Thank you for purchasing the ToolkitRC ST8 Multi-function Servo Tester. This device is designed for comprehensive servo testing, offering up to 28V voltage output, 8-channel signal output, current measurement, and curve display. Please read this manual carefully before use to ensure proper operation and safety.

Product Overview

  • 4 channels of programmable independent signal, 8 channels of signal output, with 1ms accuracy.
  • 4 independent current acquisition channels with curve display.
  • Multiple measurement modes: speed, count, step, and linear.
  • Outputs PWM signals with a period range of 33 to 1000 Hz.
  • Variety of signal trigger sources: internal, buttons, knobs, and external sources.
  • Measures servo response speed with 1ms accuracy.
  • External input signal supports PWM/PPM/SBUS with 1ms accuracy.
  • Drives servos with a maximum load of 100W.
  • Multi-language system with upgradeable language options.
  • Device functions as a USB flash drive for firmware upgrades by copying the upgrade file.

2. Safety Precautions

Please read and follow these safety guidelines carefully to prevent injury or damage to the device.

  1. The ST8 accepts an input voltage of 7-28V. Always ensure the power supply voltage is consistent and pay close attention to the positive and negative polarity when connecting.
  2. The S1-S4 and S4 Ext. signal ports support a maximum current of 2A. For servos requiring higher current, connect them to the main output port to prevent internal circuit damage.
  3. The S1-S4 signal ports can only output up to 8.4V. For higher voltage requirements, use the main output port.
  4. Do not use this product in environments with high heat, humidity, flammable materials, or explosive atmospheres.
  5. Do not leave this product unattended while in use to prevent accidents.
  6. Always unplug the input power when the product is not in use.

3. Product Layout

Front Panel

ToolkitRC ST8 Front Panel Layout

Image Description: Front view of the ST8 servo tester with labeled components. Key elements include: XT60 INPUT (7-28V@MAX 10A), S5 SIGNAL PORT (Input PWM/PPM/SBUS), MICROUSB3.0 port, P1 KNOBS, KNOB(OK) (long press for settings), S1-S4 SIGNAL PORT (5.0V-8.4V@MAX 4A), S4 EXT SIGNAL PORT (5.0V-8.4V@MAX 4A), XT60 OUTPUT (5.0V-28.0V@MAX 10A), and the EXIT button (start/stop/exit).

Rear Panel

ToolkitRC ST8 Rear Panel Layout

Image Description: Rear view of the ST8 servo tester showing the main input and output ports. On the left is the INPUT DC 7-28V port. On the right are the OUTPUT XT60 port and the S1-S4 signal ports, along with the S4 Ext. port.

4. Setup

  1. Connect Power: Connect a 7-28V DC power supply to the input port on the rear of the ST8. Ensure correct polarity.
  2. Power On: The display will show the boot logo for approximately 2 seconds, accompanied by a boot sound.
  3. Main Interface: After booting, the device will automatically enter the main operating interface.

5. Operating Instructions

Basic Navigation

  • [Exit] Button: Short press to pause, start, or exit functions. Press to start PWM signal output and testing.
  • [Knob]: Rotate to move the cursor and select different channels or settings. Short press (OK) to confirm selections.
  • [Knob] (Long Press): Press and hold the [Knob] for 2 seconds to enter the system setup menu.
  • Audible Feedback: A 'didi' prompt tone will sound for successful key operations.

Main Interface Overview

After powering on and pressing [Exit], the system displays the main interface. This screen shows:

  • Top Left (e.g., 5.0V): Output voltage of the main port or PWM output port. Black indicates main port voltage is off, red indicates it's on.
  • Top Middle (e.g., Output: 20.0ms/50Hz): PWM output frequency and period.
  • Top Right (e.g., Input: 22.2V 40°C): Input voltage and motherboard temperature. Alarms and flashes red if below minimum input voltage or above safe temperature.
  • Right Side (S1, S2, S3, S4): Independent 4-channel PWM signals, distinguished by color.
  • Middle Grid: Curve display of 4 PWM output currents, color-coded for easy distinction.
  • Output Bar (Below Grid): Displays maximum current, speed, and count for each channel in real-time.
  • Lower Right (PS, PC, PE): Buttons that become selectable when button source mode is chosen.

Pause Interface

From the main interface, press [Exit] to enter the pause interface. In this mode, the current curve is paused, and the PWM signal maintains a fixed value. Rotate the [Knob] to adjust the timeline and view the saved current curve. Press [Exit] again to exit the pause interface.

Channel Settings

Select a channel on the main interface and press [OK] to access its settings.

