SUITU 5KW Diesel Air Heater

Contents

SUITU 5KW Diesel Air Heater User Manual

Model: 5KW Diesel Air Heater (B2010)

Versatile 3-in-1 parking heater for 12V, 24V, and 220V applications in cars, trucks, boats, and RVs.

Product Overview

The SUITU 5KW Diesel Air Heater is an upgraded, multipurpose heating and fan system designed for various vehicles and indoor spaces. It features an LCD switch and remote control for convenient operation. This robust machine offers fast turbo heat-up and a long service life of over 5000 hours.

SUITU 5KW Diesel Air Heater with accessories
Figure 1: SUITU 5KW Diesel Air Heater with included accessories and key features.
Heater unit highlighting fast heat-up and multi-voltage compatibility
Figure 2: The heater unit emphasizing fast heat-up and universal 12V/24V/220V compatibility.

Heating Principle

The cold air is drawn into the machine, heated as it passes through the radiator, and then expelled as hot air through the fan to warm the desired space.

Diagram of heating principle with labeled components
Figure 3: Diagram illustrating the heating principle and key components like the LCD switch, oil tank, air outlet, and air intake.

Setup and Installation

Before installation, ensure you have the necessary tools, including a tape measure, marker, screwdriver, drill, and hole saw. The heater can be connected to 12V, 24V, or directly to 220V sockets.

Video 1: Installation and basic operation guide for the diesel air heater.

Included Accessories

The package includes:

All included accessories for the diesel air heater
Figure 4: Display of all included accessories, such as the LCD Switch, Remote Control, pipes, silencer, and mounting hardware.
  • LCD Switch (x1)
  • Remote Control (x1)
  • Fixture Accessories Set (x17)
  • Connection Holder (x4)
  • Air Outlet Pipe (x1)
  • Intake Pipe (x1)
  • Exhaust Pipe (x1)
  • Charging cable (x1)
  • Power cord (x1)
  • Silencer (x1)
  • Air Filter (x1)
  • User Manual (x1)
  • Host (x1)

Installation Steps

  1. Prepare Tools: Gather a tape measure, marker, screwdriver, drill, and hole saw.
  2. Connect Power: The heater supports 12V, 24V, and 220V. For 220V, plug directly into a wall socket.
  3. Install Exhaust Pipe: Secure the exhaust pipe, ensuring no flammable materials are nearby. The exhaust pipe must lead outside and be installed downward.
  4. Install Intake Pipe: Connect the intake pipe to the designated port.
  5. Secure Unit: Screw the main heater unit firmly in place.
  6. Install Silencer: Attach the silencer. Its outlet should face downward or be mounted parallel to the ground.
  7. Install Air Filter: Connect the air filter to the intake pipe. Ensure there is no shielding around it.
  8. Install Outlet Pipe: Attach the outlet pipe. It should not bend at a 90° angle, and there should be no obstructions in front of it.

Operating Instructions

Panel Display in Standby Mode

After initial startup, press the confirm button once to cycle through the following displays:

  • Clock display
  • Ambient temperature display
  • Power supply voltage display
  • Gear/temperature setting display
  • Outdoor temperature display
  • Fault code display (if any)

Button Operations

Button Action (Standby Mode) Action (On Mode)
On/Off Short press to turn ON. Long press to turn OFF.
Up Temperature / Gear + Temperature / Gear + (Long press for 3 seconds to switch to Fahrenheit display)
Down Temperature / Gear - Temperature / Gear -
Confirm Cycle through displays. Cycle through displays.
Set Set parameter. Set parameter.

Remote Control Features

The remote control allows for convenient operation from up to 30 meters away.

Remote control features and range
Figure 5: Remote control highlighting features like temperature adjustment, remote start, large LCD screen, and smart thermostat.
  • Temperature adjustable
  • Remote control start
  • Large screen LCD
  • Smart thermostat
  • Control range within 30 meters

Mode Switching

  1. Panel Switching: Simultaneously press the Up/Down buttons to switch between Constant Temperature mode (displays "27 °C" and flashes) and Automatic Start/Stop mode. Press again to switch to Manual mode (displays "P-01").
  2. Remote Control Switching: If the machine is ON, press and hold the ON button on the remote control for 3 seconds to switch between Manual, Constant Temperature, or Automatic Start/Stop modes. Allow at least 3 seconds between switches.

Manual Oil Pumping

To manually pump oil (e.g., for priming):

  1. Simultaneously press the Set button and the Down button to enter the manual oil pumping interface (e.g., displays "020").
  2. Press the Set button to adjust the number (pumping time). Use the Up button to increase time and the Down button to decrease time (range: 0-999 seconds).
  3. Short press the Confirm button to start/stop pumping.
  4. Press the On/Off button to exit, or it will automatically exit after 20 seconds of inactivity.

Temperature Display Unit Switching

The default temperature display is Celsius (e.g., "27°C"). In ON mode, long press the Up button for 3 seconds to switch to Fahrenheit display (e.g., "27 °F"). All temperature-related displays will then show Fahrenheit.

Parameter Settings (Access from Standby Mode by long pressing the Set button)

The parameter setting interface allows you to configure various aspects of the heater. Use the Up/Down buttons to adjust values and the Confirm button to move to the next item.

