1. Introduction
This programmable electronic timer is designed for precise timing control in various applications. It can be used for street lamps, neon lights, advertising signboards, door head lights, rice cooker timing, electric fans, TVs, computers, water pumps, refrigerators, air conditioners, and even for school bell systems. The timer supports daily or weekly programming with up to 18 ON/OFF settings.
Figure 1: Front view of AHC30A (left) and AHC30B (right) timers.
2. Safety Information
- Ensure all wiring is performed by a qualified electrician and complies with local electrical codes.
- Do not exceed the rated load capacity of the switch (30A resistive load for direct control). For loads exceeding 4.5kW, use external AC contactors.
- Do not operate the device in humid, corrosive environments, or areas with high metal content gas, oil, or water, as this may affect normal operation and device lifespan.
- Always disconnect power before installation, maintenance, or troubleshooting.
3. Technical Data (Specifications)
| Feature | Specification |
|---|---|
| Brand Name | DIANQI |
| Model Number | AHC30A, AHC30B |
| Theory | Electronic |
| Type | Mini |
| Use | Timer Switch |
| Origin | Mainland China |
| Certification | CE, RoHS |
| Working Voltage | AC220V, AC110V, DC12V, DC24V, DC48V |
| Hysteresis | ≤ 1 sec/day (at 25°C) |
| Minimum Interval | 1 minute |
| Timing Mode | Daily or Weekly |
| ON/OFF Operation | 18 ON & 18 OFF |
| Power Consumption | 7.5VA (max) |
| Service Life | Mechanically: 107, Electrically: 105 |
| Output Mode | AHC30A: 1 ON and 1 OFF (1NO1NC), AHC30B: Active Output (1NO) |
| Countdown | 1 second - 99 minutes 59 seconds |
| Load Capacity | Resistive load: 30A |
| Switching Contact | 1 changeover switch |
| Power Reserve | 3 years (lithium battery) |
| Ambient Temperature | -10 to +40°C |
| Ambient Humidity | 35-85%RH |
| Weight | Approx. 150g |
| Battery Included | Yes |
| High-concerned chemical | None |
| Contact Choose | 1NO 1NC / 1NO |
Figure 2: Timer dimensions (measurements in mm).
4. Product Overview
The timer features an LCD display for time and program status, along with several buttons for setting and manual control. It is designed for DIN rail mounting.
Figure 3: Close-up of the timer's display and control buttons.
Figure 4: Back view of the timer, revealing the CR2032 battery compartment.
5. Setup
5.1 Initial Setup
- Reset: When using the timer for the first time, press the RESET key (small hole next to the 'P' button) using a pointed object.
- Time Mode (12h/24h): The timer defaults to 24-hour mode. To switch to 12-hour mode, press and hold the 'd+' button for 5 seconds. The LCD will display 'AM' or 'PM'. To return to 24-hour mode, press and hold 'd+' for 5 seconds again.
- Adjust Local Time:
- Press 'P' to enter time setting mode.
- Press 'D+' to adjust the week.
- Press 'H+' to adjust the hour.
- Press 'M+' to adjust the minute.
5.2 Wiring Instructions
Proper wiring is crucial for safe and correct operation. Refer to the diagrams below for different configurations. Ensure power is disconnected before wiring.
Figure 5: Comparison of 1NO 1NC (AHC30A) and 1NO (AHC30B) wiring for direct load control.
- 1NO 1NC (AHC30A): Controls the opening and closing of a circuit without load.
- 1NO (AHC30B): Directly controls the product and provides power to the load.
For detailed wiring diagrams, please refer to the following figures:
Figure 6: Comprehensive wiring diagrams for AHC30A and AHC30B models. Figures 1 and B1 show direct control. Figures 2, 3, B2, and B3 show control with AC contactors for higher loads.
Important: The load capacity for direct control is 25A. If the load exceeds 4.5kW, it must be controlled via AC contactors (e.g., CJX1/LC1/CJT1).
