Aideepen XY12522

Rate this product if you’ve used it
Contents

XY12522 CNC Adjustable Direct Current Stabilized Voltage Power Supply User Manual

Model: XY12522 | Brand: Aideepen

1. Introduction

This manual provides detailed instructions for the safe and efficient operation of your XY12522 CNC Adjustable Direct Current Stabilized Voltage Power Supply. Please read this manual thoroughly before use and keep it for future reference.

The XY12522 is a versatile DC buck power supply featuring constant voltage (CV), constant current (CC), and constant power (CW) modes. It supports firmware upgrades, MPPT solar charging, and serial communication via standard MODBUS protocol. It is designed with top-quality materials for durability and high precision.

Play video
Watch video online

Video: Demonstration of basic voltage and current setting, and display toggling.

2. Safety Precautions

  • Input Power: Do NOT connect the input to AC power, especially 220V utility.
  • Input Voltage Limit: The maximum input voltage must not exceed 145V. It is recommended to operate within 140V.
  • Polarity: Ensure positive and negative poles are connected correctly. Reversing polarity can damage the device.
  • Output Anti-Reverse Irrigation: The output is NOT anti-reverse irrigation. When connecting a battery, ensure the power supply output voltage is always higher than the battery voltage, or use a series diode for single conduction to prevent battery voltage reversal.
  • Output Reverse Connection Protection: This product has NO output reverse connection protection. Reversing battery positive and negative poles will damage the equipment.
  • Battery Charging: Battery charging requires expertise. Non-professionals should NOT charge batteries directly to prevent fire and explosion.

3. Product Features

  • Firmware Upgrade: Supports future firmware upgrades for enhanced functionality.
  • MPPT Solar Charging: Integrated Maximum Power Point Tracking for efficient solar charging.
  • Serial Communication: Supports standard MODBUS protocol for serial communication, with independent dual serial ports (TTL level and on-board 485).
  • Display: 1.8-inch all-viewing-angle VA color LCD (38x29mm) with a reasonable layout, large, full, and rounded fonts for professional display.
  • Construction: One-piece injection molded shell made of flame-retardant material for safety. Double-layer buckle design for secure circuit board fixation.
  • Durability: Display board uses immersion gold plating for anti-oxidation, better conductivity, and durability.
  • Precision: High-precision external clock crystal ensures accurate time, capacity, and energy statistics.
  • Control: Powered by a 48-pin powerful MCU controller with 64M frequency for fast computing.
  • Terminals: Upgraded PCB welded terminals (M3) for greater current and lower heat.
  • Analog Control: Supports 0.3-10V analog control, with measurement range configurable via software (available in numerical control screen mode).
  • Remote Control Options: Can connect to XY-K485X module for 485 bus control, WiFi module for APP and web-based control, or 433M wireless remote control module for multi-device synchronous control.
Internal components and communication options of the power supply

Image: Internal components and various communication options including 485, WiFi, and 433M remote control.

4. Specifications

Parameter Value
Product Name CNC DC Step-down Power Supply
Type Power Supply
Input Voltage 12.00V ~ 140.0V
Output Voltage 0 ~ 125.0V
Output Current 0 ~ 22.00A
Output Power 2000W (Peak Power)
Voltage Resolution 0.01V
Rated Capacity <40VA
Storage Data Groups 10 groups (Cd0-Cd9)
Conversion Efficiency ~95%
Output Type SINGLE
Certification CE
Package Weight 0.35 kg
Package Dimensions (L x W x H) 17 cm x 10 cm x 6 cm
Product and package dimensions

Image: Product size (bare board: 119x67.3mm, display unit: 86x50x40mm, recommended opening: 81.6x40.6mm) and package size (172x95x60mm).

5. Package Contents

  • Package A:
    • Adjustable power supply x1
    • Meter x1
    • Cable x2
  • Package B:
    • Adjustable power supply x1 (base plate can be used independently)

6. Setup

6.1. Bare Board Usage

The bare board can be used independently. When purchasing a bare device, switches, potentiometers, and dial switches will be welded on. If a set with a screen meter is purchased, they are not welded by default.