  • Clock Setting: The initial display is "00:00". Adjust the numbers sequentially.
  • Timed Startup Setting: Set a specific time for the heater to start.
  • Timed Shutdown Setting: Set a specific time for the heater to shut down.
  • Password Entry: If prompted, enter the password using the Up/Down buttons and Confirm button.
  • P1H2 Display: This section allows configuration of voltage (12V/24V/AU), power (5KW/2KW/8KW), and pump type (16ML/22ML/28ML).
  • Auto-start Temperature Setting: In automatic start/stop mode, press the On/Off button to set the startup temperature (range: 15°C - 35°C). After returning to the main interface, use the Up/Down buttons to change the automatic shutdown temperature.

Note: After all parameter settings are complete, press the On/Off button to confirm and save the settings before exiting the menu. Settings will not be saved if automatically shut down after a timeout.

Maintenance

Regular maintenance ensures optimal performance and longevity of your diesel air heater.

  • Cleaning: Periodically clean the exterior of the heater. Ensure air intake and outlet vents are free from dust and debris.
  • Filter Inspection: Check the air filter regularly and clean or replace it as needed to maintain proper airflow.
  • Pipe Inspection: Inspect all pipes (exhaust, intake, outlet) for any blockages, damage, or loose connections.
  • Fuel System: Ensure the fuel tank is clean and free of contaminants. Use clean diesel fuel.
  • Electrical Connections: Verify all electrical connections are secure and free from corrosion.

Troubleshooting

The heater's display will show error codes if a fault occurs. Refer to the table below for common issues and solutions.

Screen Off Instructions

  • Standby Mode: The screen will turn off completely if no button is pressed for more than 5 minutes.
  • On Mode: The screen will turn off if no button is pressed for more than 5 minutes. When off, a breathing beep is played and '8' appears. Press any button to wake the screen.

Fault Codes and Solutions

Code Fault Description Solution
E-01 Under voltage Voltage too low (e.g., <18V for 24V system, <10V for 12V system). Check power supply.
E-02 Over voltage Voltage too high (e.g., >32V for 24V system, >17V for 12V system). Check power supply.
E-03/F1 Spark plug short circuit Inspect spark plug and wiring for shorts.
E-03/F2 Spark plug open circuit Inspect spark plug and wiring for open circuits.
E-04/F1 Oil pump short circuit Inspect oil pump and wiring for shorts.
E-04/F2 Oil pump open circuit Inspect oil pump and wiring for open circuits.
E-05 Overheating Outdoor temperature >260°C. Check for blocked air inlet/outlet.
E-06/F1 Fan short circuit Inspect fan and wiring for shorts.
E-06/F2 Fan open circuit Inspect fan and wiring for open circuits.
E-06/F3 Fan speed not recognized by Hall sensor Check fan sensor connection and functionality.
E-07 Disconnection Communication cable or plug between On/Off button and controller is open or virtually connected.
E-08 Flameout Check for air/wax blockage in oil circuit, poor oil supply.
E-09/F1 Cabinet temperature sensor short circuit Inspect cabinet temperature sensor and wiring for shorts.
E-09/F2 Cabinet temperature sensor open circuit Inspect cabinet temperature sensor and wiring for open circuits.
E-10 Ignition failure If ignition fails twice, check for blocked oil circuit, non-smooth oil inlet, stuck oil pump, or blocked volatile net due to oil problems.
E-11 Ambient temperature sensors Ambient temperature sensors are open or short-circuited.
E-12 Controller overheating Controller temperature >100°C. Check for blocked air inlet/outlet or damaged ECU.

Specifications

Detailed technical specifications for the SUITU 5KW Diesel Air Heater.

Heater dimensions and specifications table
Figure 6: Product dimensions and a table of detailed specifications.
Feature Specification
Brand Name SUITU
Item Type Heating & Fans
Power (W) 5000W (Thermal power: 2000W-8000W)
Voltage 12V / 24V / 220V Universal
Fuel Diesel oil
Fuel Consumption (L/h) 0.1-0.2 / 0.11-0.35
Rated Power (W) 15-90
Switch Type LCD Switch
Lower Voltage Limit About 10.5V
Upper Voltage Limit 12V-220V
Overheat Protection 180 °C
Operating Temperature -50 °C ~ +50 °C
Special Features Upgraded diesel parking heater
Durability Service life more than 5000 hours
Multipurpose Use All kinds of cars, trucks, work vehicles, ships, indoor
Origin Mainland China

Package Dimensions and Weight

  • Length: 47 cm
  • Width: 38 cm
  • Height: 32 cm
  • Weight: 7.816 kg

User Tips

  • Automatic Shutdown: The heater will automatically shut down if the ambient temperature exceeds the set shutdown temperature. It will automatically restart when the ambient temperature drops below the set start temperature. This feature helps maintain a consistent environment and saves fuel.
  • Priming the Fuel System: If the heater is new or has run out of fuel, use the manual oil pumping function to prime the fuel system before starting to ensure smooth operation and prevent ignition failures.
  • Exhaust Placement: Always ensure the exhaust pipe is directed downwards and away from any flammable materials or enclosed spaces to prevent carbon monoxide buildup and fire hazards.

Warranty and Support

For detailed warranty information and customer support, please refer to the official documentation provided with your product or contact the manufacturer directly. A digital version of the user manual is available for reference:

View User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.