  1. Signal Source Setting:
    Rotate the [Knob] to [Input] and press [OK] to modify the source.
    • Channel 1: Can be set to P1, S5, internal signal, or button (4 sources).
    • Channels 2-4: Can be set to P1, S5, internal signals, buttons, or Channel 1 (5 sources).
    After selecting, short press [OK] and [Exit] to apply changes.
  2. P1 Source Setting:
    When P1 is selected as the source, the PWM output is controlled by the P1 knob, and its position is displayed.
  3. S5 Source Setting:
    When S5 is selected, you can choose PWM, PPM, or SBUS signals. Input the corresponding signal on the S5 interface to display the received signal value and control PWM output.
    • PWM: Displays input PWM signal.
    • PPM: Channel can be set from CH0 to CH7.
    • SBUS: Channel can be set from CH0 to CH15.
  4. Internal Source Setting:
    When internal signal is selected, you can choose linear or phase modes, primarily for servo aging tests. These modes generate a count and stop when a set value is reached (can be turned off in system settings).
    • Linear Mode: Set step value (1-10 microseconds) and speed value (1-10 milliseconds).
    • Phase Mode: If PC point is not enabled, it's a second-order mode (jumps between PS and PE values at 1-second intervals). If PC point is enabled, it's a third-order mode (jumps between PS, PC, and PE values at 1-second intervals). This mode helps measure servo response speed.
  5. Key Setting:
    When 'button' is selected as the signal source, the main interface displays PS, PC, PE buttons. Move the cursor to these buttons and short press [OK] to output the corresponding PWM value. The time to turn the angle can be measured and displayed.
  6. S1 Source Setting:
    If S2, S3, or S4 signal sources are set to S1, they will follow S1's settings and output the same PWM value.
  7. Output Source Setting:
    Move the cursor to the [Output] position to set the range of the PWM output signal with 1 microsecond accuracy. In button source and internal source stage modes, you need to set the PC value.

System Settings

From the main interface, press and hold [OK] for 2 seconds to enter the system settings. Rotate the [Knob] to navigate and adjust settings:

SettingDescription
CycleOutput period of the PWM signal, ranging from 1ms to 30ms.
VoltageOutputMain port output voltage (11 gears: Off, 5V, 6V, 7.4V, 8.4V, 12V, 14V, 15V, 16V, 18V, 24V, 28V). If Off, PWM output is 5V (15W max). For 5.0V-8.4V, main and PWM ports match. For 12V-28V, main port is set, PWM port is 5V.
CycleCountWhen using internal signal source, sets the number of work times before operation stops.
LowestInputBelow this voltage, the device will stop main port output.
SafeTemperatureAbove this temperature, the device will stop main port output.
BacklightBacklight brightness level (1-10).
BuzzerBuzzer tone (can be set to off).
LanguageSystem display language (English, Chinese).
ThemeStyleColor style of the system interface (bright, dark).
KNOBCalibrateCalibrates the P1 knob's maximum and minimum values.
CycleCountClearClears the count under the internal source.
DefaultRestores all settings to factory defaults.

6. Maintenance

Firmware Upgrade

To upgrade the firmware:

  1. Connect the ST8 to your computer using the USB cable provided.
  2. Your computer will recognize the device as a USB flash drive named 'Toolkit'.
  3. Download the latest upgrade file (e.g., app.upg) from the official ToolkitRC website (www.toolkitrc.com).
  4. Copy and overwrite the existing firmware file on the 'Toolkit' USB flash drive with the downloaded upgrade file.

General Care

  • Keep the device dry and away from moisture.
  • Clean the device with a soft, dry cloth. Do not use harsh chemicals or solvents.
  • Store in a cool, dry place when not in use.

7. Troubleshooting

  • Device Not Powering On: Ensure the input voltage is within the 7-28V range and that the power supply is connected with correct polarity.
  • No Signal Output: Check the channel settings, ensure the correct signal source is selected, and verify all connections to the servo.
  • Overload Warning: If the device displays an overload warning, reduce the load on the output or adjust the 'VoltageOutput' setting to match the servo's requirements. Ensure the main port power is sufficient for the load.
  • Temperature Alarm: If a temperature alarm occurs, disconnect power and allow the device to cool down in a well-ventilated area before resuming operation.
  • Incorrect Readings: Ensure all connections are secure and that the device is properly calibrated (e.g., KNOBCalibrate).

8. User Tips

Based on user experiences, here are some tips for getting the most out of your ST8 servo tester:

  • Prevent Overloading: Always select the appropriate output voltage in the system settings to match your servo's specifications and avoid overloading.
  • Portable Power: A lithium-ion battery with an XT60 connector can be conveniently used as a power supply for field testing.
  • Optimize Testing: Utilize the ability to choose the operating frequency to test servos under various conditions.
  • Monitor Consumption: The device immediately displays servo current consumption (mA), which is excellent for analyzing servo health, finding binding issues, and checking performance.
  • Comprehensive Analysis: Use the graphical display and detailed information to thoroughly analyze servo consumption, identify potential problems, and test performance.
  • Versatile Use: The ST8 works effectively with a wide range of servos, from micro servos to those with high torque.

9. Specifications

FeatureSpecification
Input Voltage7-28V @ MAX 10A
Main Output Port5.0V-28.0V @ MAX 10A
Signal Port (S1-S4)5.0V-8.4V @ MAX 4A
Output Voltage (S4 Ext.)5.0V-8.4V @ MAX 4A
Output Signal (S1-S4)100us-2900us @ 33-1000Hz
Output Signal (S5 PWM)500us-2500us
Output Signal (S5 PPM)8CH
Output Signal (S5 SBUS)16CH
P1 Rotation Range1000us-2000us
MicroUSBUpgrade @ USB3.0
LCD Display2.4 inch TFT RGB 320*240 resolution
Product Size99mm * 68mm * 26mm
Product Weight140g
Packing Size105mm * 80mm * 45mm
Packing Weight160g

10. Warranty and Support

For warranty information, technical support, or further inquiries, please refer to the official ToolkitRC website or contact your point of purchase. The latest user manual in PDF format may also be available for download on the manufacturer's website: www.toolkitrc.com.

© 2024 ToolkitRC. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.