SG800MD SG1000MD
Input Data (DC, PV)
Number of Input MC4 Connector2 sets
MPPT Voltage Range28V-55V
Operation Voltage Range20V-60V
Maximum Input Voltage60V
Startup Voltage20V
Maximum Input Power2*300W2*350W2*400W2*500W
Maximum Input Current2*10A2*11.66A2*13.33A2*16.66A
Output Data (AC)
Single-Phase Grid Type120V & 230V
Rated Output Power590W650W760W950W
Maximum Output Power600W700W800W1000W
Nominal Output Current @120VAC4.91A5.41A6.33A7.91A
Nominal Output Current @230VAC2.56A2.82A3.3A4.13A
Nominal Output Voltage120VAC/230VAC
Default Output Voltage Range@120VAC: 80V-160V / @230VAC: 180V-280V
Nominal Output Frequency50Hz / 60Hz
Default Output Frequency Range@50Hz: 47.5Hz-52.5Hz / @60Hz: 57.5Hz-62.5Hz
Power Factor>0.99
Total Harmonic DistortionTHD <5%
Maximum Units per Branch @120VAC4 units4 units4 units3 units
Maximum Units per Branch @230VAC8 units7 units6 units4 units
Efficiency
Peak Efficiency95%
CEC Weighted Efficiency@120VAC: 92.5% / @230VAC: 93.5%
Nominal MPPT Efficiency99.9%
Night Power Consumption<700mW
Mechanical Data
Operating Ambient Temperature Range-40°C to +65°C
Storage Temperature Range-40°C to +85°C
Dimensions (W x H x D)185mm x 180mm x 38.5mm (not include connectors and cable)
Weight1.5kg
Max Current of AC Bus Cable20A
Waterproof GradeIP65
Cooling ModeNatural Convection - No Fans
Other Features
CommunicationWIFI With Cloud Monitoring
Transformer DesignHigh Frequency Transformers, Galvanically Isolated
Integrated GroundEquipment ground is provided by the PE in the AC cable. No additional ground is required.
Protection FunctionsIsolated Island Protection, Voltage Protection, Frequency Protection, Temperature Protection, Current Protection, etc.
Design ComplianceCE etc.

5. Setup and Installation

Before beginning installation, ensure the utility voltage at the common grid connection point matches the voltage rating on your Microinverter label.

5.1. Packing List

  • Micro inverter / 1pcs
  • Mounting screws / 1pcs
  • Micro inverter User Manual / 1pcs
  • Cloud Monitoring User Manual / 1pcs
  • Antenna / 1pcs

5.2. Installation Steps

How to Install Y&H Smart Inverter Diagram
Figure 3: Installation Steps Overview
This diagram illustrates the three main installation steps: mounting the inverter, connecting DC input from solar panels, and connecting the AC output to the household outlet. It also highlights proper and improper mounting positions.
  1. Step 1: Attaching the Microinverters to the Racking

    Install the inverter on the bottom of the solar panel. Note that it must be ventilated and dry, in a cool environment. Mark the location of the Microinverter on the rack, ensuring it's clear of PV module junction boxes or other obstructions. Mount each Microinverter using hardware recommended by your module racking vendor.

    Improper Installing Position:

    • Inverter installed in an open space with water seepage and dripping. Exposure to these conditions is excluded from warranty coverage.

    Proper Installing Position:

    • Inverter installed in the position of the solar panel, where it will not have water seepage and dripping.
  2. Step 2: Connecting the Microinverter AC bus cable one by one

    Connect the two DC terminals of the PV to the inverter: positive to positive, negative to negative MC4 Connector. Ensure each MC4 branch does not exceed 400W (for 800W model) or 500W (for 1000W model). Compatible with 2pcs 400W Solar Panel (Vmp>28V, Voc≤55V). Do NOT exceed the Maximum Units per Branch.

    Solar Panel Compatibility Diagram
    Figure 4: Solar Panel Compatibility and DC Connection
    This diagram shows how to connect two solar panels to the inverter, emphasizing that each MC4 branch should not exceed 400W, with specific voltage requirements (Vmp>28V, Voc≤55V).
  3. Step 3: Connecting Microinverters to the PV Module

    Do NOT exceed PV panel(s) VOC over inverter max. input voltage.

  4. Step 4: Tighten the Bus Cable End Cap

    Securely tighten the Bus Cable End Cap at the end of the AC bus cable.

  5. Step 5: Install the AC Branch Circuit Junction Box

    Wire the conductors of the AC bus cable: L-BROWN, N-BLUE, G-GREEN&YELLOW. Connect the AC branch circuit junction box to the point of utility-grid interconnection.

    AC Bus Cable And Connectors Wiring:

    • P1 - L (BROWN)
    • P3 - N (BLUE)
    • P2 - G (GREEN&YELLOW)
  6. Step 6: Double Check Connections

    Double check that all Microinverters, connectors, and cables are correctly and well connected.

