SZBJ VC6233A Digital LCR Meter User Manual

Model: VC6243A+ / BM4070

1. Introduction

This manual provides detailed instructions for the operation and maintenance of your SZBJ Digital LCR Meter, model VC6243A+ (also referred to as VC6233A or BM4070). This specialized digital instrument is designed for accurate measurement of inductance, capacitance, and resistance. It features a 3½ digit liquid crystal display, a dual-slope A/D converter core, and large-scale integrated circuits, ensuring high performance and ease of use.

Front view of the SZBJ VC6243A+ LCR meter
Figure 1: Front view of the SZBJ VC6243A+ LCR meter, highlighting its multifunctional capabilities for inductance, capacitance, resistance, and diode measurements.

The meter is capable of:

  • Inductance Measurement
  • Capacitance Measurement
  • Resistance Measurement
  • Diode Measurement

2. Safety Information

Please read the following safety notes carefully before using the instrument to prevent electric shock or damage to the meter:

  • Do Not Input Voltage: Never input AC or DC voltage into the meter's terminals.
  • Discharge Capacitors: When measuring capacitance, ensure the capacitor is fully discharged before connecting it to the meter. Failure to do so can cause electric shock or damage the instrument.
  • Remove Test Leads: Always remove the test leads from the test points before changing the function switch.
  • Select Correct Function: Ensure you have selected the appropriate measurement function (L, C, R, Diode) to avoid misoperation and ensure safety.

3. Package Contents

Upon unpacking, please verify that all items listed below are present and in good condition:

  • SZBJ Digital LCR Meter (VC6243A+)
  • User Manual (this document)
  • One pair of Crocodile Clip Test Leads
  • Storage Bag
  • Soft Rubber Protective Sleeve

Note: A 9V laminated battery (6F22 type) is required for operation and is NOT included in the package.

Contents of the SZBJ VC6243A+ LCR meter package
Figure 2: Contents of the SZBJ VC6243A+ LCR meter package, including the meter, user manual, storage bag, and test leads (crocodile clips).

4. Setup and Initial Use

4.1. Battery Installation

The meter requires one 9V laminated battery (6F22 type).

  1. Locate the battery compartment on the back of the meter.
  2. Open the battery cover.
  3. Connect a 9V battery to the battery clip, observing correct polarity.
  4. Place the battery into the compartment and close the cover securely.
Rear view of the SZBJ VC6243A+ LCR meter with battery compartment open
Figure 3: Rear view of the SZBJ VC6243A+ LCR meter with the battery compartment open, showing where a 9V battery (not included) is inserted.

4.2. Protective Sleeve

The meter comes with a soft rubber protective sleeve. It is recommended to use this sleeve to protect the instrument from accidental drops and impacts.

The SZBJ VC6243A+ LCR meter alongside its soft red rubber protective sleeve
Figure 4: The SZBJ VC6243A+ LCR meter alongside its soft red rubber protective sleeve, illustrating how the sleeve provides protection.

5. Operating Instructions

5.1. General Testing Notes

  • Do not apply voltage to the input sockets to avoid damaging the instrument.
  • This LCR meter is designed for measuring inductance and capacitance. It cannot be used to measure the quality factor of reactive components. When measuring inductance or capacitance that contains a resistance component, readings may be inaccurate.
  • When measuring components within a circuit, ensure the power is cut off and remove any incentives before connecting test leads.
  • For all measurements, insert the black test lead into the "-" terminal and the red test lead into the "+" terminal.
  • Avoid short-circuiting the input terminals when measuring inductance and capacitance for extended periods, as this can rapidly consume battery power and cause internal burning.

5.2. Capacitance Measurement

  1. Ensure the capacitor is fully discharged before measurement.
  2. Set the range switch to the appropriate capacitance range (e.g., 200pF, 2nF, 20nF, 200nF, 2µF, 20µF, 200µF, 2000µF).
  3. Connect the black alligator clip test lead to the "-" terminal and the red alligator clip test lead to the "+" terminal. Connect the capacitor pins to the respective input terminals.
  4. If the display shows "1", it indicates an overrange measurement. Select a higher range.
  5. If the display shows one or more zeros before the value, select a lower range to increase resolution and accuracy.

Note for Capacitance Measurement:

  • If the display is not showing zero, adjust the ZERO ADJ. knob until it shows zero.
  • Test leads introduce stray capacitance. Subtract this value from your measurement.
  • For small capacitance, use short wires to prevent stray capacitance introduction.
  • If the meter shows zero for all ranges with an open-circuit capacitor, or an unstable value at large capacitance ranges (for leaky or breakdown capacitors), the capacitor may be seriously leaky. Confirm with another instrument.

5.3. Inductance Measurement

  1. Set the range switch to the appropriate inductance range (e.g., 200µH, 2mH, 20mH, 200mH, 2H, 20H).
  2. Connect the crocodile clips to both terminals of the inductor.
  3. If the display shows "1", it indicates an overrange measurement. Select a higher range.
  4. If the display shows one or more zeros before the value, select a lower range to increase resolution and accuracy.