XY12522 Bare board with communication interfaces

Image: XY12522 Bare board showing output voltage 0-125V, output current 0-22A, independent dual serial ports, TL level communication, and on-board 485 communication.

6.2. MPPT Solar Charging Setup

An external temperature probe can be connected for over-temperature protection. Attach the external temperature probe to the battery, and charging will automatically stop if the battery overheats. The battery icon will display on the screen when connected.

MPPT solar charging setup with external temperature probe

Image: MPPT solar charging setup with external temperature probe and NTC temperature probe interface.

6.3. Communication Options

  • 485 Bus Control: Connect to an XY-K485X module for 485 bus control. Onboard 485 communication interface allows for convenient long-distance multi-machine control.
  • WiFi Module: Connect a WiFi module to enable remote control via a mobile APP (Android/iOS) and web-based networking control.
  • Infrared Remote Control: Connect to an infrared receiver module for efficient and fast infrared remote control.
  • 433M Wireless Remote Control: A 433M wireless remote control module can be accessed for synchronous control of multiple devices in any direction.
485 bus control diagram

Image: Diagram illustrating 485 bus control for multiple power supply units.

Network control diagram with Sinilink Cloud

Image: Network control diagram showing LAN penetration, real-time communication, remote control via external network, and Sinilink Cloud support for email notification and cloud record.

7. Operation

7.1. Key Function Introduction

Key function introduction diagram

Image: Diagram labeling the VSET, SW, I-SET, Encoder, and Power buttons and their short/long press functions.

  • VSET Button: Short Press: Set voltage (CV). Long Press: Enter or exit the data group UI.
  • SW Button: Short Press: Switch between input/output voltage or shift. Long Press: Enter or exit the system settings UI.
  • I-SET Button: Short Press: Set current (CC). Long Press: Enter or exit the data group settings UI.
  • Encoder Button: Short Press: Switch between displaying power (W), capacity (Ah), energy (Wh), time (h), temperature (°C) in rotation. Long Press: Turn on/off the key lock.
  • Power Button (ON/OFF): Short Press: Turn on/off the power output. Long Press: Reset capacity (Ah) / energy (Wh) / time (h) UI.

7.2. Setting Voltage and Current

  1. On the main UI, short press the VSET button to set the voltage. The LCD will display "SET" in the lower row, and "CV" will flash, indicating the voltage setting position is selected and blinking.
  2. Short press the SW button or the encoder button to switch the voltage setting position.
  3. Adjust the value by rotating the encoder.
  4. After setting, short press the VSET button to exit and save.
  5. To set the current, short press the I-SET button. The setting steps are the same as for voltage.
Instructions for setting voltage and current

Image: Visual guide for setting voltage (CV) and current (CC) values.

7.3. Quick Setting of Voltage or Current

In the system parameter settings UI, set the parameter FET to CV or CC. Rotate the encoder on the main UI to enter the voltage or current setting UI. Rotate the encoder to quickly set the voltage or current.

7.4. Input/Output Voltage Display

On the main UI, press the SW button briefly to switch between input and output voltage displays.

7.5. Checking Power/Capacity/Energy/Time/Temperature

On the main UI, press the encoder button briefly to switch between displaying power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C) in rotation.

Display modes for input/output voltage, power, capacity, energy, time, and temperature

Image: Display modes for input/output voltage, power (W), capacity (Ah), energy (Wh), time (h), and temperature (°C), and key lock function.

7.6. Key Lock

On the main UI, press and hold the encoder button for 2 seconds to lock the set voltage and current to prevent misoperation. Press and hold the encoder button for 2 seconds again after locking to unlock.

7.7. System Parameter Settings (Long Press SW)

Press and hold the SW button on the main interface to enter the settings menu. Use VSET to select the next parameter and I-SET to select the previous parameter. After completing settings, press and hold SW/encoder button to exit.

System Parameter Settings for Beeper and LCD Brightness

Image: System Parameter Settings for Beeper Enable (bEP) and LCD Brightness Adjustment (b-L).

