1. Product Description
The Sovol SH02 Filament Dryer is designed to keep 3D printer filaments dry, improving print quality and preventing issues caused by moisture absorption. It features a fast heating system, excellent sealing performance, and an easy-to-use interface.
Product Overview
The device includes a ventilation shaft, discharge holes, snap locks for the lid, a digital screen for controls, a power switch, and a power cord interface.

Figure 1: Front view of the Sovol SH02 Filament Dryer with its digital display.
2. Setup Instructions
2.1 Power Connection
- Plug one end of the power cord into a suitable power socket.
- Connect the other end of the power cord into the power interface at the back of the drying box.
- Press the main power switch located at the back of the drying box.
- Once powered on, the standby start button on the right side of the screen will light up, indicating the drying box is in standby mode.
2.2 Loading Filament
- Open the top cover of the drying box.
- Place the filament spool(s) inside the drying box. The SH02 can accommodate two rolls of consumables (each ≤70mm width) or a single roll (≤150mm width). Ensure the filament is oriented correctly to avoid excessive friction with the filament outlet.
- Close the top cover securely using the snap locks.
2.3 PTFE Tube Installation (Optional)
If you experience issues with filament feeding smoothly during use, you can install PTFE tubes into the filament outlets:
- Locate the filament outlets on the top cover.
- Insert the sharp end of a PTFE tube (two are included) into the dry box cover, about 15mm deep, into the proper position.
- Feed the filament through the PTFE tube from the inside of the dryer. This helps guide the filament and prevents it from contacting ambient moisture before printing.

Figure 2: Detailed view of filament outlets and moisture outlet, showing PTFE tube insertion points.
Note: After use, remove and store the PTFE tubes.
3. Operating Instructions
3.1 Control Panel Overview
The control panel features a digital screen and four buttons:
- Standby Start Button (Power Icon): Turns the unit on/off from standby.
- Set Selection Key (Gear Icon): Enters and navigates through setting parameters.
- Up Button (Up Arrow): Increases the selected parameter value.
- Down Button (Down Arrow): Decreases the selected parameter value.
3.2 Screen Parameters
- Materials: Displays the currently selected filament type (e.g., PLA, PETG).
- Setting Temperature: Shows the target drying temperature.
- Current Temperature: Displays the actual temperature inside the drying chamber.
- Relative Humidity: Shows the current humidity level within the chamber.
- Time: Displays the countdown timer for the drying process.
3.3 Starting the Drying Process
- After loading filament and powering on, press the Standby Start Button for 0.5 seconds.
- The screen will illuminate, and the drying box will begin operating according to default parameters (e.g., PLA at 50°C for 8 hours).
3.4 Modifying Drying Parameters
- Press the Set Selection Key (Gear Icon) to enter the setting mode. A cursor will appear and flash next to the first adjustable parameter (Materials).
- Press the Set Selection Key again to cycle through the parameters: Materials, Setting Temperature, and Time.
- When the cursor is next to the desired parameter, use the Up or Down buttons to adjust its value.
- To confirm your settings, stop pressing buttons. After 10 seconds of inactivity, the cursor will disappear, and the system will automatically save and apply the new parameters.
Note: While in setting mode, the heating block, fan, and timer continue to operate. If the time setting is changed, the timer will reset to the new value upon exiting the setting mode.
3.5 Consumable Drying Parameter Reference
The following table provides recommended drying temperatures and times for common filament types:

Figure 3: Recommended drying temperatures and times for various filament types.
| Filament | Drying Temp | Drying Time |
|---|---|---|
| PLA | 50°C | 4-12h |
| PETG | 65°C | 4-8h |
| ABS | 60°C | 8-12h |
| TPU | 55°C | 4-8h |
| PVA | 50°C | 4-8h |
| ASA | 60°C | 8-12h |
| PA | 70°C | ≥12h |
| PP | 55°C | 4-8h |
| PC | 70°C | 8-12h |
*Recommendation: When drying and printing PLA simultaneously, a temperature setting of 45°C is recommended.
4. Maintenance
4.1 Replacement of Desiccant
The SH02 includes compartments for desiccant to help maintain a dry environment when not actively heating. Replace the desiccant as needed:
- Turn off the power to the drying box.
- Carefully open the desiccant compartment cover(s) using your fingers.
- Place new desiccant into the tank.
- Ensure the flap of the cover aligns with its notch.
- Install the cover plate securely.
5. Troubleshooting
5.1 Exception Codes
If an abnormality occurs, the drying box will sound a buzzer alarm, and an abnormality code will be displayed on the screen. The PTC heating block and fan will be forcibly shut down.
- F2: Fan rotates abnormally, fan power cord is disconnected, or motherboard 12V power supply is unstable.
- H1: PTC heating block does not heat properly.
- H2: PTC heating block heats uncontrollably.
- N1: NTC thermistor short circuit.
- N2: NTC thermistor is blocked.
- N3: NTC abnormal resistance value.
To exit the abnormal alarm state, press and hold the Standby Start Button for 0.5 seconds. The drying box will then enter standby state.
Note: If an alarm occurs, contact after-sales support for assistance.
6. Specifications
| Feature | Specification |
|---|---|
| Input Voltage | US Regulations: 100-120V 60Hz National/British/European Standard: 200-240V 50Hz |
| Rated Power | 150W |
| Filament Diameter | 1.75mm / 2.85mm |
| Maximum Consumable Capacity | Two rolls ≤70mm (width) or one roll ≤150mm (width) |
| Display Humidity Range | 0-99% |
| Display Temperature Range | 0-99°C |
| Machine Size (L*W*H) | 249mm * 175mm * 283.5mm (approx. 9.8 x 6.9 x 11.2 inches) |
| Equipment Weight | 1.5KG |

Figure 4: Dimensions of the Sovol SH02 Filament Dryer and compatible spool sizes.
7. User Tips
- Humidity Reduction: For faster and more effective drying, especially in the initial stages, consider leaving the lid slightly ajar or using a 3D-printed lid prop for the first 1-2 hours to allow moisture to escape more easily.
- Noise Level: The dryer's fan may produce a noticeable whining noise. If noise is a concern, some users have found success by printing and installing fan silencer kits (available from community platforms).
- Desiccant Effectiveness: The built-in desiccant compartments are effective for long-term storage to maintain dryness, but active heating is required for significant moisture removal from wet filament.
8. Warranty and Support
For any issues, abnormalities, or warranty claims, please contact Sovol customer support. Refer to the official user manual PDF for detailed warranty information and terms.
Official Website: sovol3d.com
Email: info@sovol3d.com