GIANTELE LA38-11X2 20X3

Contents

LA38 Rotary Switch Instruction Manual

Model: LA38-11X2 20X3

1. Product Overview

The GIANTLE LA38 Rotary Switch is an industrial switch designed to control circuit on/off or switch between different positions through a rotary action. It is widely used in various applications such as machine tools, control cabinets, automation equipment, and distribution boxes.

Key features include oil resistance, dust resistance, a high protection rating, clear operating feel, reliable contact action, and a long service life. This switch is typically available in two-position or three-position versions, with either a self-locking (maintained) function, where the switch stays in the selected position after rotation, or a self-reset (momentary) function, where the knob returns automatically to its original position when released.

Multiple LA38 Rotary Switches
Figure 1: Overview of LA38 Rotary Switches.

2. Safety Information

  • Disconnect Power: Always disconnect the main circuit power before attempting any installation or wiring.
  • Qualified Electrician: Installation and wiring must be performed by a qualified electrician to ensure safety and proper function.
  • Match Specifications: Ensure the rated voltage (Ui: 400V) and current (Ith: 10A) of the switch match the load requirements. Overloading is strictly prohibited and can lead to damage or hazards.
  • Environmental Conditions: Do not use non-protected versions of this switch in damp, dusty, corrosive gas, or flammable/explosive environments.
  • Mounting: During installation, ensure the panel cutout size meets the specified 22mm requirements. Tighten the mounting nut securely to prevent loosening.
  • Handle with Care: Do not apply excessive force when rotating the knob, as this may damage the internal contacts or the detent mechanism.
  • No Modifications: Do not disassemble or modify the internal structure of the switch.

3. Specifications

Parameter Value
Product Name Knob switch
Model Number LA38 11X2 20X3
Mounting Hole Diameter 22mm
Operation Type Self-locking / Self-reset
Contact Configuration 1NO1NC / 2NO / 2NC
Number of Gears Two gears / Three gears
Rated Insulation Voltage (Ui) 400V
Rated Thermal Current (Ith) 10A
EU LVD Voltage Below 50Vac or 75Vdc
Material Plastic
Contact Material Silver
Button Colour Black
Terminal Type Screw (4 Terminals)
Operation Temperature -25°C ~ +55°C
Certification CE
LA38 Rotary Switch Parameter Information and Dimensions
Figure 2: Detailed parameter information and dimensions for the LA38 Rotary Switch.
LA38 Rotary Switch with Short Handle
Figure 3: LA38 Rotary Switch with a short handle.

4. Setup and Installation

  1. Prepare Mounting Hole: Ensure the control panel has a 22mm diameter mounting hole.
  2. Insert Switch: Insert the switch body into the mounting hole from the front of the control panel.
  3. Secure with Nut: From the back of the panel, thread and tighten the fixing nut onto the switch body to secure it firmly.
Quick Installation Steps for LA38 Rotary Switch
Figure 4: Quick installation guide for the LA38 Rotary Switch. Step 1: Press and hold the tab, then lift the switch. Step 2: Pull out the switch from the panel.

5. Operating Instructions

5.1 Wiring

Connect the terminals correctly according to the required wiring diagram. The switch supports both normally open (NO) and normally closed (NC) contact configurations.

Wiring Diagrams for LA38 Rotary Switch
Figure 5: Wiring methods for LA38 Rotary Switch. Left: 1 Normally Open, 1 Normally Closed (1NO1NC) wiring. Right: 2 Normally Open / 2 Normally Closed (2NO/2NC) wiring.

5.2 Rotary Operation

Rotate the knob to the desired position (e.g., left, center, right). For self-locking models, the switch will remain in that position, and the corresponding contacts will be closed or opened accordingly. For self-reset (momentary) models, the knob will return automatically to the original position when released.

2nd and 3rd Gear Rotary Switch Positions
Figure 6: Illustration of 2nd gear (Left, Right) and 3rd gear (Left, Center, Right) rotary switch positions.

5.3 Contact States

The switch uses high-quality thickened contacts with low resistivity, good conductivity, and no arcing. The state of the contacts (normally closed or normally open) is indicated visually.

Normally Closed and Normally Open Contact States
Figure 7: Visual representation of Red (normally closed) and Green (normally open) contact states.

6. Maintenance

  • Regular Checks: Periodically check that the knob rotates smoothly, the contacts make good connection, and the wiring is tight.
  • Cleanliness: Keep the panel surface clean to prevent oil or debris from jamming the knob mechanism.

7. Troubleshooting

  • Switch Not Responding: Check all wiring connections for tightness and proper contact. Ensure the switch type (self-locking/self-reset) matches the intended operation.
  • Intermittent Operation: Verify that the rated voltage and current are appropriate for the load and that no overloading is occurring. Inspect contacts for any signs of wear or damage.
  • Knob Sticking/Hard to Turn: Clean the panel surface around the knob to remove any accumulated dirt, oil, or debris. Do not force the knob.
  • No Power to Load: Confirm that the main circuit power is connected and active. Check the wiring against the provided diagrams to ensure correct NO/NC contact usage.

8. User Tips

  • Verify Contact Type: Always double-check if you need Normally Open (NO) or Normally Closed (NC) contacts before wiring to ensure the switch operates as intended for your application.
  • Consider Load: While rated for 10A, some users find these switches particularly suitable for low-load applications.
  • Quality Assurance: Users frequently report that the product arrives well-packaged and in working condition, indicating good manufacturing quality.
  • Durable Construction: The switches are noted for their solid construction and spring-loaded contacts, contributing to durability.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the seller or manufacturer directly. Keep your purchase records for reference.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.