System Parameter Settings for C-F, FET, and Add

Image: System Parameter Settings for C-F (Celsius/Fahrenheit), FET (Quick Adjustment of Voltage, Current, Power), and Add (Power Supply Address).

System Parameter Settings for Zero, CLOF, POFF, RET

Image: System Parameter Settings for ZERO (Current Zero Calibration), CLOF (Force Power Output Off When Switching Data Sets), POFF (Shutdown Function), and RET (Restore Factory Settings).

System Parameter Settings for bRE, PPT, CW

Image: System Parameter Settings for bRE (Communication Baud Rate), PPT (MPPT Solar Charging), and CW (Constant Power ON/OFF).

System Parameter Settings for bCH, bTF

Image: System Parameter Settings for bCH (Battery automatic charging threshold) and bTF (Charge Cutoff Current).

System Parameter Settings for WIFI Config, AnA, UER

Image: System Parameter Settings for WIFI Config (pairing mode), AnA (Analog Control Voltage Range), and UER (Firmware Version Number).

Available System Parameters:

  • bEP (Beeper Enable): Rotary encoder to turn on/off the beeper. OFF disables keystroke tones and alarms.
  • b-L (LCD Brightness Adjustment): Rotary encoder to adjust brightness (1-5 levels, default 5).
  • C-F (Celsius/Fahrenheit): Rotary encoder to select 'C' or 'F'.
  • FET (Quick Adjustment of Voltage, Current, or Power): Rotary encoder to select CV/CC/OFF/CP.
  • Add (Power Supply Address): Press SW/encoder to select bit, rotate to adjust value (1-247, default 001). For serial communication.
  • bRE (Communication Baud Rate Settings): Rotary encoder to set values from 0-8 (e.g., 0:9600, 6:115200). Default is 115200 (level 6).
  • PPT (MPPT Solar Charging Settings): Rotary encoder to turn on/off MPPT function. Adjust coefficient value (0.75-0.85, default 0.8).
  • CW (Constant Power CW ON/OFF): Enable/disable constant power function. Press I-SET to modify value.
  • bCH (Battery Automatic Charging Threshold): Press power button to turn on/off. When battery voltage falls below threshold, power output activates charging.
  • bTF (Charge Cutoff Current): Press power button to turn on/off. After enabling, press SW or encoder to select digit, rotate to adjust value in mA.
  • ZERO (Current Zero Calibration): If small current (<100mA) without load, press and hold power button to calibrate zero point. Do not connect load during calibration.
  • CLOF (Force Power Output Off When Switching Data Sets): ON: Power turns off when switching data sets to prevent high voltage damage. OFF: Power state maintained.
  • POFF (Shutdown Function): ON: Press and hold power key for 5 seconds to shut down. Click power key to start up. OFF: Disable shutdown.
  • RET (Restore Factory Settings): Press and hold power button until it stops blinking to restore factory settings.
  • WIFI Config (Need WF-POW module): Modify pairing mode with encoder. Displays Invalid Wifi, Touch Pair, AP Pair, Connect Router, NetWorking.
  • AnA (Analog Control): Adjustable analog voltage range (2-10V).
  • UER (Firmware Version Number): Displays current firmware version. Supports upgrades.

7.8. Data Group Function (Long Press VSET)

This product has 10 data groups (Cd0 to Cd9). Press and hold the VSET button to access the data group UI. Rotate the encoder to call up the corresponding data group UI.

You can press VSET/I-SET briefly to switch between constant voltage (CV) and constant current (CC) settings. It supports quick viewing and modification of voltage and current in the data group, as well as SW shift operation.

After confirming the data group, press and hold the VSET/SW button or press the encoder button briefly to select the desired data group.

Data Group Function UI

Image: Data Group Function UI, showing how to set voltage, current, and select data groups (Cd0-Cd9).

Set UI Parameter Settings within Data Groups

Image: Detailed Set UI Parameter Settings within Data Groups, including input undervoltage protection, output overvoltage protection, output overcurrent protection, output overpower protection, overcapacity protection, overenergy protection, overtime protection, overtemperature protection, and external overtemperature protection.