6. Operating Instructions
6.1 Programming Weekly Schedule (18 ON/OFF)
The timer allows for up to 18 ON/OFF programs per week. Follow these steps to set your desired schedule:
| Step | Key | Programming Action |
|---|---|---|
| 1 | Press 'P' | Set the time of the first opening. |
| 2 | Press 'H+' / 'M+' | Display (1NO--:--), enter the time of first opening, adjust hours, adjust minutes. |
| 3 | Press 'D+' | Choose a certain day of the week. To open every day, select all (MO TU WE TH FR SA SU). |
| 4 | Press 'P' | Set the time of the first closing. |
| 5 | Press 'H+' / 'M+' | Display (1OFF--:--), enter the first shutdown time, adjust hours, adjust minutes. |
| 6 | Press 'D+' | Choose a certain day of the week. To close every day, select all (MO TU WE TH FR SA SU). |
| 7 | Repeat steps 2-6 | Set 2-18 ON/OFF times. |
| 8 | Press 'P' | End programming. |
Note: If you do not need all 18 settings, press the 'P' key to skip to the end.
To check your settings, press the 'P' button. If you need to clear a redundant program group, navigate to it in the timing settings and press 'MANUAL'. The screen will display '--:--' (not 00:00).
6.2 Countdown Settings
- To enter countdown mode, hold down the 'P' key, then hold down the 'D+' key and press both keys for 3 seconds. The display will show 'd0:00'.
- Set the countdown time: Hold down 'D+' and press 'H+' to adjust hours, and 'M+' to adjust minutes.
- To start the countdown, press 'MANUAL'.
- To reset to 0 halfway, press the 'RESET' button.
- To exit countdown mode, hold down the 'P' button, then press the 'D+' button for 3 seconds.
6.3 Ring Setting (Short Duration Switching)
This feature allows for short duration switching, useful for applications like an electric bell. When the timing is set, and the ON and OFF times are the same (e.g., 8:00 ON and 8:00 OFF), the timer will switch on for 10 seconds and then stop. This is ideal for momentary actions.
6.4 Manual Control
Press the 'MANUAL' button to temporarily turn the output ON or OFF. The display will show 'ON' or 'OFF'. When 'ON AUTO' or 'AUTO OFF' is displayed, the timer is in automatic timing state. The timing will not execute immediately but will automatically open and close at the next programmed time node.
7. Maintenance
- Battery Replacement: The timer includes a CR2032 lithium battery for power reserve (up to 3 years). If the battery is depleted, it can be replaced via the accessible compartment on the back of the unit.
- Cleaning: Clean the timer with a soft, dry cloth. Do not use harsh chemicals or abrasive cleaners.
- Environmental Conditions: Avoid exposing the timer to extreme temperatures, high humidity, or corrosive substances to ensure optimal performance and longevity.
8. Troubleshooting
Figure 7: Quick troubleshooting guide.
- Lid falls off: Please reinstall the clear protective lid.
- Screen not displaying: Press the 'RESET' button.
- Screen still not displaying (for 12V or 24V type): Charge the unit for 12 hours, then try pressing the 'RESET' button again.
- Programming issues / disorderly display: This can often be caused by electronic dry scratch. After eliminating the dry torsion source, perform a reset to initialize the timer.
- Functions 3 and 4 cannot be used at the same time: The timer has certain operational limitations; ensure you are not attempting to use incompatible functions simultaneously.
- Timing settings: Ensure your timing settings are ordered correctly (e.g., from morning to afternoon, then evening, then night) to avoid conflicts.
9. User Tips
- While the internal battery provides memory, if it's completely flat and there's a power outage, you might need to re-program the timer.
- The programming instructions can be challenging for first-time users; consider watching online tutorials for visual guidance if needed.
- The accessible battery compartment makes replacing the CR2032 battery straightforward when necessary.
- This timer is highly effective for managing weekly ON/OFF schedules for various devices.
10. Frequently Asked Questions (FAQ)
- Q: Is this timer compatible with 110 volts?
- A: Yes, the DIANQI AHC30A/AHC30B timer supports AC110V, as well as AC220V, DC12V, DC24V, and DC48V.
11. Warranty and Support
For detailed warranty information and further technical support, please refer to the official product documentation. A comprehensive user manual in PDF format is available for download at: User Manual (PDF).