5.3. Wiring Schematics

The inverter supports various grid types. Refer to the following wiring diagrams for your specific setup.

Y&H Smart Micro Inverter SG(x)MD Series Wiring Schematic
Figure 5: Detailed Wiring Schematics
This image contains detailed wiring diagrams for various grid configurations including Single-Phase 230V, Single-Phase 120V, 2-Phase 208/240V, 3-Phase 380V, and 3-Phase 208/240V. It is crucial to follow the diagram corresponding to your local grid type.
  • Single-Phase 230V: Connect L, N, G to the grid via a breaker.
  • Single-Phase 120V: Connect L, N, G to the grid via a breaker.
  • 2-Phase 208/240V (Single-Phase 120V): Connect L1, L2, N, G to the grid via a breaker.
  • 3-Phase 380V (Single-Phase 230V): Connect L1, L2, L3, N, G to the grid via a breaker.
  • 3-Phase 208/240V (Single-Phase 120V) I & II: Connect L1, L2, L3, N, G to the grid via a breaker.

Multi-inverter Stackable Connection:

Multiple Stackable Connection Diagram
Figure 6: Multiple Stackable Connection
This diagram illustrates how multiple inverters can be connected in a stackable configuration to feed into a residential grid, emphasizing the use of a circuit breaker for the inverter AC output. It also shows a two-way AC meter and the power grid connection.

When connecting multiple inverters in a stackable configuration, the inverter AC output must use a circuit breaker.

6. Operating Instructions

  1. Step 7: Power On AC Branch Circuit Breakers

    Turn ON the AC circuit breaker on each AC branch circuit connected to a Microinverter.

  2. Step 8: Power On Main AC Breaker

    Turn ON the main AC circuit breaker of the utility-grid. Your system will begin producing power after a 30-second safety delay period.

6.1. LED Display Status

  • Green light steady: Microinverter is generating power.
  • Red flash: Microinverter is in waiting mode.
  • Red light steady: Indicates a fault condition. This could be due to:
    • Island protection
    • Over-temperature protection
    • Over/low AC voltage protection
    • Over/low DC voltage protection
    • Over/low AC frequency protection
    • General fault

7. Monitoring

The Y&H Micro Inverter features a mobile phone communication function, allowing you to monitor the working status of your inverter anytime and anywhere via a dedicated app.

Mobile Phone Monitoring Feature
Figure 7: Mobile Monitoring Interface
This image shows a user monitoring the inverter's performance via a mobile application, highlighting the convenience of cloud monitoring.

Refer to the included "Cloud Monitoring User Manual" for detailed instructions on setting up and using the WiFi monitoring feature and mobile application.

8. Maintenance

  • Regularly inspect the inverter for any visible damage or signs of wear.
  • Ensure the inverter's cooling fins are free from dust and debris to maintain optimal operating temperature. The inverter uses natural convection cooling, so airflow is crucial.
  • Check all electrical connections periodically to ensure they are secure and free from corrosion.
  • Monitor the inverter's performance via the mobile app to detect any anomalies early.
  • Do not attempt to open or repair the inverter yourself. Servicing must be performed by qualified service personnel.

9. Troubleshooting

If your inverter is not operating as expected, refer to the LED display status for initial diagnosis:

  • Red flash: The inverter is in waiting mode. This is normal during startup or if grid conditions are not met.
  • Red light steady: Indicates a fault. Check for:
    • Grid connection issues: Ensure the AC grid is active and stable.
    • Over-temperature: Check for proper ventilation and clear any obstructions around the inverter.
    • Voltage/Frequency deviations: Verify AC and DC voltages and frequencies are within specified ranges.
    • PV panel issues: Ensure solar panels are receiving adequate sunlight and are connected correctly. Check panel voltage (VOC) is not exceeding inverter limits.
  • If the issue persists after checking these points, consult the "Cloud Monitoring User Manual" for more detailed troubleshooting steps or contact customer support.

10. User Tips

  • This inverter is designed for grid-tie applications, meaning it injects power into your existing electrical grid. It is not intended for isolated, off-grid systems that require direct DC to AC conversion for a standalone sector of the house.
  • The product typically does not include a pre-attached AC plug. You will need to prepare and connect the AC cable yourself (DIY) according to your local electrical standards and the wiring diagrams provided.
  • Users have reported these units to be reliable and effective in pumping out power consistently when correctly installed.
  • If you are considering a "zero export" configuration, where no power is sent back to the grid, you may need additional equipment or specific settings. This inverter's primary function is grid-tie, so consult with a solar professional for zero export solutions.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase documentation or visit the official Y&H website.

A digital version of this user manual and other related documents can be found at: Y&H Micro Inverter User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.