7.9. CV/CC/CW Functions

Constant Voltage (CV) and Constant Current (CC)

When the constant power function is not enabled, the power supply operates in CV and CC modes, automatically switching based on the load:

  • If load current is less than the set constant current, the power supply is in CV mode. Output voltage is the set CV value, and current is adaptive.
  • If load current exceeds the set constant current, the power supply enters CC mode. Output current is the set CC value, and voltage is adaptive.

Constant Power (CW)

When the constant power function is enabled:

  1. The constant current value defaults to maximum.
  2. The constant voltage value (CV) serves as the initial voltage (set to a reasonable value based on conditions).
  3. After power-on, the equivalent resistance (R=U/I) of the load is calculated.
  4. The corresponding voltage is calculated based on the set constant power value using P=U²/R.
  5. The constant power point algorithm automatically tracks, achieving constant power.

Constant Power Switch and Constant Power Value Setting:

  1. Press and hold SW on the main UI to enter system settings.
  2. Press I-SET/VSET briefly to switch to the "-CP-" constant power switch option. Press ON to enable, OFF to disable.
  3. After enabling constant power, press I-SET briefly on the main interface to modify the constant power value.
Product UI function details for CV, CC, CW

Image: Product UI function details showing displays for Constant Voltage (CV), Constant Current (CC), and Constant Power (CW) modes, including output voltage, current, power, capacity, energy, time, and temperature.

8. Calibration

If the output voltage or current is inaccurate, you can calibrate it. Do NOT connect any load during calibration.

8.1. CLU Setting (Calibrate Output Voltage)

  1. Press and hold the power button to start calibration. "01" will display.
  2. Measure output voltage with a high-precision multimeter. Input actual voltage into the third line (SW shift supported).
  3. Press power button briefly for the second step. "02" will display.
  4. Repeat step 2.
  5. Press power button again. "03" will display. Wait for calibration. "SUC" for success, "ERR" for failure.

8.2. CLA Setting (Calibrate Output Current)

  1. Connect a multimeter (current mode) or electronic load (set to max range) directly to the output terminal.
  2. Press and hold the power button to start calibration. "01" will display. Input actual current from multimeter/load into the third line (SW shift supported).
  3. Press power button briefly for the second step. "02" will display.
  4. Repeat step 2.
  5. Press power button again. Wait for calibration. "SUC" for success, "ERR" for failure.

Note: If calibration fails, try again. To exit calibration accidentally, press and hold the power button; parameters will not be saved.

Calibration instructions for voltage and current

Image: Detailed instructions for CLU (Calibrate Output Voltage) and CLA (Calibrate Output Current) settings.

9. User Tips

  • The color screen is highly praised for its clarity and readability.
  • For basic current and voltage controls, be aware that it might require a few extra clicks compared to simpler models.
  • The device is capable and suitable for use as a portable power supply.
  • Always test under load to confirm performance for your specific application.

10. Troubleshooting

  • Device Not Powering On: Ensure input voltage is within the specified range (12-140V) and connections are secure.
  • Inaccurate Readings: Perform voltage (CLU) and current (CLA) calibration as described in Section 8.
  • Unexpected Shutdown: Check POFF settings in system parameters. Ensure no over-temperature or over-current protection is triggered.
  • Communication Issues: Verify wiring for 485 or WiFi modules. Check baud rate settings (bRE) if using serial communication.
  • Battery Charging Problems: Review bCH (charging threshold) and bTF (charge cutoff current) settings. Ensure proper polarity and output voltage is higher than battery voltage.

11. Maintenance

  • Keep the device clean and free from dust and moisture.
  • Ensure adequate ventilation, especially during high-power operation, to prevent overheating.
  • Avoid exposing the device to extreme temperatures or direct sunlight.
  • Regularly check all connections for tightness and signs of wear.
  • If the device requires cleaning, use a soft, dry cloth. Do not use liquid cleaners.

12. Warranty and Support

For any issues not covered in this manual, please contact your retailer or the manufacturer's customer support for assistance. Refer to the official product page for any available PDF user manuals or additional documentation: View User Manual (PDF)


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?