Note for Inductance Measurement:

  • If the inductance value is unknown, gradually increase the range from 200µH until the overload signal disappears and a normal value is displayed.
  • When using the 2mH range, short-circuit the test leads first to measure their inductance, then subtract this value from your measurement.
  • For small inductors, use short wires to prevent stray inductance introduction.
  • This instrument cannot measure the quality factor of inductors. Inductance can vary with different impedances in the same inductor, leading to incorrect readings if measuring the inductance of a resistive component.

5.4. Resistance Measurement

  1. Set the range switch to the desired resistance range position (e.g., 200Ω, 2kΩ, 20kΩ, 200kΩ, 20MΩ).
  2. Connect the crocodile clips across the resistance under measurement.
  3. If the display shows "1", it indicates an overrange measurement. Select a higher range.
  4. If the display shows one or more zeros before the value, select a lower range to increase resolution and accuracy.

Note for Resistance Measurement:

  • When measuring resistance below 200Ω, short-circuit the crocodile clips and measure their resistance value. Subtract this value from your measurement.

5.5. Diode Measurement

  1. Connect the black test lead to the "-" terminal and the red test lead to the "+" terminal.
  2. Set the range switch to the diode symbol position.
  3. Connect the test leads across the diode under testing.

Note for Diode Measurement:

  • If the input is open circuit, the instrument will display an overrange status.
  • The displayed value is the forward voltage drop. If the diode is reverse connected, it will display an overrange status.

6. User Tips

Based on user feedback, here are some tips for getting the most out of your LCR meter:

  • Discharge Capacitors: Always remember to fully discharge capacitors before measuring them to ensure safety and accurate readings.
  • Great for Amateurs: This tool is highly recommended for amateur DIY enthusiasts due to its ease of use and good value.
  • Coil Value Readings: Users have found it excellent for accurately reading coil values.
  • Check All Scales: Upon first use, it's a good practice to test all measurement scales to confirm proper functionality.
  • Value for Money: Many users find the measurements to be better than expected for the price, offering great value.

7. Maintenance

  • Internal Circuitry: The meter is a highly accurate electronic apparatus. Do not attempt to modify or change the internal circuit.
  • Back Cover: Do not operate the meter if the back cover is not properly secured.
  • Battery Replacement: Pay attention to the 9V battery status. If the battery power is low, a battery low indicator will be shown on the LCD. Replace the battery promptly with the same type (9V laminated battery, 6F22) to ensure accurate measurements.
  • Cleaning: Use a soft, dry cloth to clean the meter. Do not use abrasive cleaners or solvents.

8. Troubleshooting

ProblemPossible CauseSolution
Display shows "1"Measurement is overrange or open circuit.Select a higher measurement range. Ensure test leads are properly connected to the component.
Unstable readings (Capacitance)Capacitor is leaky or breakdown; stray capacitance.Confirm capacitor condition with another instrument. Use shorter test leads for small capacitance.
Display shows zeros for all ranges (Capacitance)Open-circuit capacitor.Check if the capacitor is faulty or not connected.
Low battery indicatorBattery power is low.Replace the 9V battery immediately.
No displayBattery dead or incorrectly installed; power switch off.Check battery, ensure correct polarity. Turn on the power switch.

9. Specifications

9.1. General Specifications

  • Display: LCD, Max. value 1999 (3½ digits)
  • Measuring Method: Double integral A/D conversion
  • Sampling Rate: 3 times per second
  • Over Range Display: "1"
  • Low Battery Indication: " " symbol
  • Functions: Auto power off, Data Hold (DH)
  • Working Temperature: 0°C to 40°C
  • Storage Temperature: -10°C to 50°C
  • Power: One 9V laminated battery (6F22)
  • Dimensions: 187mm (H) x 87mm (W) x 35mm (D)
Side-by-side view of the SZBJ VC6243A+ LCR meter showing its dimensions
Figure 5: Side-by-side view of the SZBJ VC6243A+ LCR meter showing its dimensions: 187mm height, 87mm width, and 35mm depth.

9.2. Technical Specifications (Accuracy: ±(% reading + digits))

Capacitance

RangeAccuracyResolution
200pF0.1pF
2nF1pF
20nF10pF
200nF±(2.5%+5)100pF
2µF1nF
20µF10nF
200µF100nF
2000µF±(5.0%+5)1µF

Conversion: PF=10-12F, nF=10-9F, µF=10-6F, mF=10-3F

Inductance

RangeAccuracyResolution
200µH±(3.0%+5)0.1µH
2mH1µH
20mH±(2%+5)10µH
200mH100µH
2H1mH
20H±(5%+5)10mH

Conversion: mH=10-3H, µH=10-6H

Resistance

RangeAccuracyResolution
200Ω0.1Ω
2kΩ1Ω
20kΩ±(0.8%+2)10Ω
200kΩ100Ω
20MΩ±(1.5%+5)10kΩ

Forward Voltage Drop of Diode

RangeInstructionTesting Condition
DiodeDisplay forward voltage (approximation)Forward voltage of DC: Approx. 1mA
Reverse voltage of DC: Approx. 3V

10. Warranty and Support

This product is designed for durability and performance. For specific warranty details, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your purchase receipt as proof of purchase.

For technical support or inquiries not covered in this manual, please contact the seller or manufacturer's customer service.

A PDF version of the user manual is available for download: View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.