Introduction
The WenQia WQ371 is a versatile wireless control system designed to automate appliances based on the open or closed status of a door or window. It consists of a magnetic contact sensor and a wireless receiver switch. This manual provides detailed instructions for installation, operation, and maintenance to ensure optimal performance and safety.
Package Contents
Please check the package for the following items:
- 1x Wireless Receiver Switch
- 1x Magnetic Door/Window Sensor
- 1x 23A 12V Alkaline Battery (for sensor)
- 2x Double-sided Adhesive Tapes
- 2x Screws with Wall Plugs

Description: Image showing the wireless receiver, magnetic sensor, 23A 12V battery, two pieces of double-sided adhesive tape, and two screws with wall plugs, which are all included in the product package.
Specifications
| Brand Name | WenQia |
| Model Number | WQ371 Door Sensor Light switch |
| Item Type | SWITCHES |
| Switch Type | Push Button Switch / 433Mhz Remote Control |
| Material | Plastic |
| Is Smart Device | No |
| Origin | Mainland China |
| Certification | RoHS, LVD, CE |
| Warranty | 1 Year |
| Input Voltage | AC 85V-240V |
| Output Voltage | AC 85V-240V |
| Max Current | 10A (Receiver) |
| RF Frequency | 433MHz |
| Receiving Range | Up to 100m (theoretical), Open space > 50 meters |
| Receiving Sensitivity | >97dbm |
| Working Temperature | -30 ~ +80 °C |
| Quiescent Current | <5MA |
| Matching Mode | Intelligent Learning code 1527 |
| Storage Capacity | Up to 20 remote controls |
| Remote Operating Modes | Momentary, Toggle, Latched |
Setup
1. Sensor Battery Installation
- Gently open the casing of the magnetic sensor unit.
- Insert the provided 23A 12V alkaline battery, ensuring the correct polarity (+/-).
- Close the sensor casing securely.

Description: Image showing the internal components of the magnetic sensor, including the 23A 12V battery, a power ON/OFF switch, and a mode selection switch labeled M1/M2.
2. Receiver Wiring
WARNING: Ensure the main power supply is turned OFF at the circuit breaker before performing any wiring to prevent electric shock.
- Connect the AC power supply (Live and Neutral wires) to the terminals labeled INPUT L and INPUT N on the receiver.
- Connect your appliance (e.g., light, fan, extractor hood) to the terminals labeled OUTPUT L and OUTPUT N on the receiver.

Description: Image displaying the smart switch receiver with its wiring terminals clearly marked for AC INPUT (L, N) and OUTPUT (L, N). A diagram illustrates connecting the receiver to a power source and a light bulb. The receiver specifications are visible: RF:433Mhz, Input:AC85-240V 50/60Hz, Maxload:10A.
3. Sensor Placement
- Mount the larger main sensor unit on the fixed part of the door or window frame.
- Mount the smaller magnetic strip on the moving part of the door or window.
- Ensure that when the door/window is closed, the main sensor unit and the magnetic strip are aligned and in close proximity (within 1cm) for proper detection.
- Use either the provided double-sided adhesive tapes or screws for secure mounting.

Description: Two diagrams illustrating the function of the door/window sensor. The top diagram shows that when a window is opened, the sensor triggers an extractor hood to begin working. The bottom diagram shows that when the window is closed, the sensor signals the extractor hood to stop working.
4. Antenna Adjustment
For better signal reception, gently stretch the antenna on the receiver to its full length.
5. Operating Mode Selection (Sensor)
Inside the sensor unit, there is a switch labeled M1/M2. This switch determines how the sensor triggers the receiver:
- M1 Mode: When the door/window is Open, the connected appliance will Turn ON. When the door/window is Close, the appliance will Turn OFF.
- M2 Mode: When the door/window is Open, the connected appliance will Turn OFF. When the door/window is Close, the appliance will Turn ON.
6. Receiver Pairing (Matching Signal)
The receiver supports three operating modes. You must clear any previous pairings before setting a new mode.
To Clear All Paired Signals:
- Press the learning button on the receiver 8 times. All previously paired sensors will be cleared.
To Pair in Toggle Mode:
- 1. Press the learning button on the receiver 2 times. Wait for 3 seconds.
- 2. Trigger the sensor (e.g., open or close the door/window). The pairing is successful.
- Behavior: Each trigger from the sensor will toggle the appliance's state (ON to OFF, or OFF to ON).
To Pair in Momentary Mode:
- 1. Press the learning button on the receiver 4 times. Wait for 3 seconds.
- 2. Trigger the sensor (e.g., open or close the door/window). The pairing is successful.
- Behavior: The appliance will remain ON only while the sensor is triggered (e.g., door is open). It turns OFF when the sensor is untriggered (door is closed).
To Pair in Latched Mode:
- 1. Press the learning button on the receiver 3 times. Wait for 3 seconds.
- 2. Trigger the sensor in its first state (e.g., open the door). Wait for 3 seconds.
- 3. Trigger the sensor in its second state (e.g., close the door). The pairing is successful.
- Behavior: One sensor state (e.g., open) will turn the appliance ON, and the other sensor state (e.g., close) will turn it OFF.
Operating
Once the sensor is installed, the receiver is wired, and both are paired in the desired mode, the system will operate automatically. The appliance connected to the receiver will respond according to the selected M1/M2 mode on the sensor and the pairing mode set on the receiver.
For example:
- If the sensor is set to M1 Mode (Open-ON, Close-OFF) and the receiver is in Toggle Mode, opening the door will turn on the light. Closing the door will turn it off.
- If the sensor is set to M2 Mode (Open-OFF, Close-ON) and the receiver is in Toggle Mode, opening the door will turn off the light. Closing the door will turn it on.
Description: This video demonstrates the two operating modes (M1 and M2) of the magnetic sensor. It shows how the connected light bulb turns on and off based on the sensor's state (open/close) and the selected mode. M1 mode turns the light on when open and off when closed. M2 mode turns the light off when open and on when closed.

Description: An illustration showing the wireless signal range of 100 meters, demonstrating its ability to pass through walls. It also depicts various household scenarios where the sensor can be used, such as in bedrooms, living rooms, and kitchens, indicating its versatility for different applications.
Maintenance
1. Battery Replacement
Replace the 23A 12V battery in the magnetic sensor when you notice a decrease in performance, unreliable operation, or if the remote control voltage is low. Refer to the